Skip to main content

Rheological Basis of Magnetic Resonance Elastography

  • Chapter
Nano/Micro Science and Technology in Biorheology
  • 764 Accesses

Abstract

Magnetic resonance elastography (MRE) has been invented to measure the elastic properties of the living body on the basis of magnetic resonance imaging. From the viewpoint of medical practice, MRE is regarded as a palpation method. MRE has the advantage over other types of elastography in that the stiffness in all areas of the living body including deep areas inaccessible to the physician’s hand can be measured quantitatively in principle. Hence, by MRE, a complete viscoelastic map of the living body can be obtained. This advantage indicates that MRE is a powerful tool for determining the viscoelastic structures of nonuniform gels beyond the field of medicine. Unfortunately, the present MRE devices cannot perfectly realize the potential ability of the idea of MRE. Further improvements of the instruments for the MRE system and of the analysis algorithm for measured MRE data are necessary. Toward the construction of an ideal MRE system, we are trying to introduce the concept of rheology in MRE and to develop a purely theoretical approach to MRE. We consider what kind of physical quantity is actually measured and what kind of principle connects the measured quantities and the viscoelastic properties of the living body. The amplitude of a steady transverse wave excited in the living body is measured by MRE. The viscoelastic properties of the living body are described in terms of the Voigt model. The relationship between the viscoelastic parameters and the amplitude of the transverse wave is shown. The reconstruction formula of the map of the viscoelastic parameters from the data of the measured quantity is derived. The theoretical base of transverse wave excitation by a longitudinal wave, which enables us to measure the rigidity in deep areas practically, is also developed. A method of measuring the stiffness of a uniaxial system is introduced.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. For a recent review, see Mariappan YK, Glaser K.J, Ehman RL (2010) Magnetic resonance elastography: a review. Clin Anat 23:497–511

    Google Scholar 

  2. Muthupillai R, Lomas DJ, Rossman PJ, Greenleaf JF, Manduca A, Ehman RL (1995) Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science 269:1854–1857

    Article  CAS  PubMed  Google Scholar 

  3. For a review, see Parker KJ, Doyley MM, Rubens DJ (2011) Imaging the elastic properties of tissue: the 20 year perspective. Phys Med Biol 56:R1–R29

    Google Scholar 

  4. Uffmann K, Ladd ME (2008) Actuation systems for MR elastography. IEEE Eng Med Biol 27:28–34

    Article  Google Scholar 

  5. Manduca A, Oliphant TE, Dresner MA, Mahowald JL, Kruse SA, Amromin E, Felmlee JP, Greenleaf JF, Ehman RL (2001) Magnetic resonance elastography: non-invasive mapping of tissue elasticity. Med Image Anal 5:237–254

    Article  CAS  PubMed  Google Scholar 

  6. As an example, it is noted that diagnostic accuracy of MRE for assessing hepatic fibrosis has been verified. See Yin M, Talwalker JA, Glaser KJ, Manduca A, Grimm RC, Rossman PJ, Fidler JL, Ehman RL (2007) Assessment of hepatic fibrosis with magnetic resonance elastography. Clin Gastroenterol Hepatol 5:1207–1213

    Google Scholar 

  7. Suga M, Aga T, Minato K (2004) Development of a magnetic resonance elastic microscope system. Proc 26th Annu Int Conf IEEE EMBS: 1025–1027

    Google Scholar 

  8. Tadano S, Fujisaki K, Suzuki H, Takao S, Suga M, Kajiwara I, Yamamoto T, Jiang Y, Nakamura G (2012) Excitation system for magnetic resonance elastography using micro MRI. J Biomech Sci Eng 7:463–474

    Article  Google Scholar 

  9. Landau LD, Lifshitz EM (1976) Mechanics, 3rd edn (trans: Sykes JB, Bell JS). Elsevier, Amsterdam, §8

    Google Scholar 

  10. Landau LD, Lifshitz EM (1970) Theory of elasticity, 2nd edn (trans: Sykes JB, Reid WH). Pergamon, Oxford, §10

    Google Scholar 

  11. Landau LD, Lifshitz EM (1970) Theory of elasticity, 2nd edn (trans: Sykes JB, Reid WH). Pergamon, Oxford, §34

    Google Scholar 

  12. Goldstein H (1980) Classical mechanics, 2nd edn. Addison-Wesley, Cambridge, MA, pp 21–24

    Google Scholar 

  13. Suga M, Miura H, Fujiwara T, Yamamoto T, Tanaka T, Yu Q, Arai K, Gong JP, Nakamura G, Ikehira H, Obata T (2009) Inversion algorithm by integral type reconstruction formula for magnetic resonance elastography. Proc Int Soc Magn Reson Med 17:2506

    Google Scholar 

  14. Suga M, Obata T, Hirano M, Tanaka T, Ikehira H (2007) Magnetic resonance elastography to observe deep areas. Proc 29th Annu Int Conf IEEE EMBS: 2599–2602

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takao Yamamoto .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer Japan

About this chapter

Cite this chapter

Yamamoto, T. (2015). Rheological Basis of Magnetic Resonance Elastography. In: Kita, R., Dobashi, T. (eds) Nano/Micro Science and Technology in Biorheology. Springer, Tokyo. https://doi.org/10.1007/978-4-431-54886-7_7

Download citation

Publish with us

Policies and ethics