Skip to main content

Neue Dimensionen der Biosensorik

  • Chapter
Bionik

Zusammenfassung

Die Kommunikation in der belebten Welt beruht auf Wechselwirkungen, die eine hohe Spezifität besitzen.

Der Autor bedankt sich bei der DFG für die Förderung der Forschungsarbeiten im Rahmen des INK 16A1-1.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literaturverzeichnis

  • Alberts, B. (1986): Molekularbiologie der Zelle, Weinheim (VCH).

    Google Scholar 

  • Ansell, R.J., Kriz, D. and Mosbach, K. (1996): Molecularly imprinted polymers for bioanalysis: chromatography, binding assays and biomimetic sensors. Current Opt. Biotechnol., 7, 89–94.

    Article  Google Scholar 

  • Armstrong, F.A. (1990): Probing metalloproteins by voltammetry. Structure and Bonding, 72, 137–221.

    Article  Google Scholar 

  • Bartlett, P.N., Booth, S., Caruana, D.J., Kilburn, J.D. and Santamaria, C. (1997): Modification of glucose oxidase by the covalent attachment of a tetrathiafulvalene derivative. Anal. Chem., 69, 734–742.

    Article  Google Scholar 

  • Bier, F.F. and Fürste, J.P. (1997): Nucleic acid based sensors. In: Scheller et al. (Ed.), Frontiers in biosensorics I. Fundamental aspects, Basel, (Birkhäuser), 96–120.

    Google Scholar 

  • Blackburn, G.F., Talley, D.B., Booth, P.M., Durfor, C.N., Martin, M.T., Napper, A.D. and Rees, A.R. (1990): Potentiometric biosensor employing catalytic antibodies as the molecular recognition element. Anal. Chem., 62, 2211–2216.

    Article  Google Scholar 

  • Bräuchle, C. (1991): Optical application of bacteriorhodopsin and its mutated variants. In: Advanced Materials, 3, 420–428.

    Google Scholar 

  • Degani, Y. and Heller, A. (1987): Direct electrochemical communication between chemically modified enzymes and metal electrodes. J. Phys. Chem., 91, 1285–1289.

    Article  Google Scholar 

  • Eigen, M. (1986): The physics of molecular evolution. Chemica Scripta, 268, 13–26.

    Google Scholar 

  • Ellington, A.D. and Szostak, J.W. (1990): In vitro selection of RNA molecules that bind specific ligands. Nature, 346, 818–822.

    Article  Google Scholar 

  • Fromherz, P., Offenhäuser, A., Vetter, T. and Weis, J. (1991): A neurone-silicon junction: A Retzius cell leech on an insulated-gate field-effect transistor. Science, 252, 1290–1293.

    Article  Google Scholar 

  • Gorton, L., Jönsson-Pettersson, G., Csöregi, E., Johansson, K., Dominguez, E. and Marko-Varga, G. (1992): Amperometric biosensors based on an apparent direct electron transfer between electrodes and immobilized peroxidases. Analyst, 117, 1235–1241.

    Article  Google Scholar 

  • Hall, E. (1991): Biosensors. London (Prentice-Hall International (UK) Limited).

    Google Scholar 

  • Hansen, P.-D. and Usedom, A.v. (1997): New biosensors for environmental analysis. In: Scheller et al. (Ed.), Frontiers in bisensorics II. Practical applications, Basel, (Birkhäuser), 109–120.

    Google Scholar 

  • Hilvert, D. (1993): Antibody catalysis of carbon-carbon bond formation and cleavage. Acc. Chem. Res., 26, 552–558.

    Article  Google Scholar 

  • Ikeda, T., Matsushita, F. and Senda, M. (1991): Amperometric fructose sensor based on direct bioelectrocatalysis. Biosensors Bioelectronics, 6, 299–304.

    Article  Google Scholar 

  • Ikeda, T. (1997): Direct redox communication between enzymes and electrodes. In: Scheller et al. (Ed.), Frontiers in biosensorics I. Fundamental aspects, Basel, (Birkhäuser), 243–266.

    Chapter  Google Scholar 

  • Katakis, I. and Heller, A. (1997): Electron transfer via redox hydrogels between electrodes and enzymes. In: Scheller et al. (Ed.), Frontiers in biosensorics I. Fundamental aspects, Basel, (Birkhäuser), 227–241.

    Google Scholar 

  • Lerner, R.A., Benkovic, S.J. and Schultz, P.G. (1991): At the crossroads of chemistry and immunology: Catalytic antibodies. Science, 252, 659–667.

    Article  Google Scholar 

  • Li Jiang, Mc Neil, C.J. and Cooper, J.M. (1995): Direct electron transfer reactions of glucose oxidase immobilized at a self-assembled monolayer. J.Chem.Soc., Chem. Commun., 1293–1295.

    Google Scholar 

  • Luedi, H. (1997): Challenges in the development of (bio) chemical sensors for whole blood medical diagnostic applications. In: Scheller et al. (Ed.), Frontiers in biosensorics II. Practical applications, Basel, (Birkhäuser), 141–148.

    Chapter  Google Scholar 

  • Macnab, R.N. and Parkinson, J.S. (1991): Genetic analysis of the bacterial flagellum. Trends in Genetics, 7, 196–200.

    Google Scholar 

  • McNeil, C.J., Greenough, K.R., Weeks, P.A., Self, C.H. and Cooper, J.M. (1992): Electrochemical sensors for direct reagentless measurement of superoxide production by human neutrophils. Free Rad. Res. Comms., 17, 6, 399–406.

    Article  Google Scholar 

  • Martin, M.T. (1996): Commercially valuable catalytic antibodies: The life to come. DDT, 1, 6, 239–245.

    Google Scholar 

  • Owicki, J.C. and Parce, J.W. (1990): Bioassay with a microphysiometer. Natur, 344, 271–272.

    Article  Google Scholar 

  • Pfeiffer, D. (1997): Commercial biosensors for medical application. In: Scheller et al. (Ed.), Frontiers in biosensorics II. Practical applications, Basel, (Birkhäuser), 149–160.

    Chapter  Google Scholar 

  • Riedel, K. (1997): Microbial BOD sensors: Problems of practical use and comparison of sensor BOD and BOD5. In: Scheller et al. (Ed.), Frontiers in biosensorics II. Practical applications, Basel, (Birkhäuser), 99–108.

    Chapter  Google Scholar 

  • Riklin, A., Katz, E., Willner, I., Stocker, A. and Bückmann, A.F. (1995): Improving enzyme-electrode contacts by redox modification of cofactors. Nature, 376, 672–675.

    Article  Google Scholar 

  • Scheller, F.W., Schubert, F. and Fedrowitz, J. (1997): Present state and frontiers in biosensorics. In: Scheller et al. (Ed.), Frontiers in biosensorics I. Fundamental aspects, Basel, (Birkhäuser), 1–9.

    Chapter  Google Scholar 

  • Schmidt, H.L., Schuhmann, W., Scheller, F.W. and Schubert, F. (1992): Specific features of biosensors. In: Göpel, W. (Ed.), Sensors, Weinheim (VCH), 719–817.

    Google Scholar 

  • Sugawara, M., Sato, H., Ozawa, T. and Umezawa, Y. (1997): Receptor based chemical sensing. In: Scheller et al. (Ed.), Frontiers in biosensorics I. Fundamental aspects, Basel, (Birkhäuser), 121–132.

    Chapter  Google Scholar 

  • Thévenot, D.R., Toth, K., Durst, R.A. and Wilson, G.S. (1996): News and Market Update. Biosensors & Bioelectronics, 11, 4, i.

    Article  Google Scholar 

  • Urban, G., Jobst, G., Aschauer, E., Tilado, O., Svasek, P. and Varahram, M. (1994): Performance of integrated glucose and lactate thin film microbiosensors for clinical analyzers. Sensor. Actuator. B, 1–3, 592–596.

    Article  Google Scholar 

  • Warsinke, A. (1997): Biosensors for food analysis. In: cheller et al. (Ed.), Frontiers in biosensorics II. Practical applications, Basel, (Birkhäuser), 120–139.

    Google Scholar 

  • Wilson, G., Zhang, Y., Reach, G., Moatti-Sirat, D., Poitout, V., Thevenot, D.R., Lemonnier, F. and Klein, J.-C. (1992): Progress toward the development of implantable sensor for glucose. Clin. Chem., 38, 1613–1617.

    Google Scholar 

  • Wollenberger, U., Schubert, F., Pfeiffer, D. and Scheller, W.F. (1993): Enhancing biosensor performance using multienzyme systems. TIBTECH, Juni/11, 255–262.

    Article  Google Scholar 

  • Wollenberger, U., Hintsche, R. and Scheller, F.W. (1995): Biosensors for analytical microsystems. Microsystem Technology, 1, 275–283.

    Article  Google Scholar 

  • Wulff, G. (1986): Molecular recognition in polymers prepared by imprinting with templates. In: Ford, W.T. (Ed.), Polymeric reagents and catalyst. ACS Symposium series, American Chemical Society, Washington, D.C., 186–230.

    Chapter  Google Scholar 

  • Wulff, G. (1995): Molecular imprinting in cross-linked materials with the aid of molecular templates.- A way towards artificial antibodies. Angew. Chem. Int. Ed. Engl., 34, 1812–1832.

    Article  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 B. G. Teubner Stuttgart

About this chapter

Cite this chapter

Scheller, F.W. (1998). Neue Dimensionen der Biosensorik. In: von Gleich, A. (eds) Bionik. Vieweg+Teubner Verlag, Wiesbaden. https://doi.org/10.1007/978-3-663-01343-3_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-663-01343-3_12

  • Publisher Name: Vieweg+Teubner Verlag, Wiesbaden

  • Print ISBN: 978-3-519-06195-3

  • Online ISBN: 978-3-663-01343-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics