Advertisement

Clinical Experience with Ceramic on Ceramic in the USA

  • Jonathan P. Garino
Conference paper
Part of the Ceramics in Orthopaedics book series (CIO)

Abstract

Ceramic on Ceramic total hip arthroplasty (THR) has had a very long history as a low wear bearing material. With initial problems related to primarily fixation. That problem seemed to be solved with the advent of reliable cementless components, and the uncoupling of bearing and fixation functions. In the United States, 11 years have now passed since the first Food and Drug Administration (FDA) approved studies began, and four years have elapsed since the FDA approved the first Ceramic-Ceramic hip replacements for general use. Although the results of these multiple studies have continued to demonstrate the superior wear bearings of ceramics, the advent of highly cross-linked polyethylene, the relative lack of liner and ball head options, the occasional fracture, and now the report of an occasional squeaking hip have impeded more robust acceptance of these advanced bearing devices.

Keywords

Alumina Ceramic Hemispherical Shell Ceramic Bearing Ball Head Ceramic Fracture 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Sedel, L.; Nizard, R.; Bizot, P.; and Meunier, A.: Perspective on a 20-year experience with ceramic-on-ceramic articulation in total hip replacement. Semin Arthroplasty, 9(2): 123–134, 1998.Google Scholar
  2. 2.
    Murphy; SB; Ecker, T; Tannast, M; Bierbaum, B; Garino, J; Howe, J; Hume, E; Jones, R; Keggi, K; Kress, K; Phillips, D; Zann, R: Experience in the United States with Alumina Ceramic-Ceramic Total Hip Arthroplasty. Semin Arthroplasty, 17:120–124, 2006.Google Scholar
  3. 3.
    Heck, DA; Partridge, CM; Rueben, JD, et al: Prosthetic component failures in THR. J Arthroplasty: 10:575–580, 1995.PubMedCrossRefGoogle Scholar
  4. 4.
    D’antonio, J; Capello, W; Beirbaum, B; Manley, M; Naughton, MB: Ceramic-Ceramic bearings for total hip Arthroplasty: 5–9 year follow-up. Semin Arthroplasty, 17: 146–152, 2006.CrossRefGoogle Scholar
  5. 5.
    D’Antonio, J: Ceramic Fractures: Past and Present. Open meeting of the Hip Society, San Diego, February 17, 2007.Google Scholar

Copyright information

© Steinkopff Verlag 2007

Authors and Affiliations

  • Jonathan P. Garino
    • 1
  1. 1.Department of Orthopedic Surgery Cupp building first floorUniversity of PennsylvaniaPhiladelphiaUSA

Personalised recommendations