Abstract
With the rapid development of ±800 kV UHVDC power transmission technology, the demand of the power transmission projects of longer distance and larger capacity has been gradually emergent. So it is necessary to develop the UHVDC power transmission technology with higher voltage level. In this chapter, based on the above-mentioned researching method on the switching overvoltage of UHVDC system, using PSCAD/EMTDC and relying on the actual ±1100 kV and ±800 kV UHVDC Power Transmission Project, simulations on the overvoltage of the positions in the converter stations were carried out. And then, the internal overvoltage in the converter station of both ±1100 kV and ±800 kV UHVDC power transmission systems was contrasted. And the suggestion on insulation coordination of the converter stations in ±1100 kV UHVDC power transmission system is proposed. Finally, the contrast and discussion were carried out about the combination scheme for selection of double 12-pulse converters connected in series and triple 12-pulse converters connected in series.
References
Zhou H, Wang D. Overvoltage protection and insulation coordination for ±1100 kV UHVDC converter station. Power Syst Technol. 2012;36(9):1–8.
Wang D, Deng X, Zhou H, Chen X, Shen Y, Sun K. On the DC transient overvoltage in the converter stations of ±800 kV Xiluodu–Zhexi HVDC project. South Power Syst Technol. 2012;6(2):6–13.
Chen X, Zhou H, Wang D, Shen Y, Qian F, Zhou Z, Qiu W. Study on transient overvoltage of Zhexi converter station of ±800 kV DC power transmission project. Power Syst Technol. 2012;36(3):22–7.
Chen X, Tian J, Wang D, Yuan S, Zhou H. Analysis on overvoltage in renovated control and protection system for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2011;35(6):101–6.
Chen X, Zhou H, Wang D, Shen Y, Ding J, Qian F, Zhou Z, Qiu W. Insulation coordination for Zhexi converter station of ±800 kV DC power transmission project from Xiluodu to Zhexi. Power Syst Technol. 2012;36(2):7–12.
Wang D, Deng X, Zhou H, Chen X, Xu A, Shen Y. Research on converter valve overvoltage mechanism and calculation conditions of ±800 kV converter station (English Version). High Volt Eng. 2012;12:3189–97.
Chen X, Zhou H, Yuan S, Wang D, Tian J, Huang Z, Lu Y. Overvoltage mechanism of converter valves for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2012;36(3):88–94.
Yuan S, Wang D, Chen X, Huang Z, Lu Y, Tian J, Chen W, Sun K, Zhou H. Study on neutral-bus overvoltage mechanism of ±500 kV DC power transmission project from Tianshengqiao to Guangdong. Power Syst Technol. 2011;35(5):216–22.
Nie D, Ma W, Zheng J. Insulation coordination for ±800 kV UHVDC converter stations. High Volt Eng. 2006;9:75–9.
Zhou H, Chen X, Chen R, Wang D, Yuan S, Sun K. Analysis on insulation coordination scheme for ±800 kV DC converter station. Power Syst Technol. 2011;35(11):18–24.
Deng X, Wang D, Shen Y, Zhou H, Chen X, Sun K. DC switching overvoltage of ±1100 kV UHVDC converter station. Electric Power Autom Equip. 2014;34(1):141–7.
Deng X, Wang D, Shen Y, Zhou H, Chen X, Sun K. Main circuit parameter design of Zhundong-Sichuan ±1100 kV UHVDC power transmission project. Electric Power Autom Equip. 2014;34(4):133–40.
Zhou P, He H, Dai M, Wan L. Selection of arresters arrangement, parameters and apparatuses insulation levels for μ1 100 kV DC converter station. High Volt Eng. 2014;40(9):2871–84.
Nie D, Yuan Z. Research on insulation coordination for converter stations of ±800 kV UHVDC project from Xiangjiaba to Shanghai. Power Syst Technol. 2007;31(14):1–5.
Zhou P, Xiu M, Gu D, Dai M, Lou Y. Study on overvoltage protection and insulation coordination for ±800 kV HVDC transmission system. High Volt Eng. 2006;32(12):125–32.
Q/GDW 101-2003. Provisional technical code for design of 750 kV substations. 2003.
Huang Y, Li X, Rao H, Wen K, Tian F. Discussion on the insulation margin of thyristor valves for ±800 kV power transmission. South Power Syst Technol Res. 2006;2(6):23–7.
Nie D, Ma W, Li M. Insulation coordination for converter stations of UHVDC Project from Jinping to South Jiangsu. High Volt Eng. 2010;36(1):92–7.
Zhou H, Deng X, Wang D, Shen Y, Chen X, Sun K. Overvoltage Protection and insulation coordination for ±1100 kV UHVDC converter station (English Version). High Volt Eng. 2013;39(10):2477–84.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Zhejiang University Press, Hangzhou and Springer-Verlag GmbH Germany
About this chapter
Cite this chapter
Qiu, W., Zhou, H., Wang, D. (2017). Comparison of Overvoltage and Insulation Coordination of ±800 kV and ±1100 kV UHVDC Systems. In: Zhou, H., et al. Ultra-high Voltage AC/DC Power Transmission. Advanced Topics in Science and Technology in China. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54575-1_23
Download citation
DOI: https://doi.org/10.1007/978-3-662-54575-1_23
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-54573-7
Online ISBN: 978-3-662-54575-1
eBook Packages: EnergyEnergy (R0)