Summary

A new method for external stereotactic focal irradiation of three-dimensional irregular target volumes is proposed. In this method the target is irradiated by a linear accelerator set in various angular positions around the isocenter. During the irradiation the target is translated in a direction perpendicular to the beam. By controlling the velocity of the translation it is possible to modify the configuration of therapeutic isodoses so as to make them follow the borders of the target.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Alderson SW, Lanzl LH, Rollins M, Spira J (1962) An instrumented phantom system for analog computation of treat-ment plans. Am J Roentgenol 87: 185–190

    CAS  Google Scholar 

  2. Arndt J, Backlund EO, Larsson B, Leksell L, Noren G, Rosander K, Rahn T, Sarby B, Steiner L, Wennerstrand J (1979) Stereotactic irradiations of intracranial structures. Physical and dosimetric considerations. In: Szikla G (ed) Stereotactic cerebral irradiations. Elsevier, Amsterdam, pp 81–92

    Google Scholar 

  3. Betti O, Derechinski V (1983) Irradiation stéréotaxique multifaisceaux. Neurochir 29: 295–298

    CAS  Google Scholar 

  4. Colombo F, Casentini L, Benedetti A, Pozza F, Peserico L (1984) Biopsia e radioterapia stereotassica dei gliomi cerebrali. Minerva Medica 75: 73–77

    Google Scholar 

  5. Colombo F, Benedetti A, Pozza F, Avanzo RC, Chierego G, Marchetti C, Zanardo A (1985) Stereotactic external irradiation by linear accelerator. Neurosurg 16: 154–160

    Article  CAS  Google Scholar 

  6. Colombo F, Benedetti A, Pozza F, Avanzo RC, Chierego G, Marchetti C (1985) Stereotactic radiosurgery utilizing a linear accelerator. Appi Neurophysiol 48: 133–145

    CAS  Google Scholar 

  7. Heifetz MD, Wexler M, Thompson R (1984) Single beam radiotherapy knife. J Neurosurg 60: 814–818

    Article  CAS  PubMed  Google Scholar 

  8. Katz M (1978) Principles and technique of image reconstruction with CT. In: Weisberg LA, Nice C, Katz M (eds) Cerebral computer tomography—a text atlas. Saunders, Philadelphia, pp 10–27

    Google Scholar 

  9. Kelly PJ, Bruce AK, Goerss S (1984) Computer simulation for the stereotactic placements of interstitial radionuclide sources into computer tomography defined tumor volumes. Neurosurg 14: 442–446

    Article  CAS  Google Scholar 

  10. Leksell L (1971) Stereotaxy and radiosurgery: an operative system. Ch C Thomas, Springfield, 111

    Google Scholar 

  11. Mundinger F (1979) Rationale and methods for interstitial Ir 192 brachycurietherapy and Ir 192 and I 125 protracted long term irradiations. In: Szikla G (ed) Stereotactic cerebral irradiations. Elsevier, Amsterdam, pp 101–117

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Springer-Verlag

About this paper

Cite this paper

Colombo, F. et al. (1987). New Technique for Three-Dimensional Linear Accelerator Radiosurgery. In: Gybels, J., Hitchcock, E.R., Meyerson, B., Ostertag, C., Rossi, G.F. (eds) Advances in Stereotactic and Functional Neurosurgery 7. Acta Neurochirurgica Supplementum, vol 39. Springer, Vienna. https://doi.org/10.1007/978-3-7091-8909-2_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-7091-8909-2_11

  • Publisher Name: Springer, Vienna

  • Print ISBN: 978-3-7091-8911-5

  • Online ISBN: 978-3-7091-8909-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics