Skip to main content

Clipping Device with a Clear Liquid-Flushing Endoscope Equipping Wide View Coaxial Nozzle for Edge-to-Edge Repair Surgery without Heart-Lung Machine

  • Conference paper
Book cover Computer Aided Surgery

Abstract

We developed clipping device that could carry out edge-to-edge repair through endoscopic observation of the intracardiac valves, without using a heart-lung machine. One is a clear liquid-flushing endoscope which equipped coaxial round jet nozzle to observe φ8-mm area, called “wide view coaxial nozzle”. The other one is a clipping mechanism to carry out edge-to-edge repair without using a heart-lung machine. The clipping device was developed with the clear liquid-flushing endoscope which equipped wide view coaxial nozzle and evaluated the performance of this clipping device with an in vivo experiment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Masamune, K., Horiuchi, T., Mizutani, M., Yamashita, H., Tsukihara, H., Motomura, N., Takamoto, S., Liao, H., Dohi, T.: Novel Endoscope System with Plasma Flushing for Off-Pump Cardiac Surgery. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009, Part I. LNCS, vol. 5761, pp. 451–458. Springer, Heidelberg (2009)

    Chapter  Google Scholar 

  2. Horiuchi, T., et al.: Endoscope system with plasma flushing and coaxial round jet nozzle for off-pump cardiac surgery. Surgical Endoscopy 25(7), 2296–2301 (2011)

    Article  MathSciNet  Google Scholar 

  3. Timek, T.A., et al.: Mitral annular size predicts Alfieri stitch tension in mitral edge-to-edge repair. J. Heart Valve Dis. 13(2), 165–173 (2004)

    Google Scholar 

  4. Linte, C.A., et al.: An augmented reality environment for image-guidance of off-pump mitral valve implantation. In: Proc. SPIE International Symposium on Medical Imaging, San Diego, CA, February 17-22, pp. 6509–6522 (2007)

    Google Scholar 

  5. Horiuchi, T., et al.: Clipping device with endoscope and plasma-flushing system for intracardiac off-pump surgery. Journal of Japan Society of Computer Aided Surgery 12(3), 384–385 (2010)

    MathSciNet  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer Tokyo

About this paper

Cite this paper

Horiuchi, T., Masamune, K., Tsukihara, H., Motomura, N., Kuwana, K., Dohi, T. (2012). Clipping Device with a Clear Liquid-Flushing Endoscope Equipping Wide View Coaxial Nozzle for Edge-to-Edge Repair Surgery without Heart-Lung Machine. In: Dohi, T., Liao, H. (eds) Computer Aided Surgery. Proceedings in Information and Communications Technology, vol 3. Springer, Tokyo. https://doi.org/10.1007/978-4-431-54094-6_5

Download citation

  • DOI: https://doi.org/10.1007/978-4-431-54094-6_5

  • Publisher Name: Springer, Tokyo

  • Print ISBN: 978-4-431-54093-9

  • Online ISBN: 978-4-431-54094-6

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics