Advertisement

Non-sliding (Static) Knots

  • Elmar Herbst
  • Masahito Yoshida
  • Gregory Gasbarro
  • Stephenson Ikpe
  • Volker Musahl
Chapter

Abstract

Technical advances in arthroscopic surgery have popularized the use of sliding knots in favor of traditional non-sliding or static knots. This preference may be a result of technical ease of tying through a cannula, as the surgeon can secure knots without switching post limbs. However, it has been shown that non-sliding knots such as the square or the Revo knot provide better loop and knot security. Furthermore, sliding knots cannot be used with suture anchors lacking an eyelet or in situations where it is difficult to slide sutures through soft tissue. Another indication for static knot tying is for repairs of degenerative soft tissue. In these cases, the suture may cause further damage to the tissue while advancing the knot. When performing a non-sliding knot, one has to take into consideration that the knot has to be seated properly before adding reversed half hitches to avoid premature knot locking resulting insufficient loop and knot security.

References

  1. 1.
    Barber FA, et al. Cyclic load and failure behavior of arthroscopic knots and high strength sutures. Arthroscopy. 2009;25(2):192–9.CrossRefPubMedGoogle Scholar
  2. 2.
    Baumgarten KM, et al. An in vitro analysis of the mechanical properties of 16 arthroscopic knots. Knee Surg Sports Traumatol Arthrosc. 2008;16(10):957–66.CrossRefPubMedGoogle Scholar
  3. 3.
    Clark RR, et al. Biomechanical performance of traditional arthroscopic knots versus slippage-proof knots. Arthroscopy. 2013;29(7):1175–81.CrossRefPubMedGoogle Scholar
  4. 4.
    Elkousy HA, et al. A biomechanical comparison of arthroscopic sliding and sliding-locking knots. Arthroscopy. 2005;21(2):204–10.CrossRefPubMedGoogle Scholar
  5. 5.
    Ilahi OA, et al. Cyclic testing of arthroscopic knot security. Arthroscopy. 2004;20(1):62–8.CrossRefPubMedGoogle Scholar
  6. 6.
    Lo IK, et al. Arthroscopic knots: determining the optimal balance of loop security and knot security. Arthroscopy. 2004;20(5):489–502.CrossRefPubMedGoogle Scholar
  7. 7.
    Lo IK, et al. A comparison of knot security and loop security in arthroscopic knots tied with newer high-strength suture materials. Arthroscopy. 2010;26(9 Suppl):S120–6.CrossRefPubMedGoogle Scholar
  8. 8.
    Riboh JC, et al. Shortcuts in arthroscopic knot tying: do they affect knot and loop security? Am J Sports Med. 2012;40(7):1572–7.CrossRefPubMedGoogle Scholar
  9. 9.
    Rodes SA, et al. Performance comparison of a pretied suture knot with three conventional arthroscopic knots. Arthroscopy. 2015;31(11):2183–90.CrossRefPubMedGoogle Scholar
  10. 10.
    Hassinger SM, et al. Biomechanical characteristics of 10 arthroscopic knots. Arthroscopy. 2006;22(8):827–32.CrossRefPubMedGoogle Scholar
  11. 11.
    Kim SH, et al. Significance of the internal locking mechanism for loop security enhancement in the arthroscopic knot. Arthroscopy. 2001;17(8):850–5.CrossRefPubMedGoogle Scholar
  12. 12.
    Trimbos JB. Security of various knots commonly used in surgical practice. Obstet Gynecol. 1984;64(2):274–80.PubMedGoogle Scholar
  13. 13.
    Loutzenheiser TD, et al. Optimizing arthroscopic knots using braided or monofilament suture. Arthroscopy. 1998;14(1):57–65.CrossRefPubMedGoogle Scholar
  14. 14.
    Nottage WM, Lieurance RK. Arthroscopic knot typing techniques. Arthroscopy. 1999;15(5):515–21.CrossRefPubMedGoogle Scholar
  15. 15.
    Elkousy H, et al. The arthroscopic square knot: a biomechanical comparison with open and arthroscopic knots. Arthroscopy. 2006;22(7):736–41.CrossRefPubMedGoogle Scholar
  16. 16.
    Swan KG Jr, et al. Arthroscopic suture material and knot type: an updated biomechanical analysis. Am J Sports Med. 2009;37(8):1578–85.CrossRefPubMedGoogle Scholar
  17. 17.
    Ilahi OA, et al. Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid. Am J Sports Med. 2008;36(12):2407–14.CrossRefPubMedGoogle Scholar
  18. 18.
    Baumgarten KM, Wright RW. Ease of tying arthroscopic knots. J Shoulder Elb Surg. 2007;16(4):438–42.CrossRefGoogle Scholar
  19. 19.
    Burkhart SS, Lo IK. Arthroscopic rotator cuff repair. J Am Acad Orthop Surg. 2006;14(6):333–46.CrossRefPubMedGoogle Scholar
  20. 20.
    Burkhart SS, et al. Loop security as a determinant of tissue fixation security. Arthroscopy. 1998;14(7):773–6.CrossRefPubMedGoogle Scholar
  21. 21.
    Neuhofer S, et al. Surgical knot tightening: how much pull is necessary? Knee Surg Sports Traumatol Arthrosc. 2014;22(11):2849–55.CrossRefPubMedGoogle Scholar
  22. 22.
    Dahl KA, et al. Biomechanical characteristics of 9 arthroscopic knots. Arthroscopy. 2010;26(6):813–8.CrossRefPubMedGoogle Scholar
  23. 23.
    Chan KC, Burkhart SS. How to switch posts without rethreading when tying half-hitches. Arthroscopy. 1999;15(4):444–50.CrossRefPubMedGoogle Scholar
  24. 24.
    Chan KC, et al. Optimization of stacked half-hitch knots for arthroscopic surgery. Arthroscopy. 2001;17(7):752–9.CrossRefPubMedGoogle Scholar
  25. 25.
    Livermore RW, et al. Knot security, loop security, and elongation of braided polyblend sutures used for arthroscopic knots. Am J Orthop (Belle Mead NJ). 2010;39(12):569–76.Google Scholar
  26. 26.
    Meier JD, Meier SW. Over-pointing technique: an approach to past-pointing arthroscopic knots on alternating suture posts without alternating the knot pusher. Arthroscopy. 2007;23(12):1358.e1351–3.CrossRefGoogle Scholar
  27. 27.
    Burkhart SS, et al. Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be? Arthroscopy. 2000;16(2):202–7.CrossRefPubMedGoogle Scholar
  28. 28.
    Mishra DK, et al. Elongation of arthroscopically tied knots. Am J Sports Med. 1997;25(1):113–7.CrossRefPubMedGoogle Scholar
  29. 29.
    Delimar D. A secure arthroscopic knot. Arthroscopy. 1996;12(3):345–7.CrossRefPubMedGoogle Scholar
  30. 30.
    Harryman DT II, et al. Arthroscopic labral repair to the glenoid rim. Arthroscopy. 1994;10(1):20–30.CrossRefPubMedGoogle Scholar
  31. 31.
    Richmond JC. A comparison of ultrasonic suture welding and traditional knot tying. Am J Sports Med. 2001;29(3):297–9.CrossRefPubMedGoogle Scholar
  32. 32.
    Snyder SJ. Technique of arthroscopic rotator cuff repair using implantable 4-mm Revo suture anchors, suture shuttle relays, and no. 2 nonabsorbable mattress sutures. Orthop Clin North Am. 1997;28(2):267–75.CrossRefPubMedGoogle Scholar
  33. 33.
    Lieurance RK, et al. Failure characteristics of various arthroscopically tied knots. Clin Orthop Relat Res. 2003;408:311–8.CrossRefGoogle Scholar

Copyright information

© ESSKA 2018

Authors and Affiliations

  • Elmar Herbst
    • 1
  • Masahito Yoshida
    • 1
  • Gregory Gasbarro
    • 1
  • Stephenson Ikpe
    • 1
  • Volker Musahl
    • 1
  1. 1.Department of Orthopaedic Surgery, UPMC Center for Sports MedicineUniversity of PittsburghPittsburghUSA

Personalised recommendations