Skip to main content

Use of Modular Femoral Stem combined with large Diameter Femoral Head in Alumina-on-Alumina Total Hip Arthroplasty

  • Conference paper
Bioceramics and Alternative Bearings in Joint Arthroplasty

Part of the book series: Ceramics in Orthopaedics ((CIO))

  • 945 Accesses

Abstract

While the clinical use of alumina-on-alumina bearings in total hip arthroplasty has demonstrated excellent clinical results with a low rate of osteolysis, relatively few head and liner options of alumina implants compared with conventional metal-on-polyethylene articulations continue to be one potential disadvantage that may often lead to impingement or dislocation after total hip arthroplasty. We hypothesized that a modular femoral stem that offered a variety of intraoperative adjustment options for producing appropriate femoral offset, length, and version would be favored to optimize stability following alumina-on-alumina total hip arthroplasty. It was also postulated that larger diameter femoral heads that allow for a greater range of motion prior to prosthetic impingement could reduce the risk of dislocation following alumina-on-alumina total hip arthroplasty. When reviewing a consecutive series of 136 alumina-on-alumina total hip arthroplasties performed with use of the S-ROM modular stem combined with 32-mm femoral head at our institution, we have found no ceramic fractures or bearing failures, and only one early postoperative dislocation that resolved with closed reduction was identified during the short follow-up period. Given the extremely low wear rates of alumina-on-alumina bearings even with larger femoral head diameters, our findings may increase potential for use of 32-mm femoral head combined with the S-ROM modular stem in both straightforward and complex total hip arthroplasties that are at high risk for prosthetic impingement or dislocation.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res. 2000; 379:22–28.

    Article  PubMed  Google Scholar 

  2. Nizard R, Sedel L, Hannouche D, Hamadouche M, Bizot P. Alumina pairing in total hip replacement. J Bone Joint Surg Br. 2005; 87:755–758.

    Article  PubMed  CAS  Google Scholar 

  3. Bizot P, Hannouche D, Nizard R, Witvoet J, Sedel L. Hybrid alumina total hip arthroplasty using a press-fit metal backed socket in patients younger than 55 years: a six-to 11-year evaluation. J Bone Joint Surg Br. 2004; 86:190–194.

    Article  PubMed  CAS  Google Scholar 

  4. Yoo JJ, Kim YM, Yoon KS, Koo KH, Song WS, Kim HJ. Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am. 2005; 87:530–535.

    Article  PubMed  Google Scholar 

  5. D’Antonio J, Capello W, Manley M, Naughton M, Sutton K. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res. 2005; 436:164–171.

    Article  PubMed  Google Scholar 

  6. Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004; 429:73–79.

    Article  PubMed  Google Scholar 

  7. Shon WY, Baldini T, Peterson MG, Wright TM, Salvati EA. Impingement in total hip arthroplasty: a study of retrieved acetabular components. J Arthroplasty. 2005; 20:427–435.

    Article  PubMed  Google Scholar 

  8. Hasegawa M, Sudo A, Uchida A. Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component. J Bone Joint Surg Br.2006; 88:877–882.

    Article  PubMed  CAS  Google Scholar 

  9. Park YS, Hwang SK, Choy WK, Kim YS, Moon YW, Lim SJ. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am. 2006; 88:780–787.

    Article  PubMed  Google Scholar 

  10. Fisher J, Jin Z, Tipper J, Stone M, Ingham E. Tribology of alternative bearings. Orthop Relat Res. 2006; 453:25–34.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Steinkopff Verlag

About this paper

Cite this paper

Park, YS., Moon, YW., Lim, SJ. (2007). Use of Modular Femoral Stem combined with large Diameter Femoral Head in Alumina-on-Alumina Total Hip Arthroplasty. In: Chang, JD., Billau, K. (eds) Bioceramics and Alternative Bearings in Joint Arthroplasty. Ceramics in Orthopaedics. Steinkopff. https://doi.org/10.1007/978-3-7985-1783-7_15

Download citation

  • DOI: https://doi.org/10.1007/978-3-7985-1783-7_15

  • Publisher Name: Steinkopff

  • Print ISBN: 978-3-7985-1782-0

  • Online ISBN: 978-3-7985-1783-7

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics