Skip to main content

Comparison of Overvoltage and Insulation Coordination of ±800 kV and ±1100 kV UHVDC Systems

  • Chapter
  • First Online:
Ultra-high Voltage AC/DC Power Transmission

Part of the book series: Advanced Topics in Science and Technology in China ((ATSTC))

  • 1127 Accesses

Abstract

With the rapid development of ±800 kV UHVDC power transmission technology, the demand of the power transmission projects of longer distance and larger capacity has been gradually emergent. So it is necessary to develop the UHVDC power transmission technology with higher voltage level. In this chapter, based on the above-mentioned researching method on the switching overvoltage of UHVDC system, using PSCAD/EMTDC and relying on the actual ±1100 kV and ±800 kV UHVDC Power Transmission Project, simulations on the overvoltage of the positions in the converter stations were carried out. And then, the internal overvoltage in the converter station of both ±1100 kV and ±800 kV UHVDC power transmission systems was contrasted. And the suggestion on insulation coordination of the converter stations in ±1100 kV UHVDC power transmission system is proposed. Finally, the contrast and discussion were carried out about the combination scheme for selection of double 12-pulse converters connected in series and triple 12-pulse converters connected in series.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  1. Zhou H, Wang D. Overvoltage protection and insulation coordination for ±1100 kV UHVDC converter station. Power Syst Technol. 2012;36(9):1–8.

    Google Scholar 

  2. Wang D, Deng X, Zhou H, Chen X, Shen Y, Sun K. On the DC transient overvoltage in the converter stations of ±800 kV Xiluodu–Zhexi HVDC project. South Power Syst Technol. 2012;6(2):6–13.

    Google Scholar 

  3. Chen X, Zhou H, Wang D, Shen Y, Qian F, Zhou Z, Qiu W. Study on transient overvoltage of Zhexi converter station of ±800 kV DC power transmission project. Power Syst Technol. 2012;36(3):22–7.

    Google Scholar 

  4. Chen X, Tian J, Wang D, Yuan S, Zhou H. Analysis on overvoltage in renovated control and protection system for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2011;35(6):101–6.

    Google Scholar 

  5. Chen X, Zhou H, Wang D, Shen Y, Ding J, Qian F, Zhou Z, Qiu W. Insulation coordination for Zhexi converter station of ±800 kV DC power transmission project from Xiluodu to Zhexi. Power Syst Technol. 2012;36(2):7–12.

    Google Scholar 

  6. Wang D, Deng X, Zhou H, Chen X, Xu A, Shen Y. Research on converter valve overvoltage mechanism and calculation conditions of ±800 kV converter station (English Version). High Volt Eng. 2012;12:3189–97.

    Google Scholar 

  7. Chen X, Zhou H, Yuan S, Wang D, Tian J, Huang Z, Lu Y. Overvoltage mechanism of converter valves for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2012;36(3):88–94.

    Google Scholar 

  8. Yuan S, Wang D, Chen X, Huang Z, Lu Y, Tian J, Chen W, Sun K, Zhou H. Study on neutral-bus overvoltage mechanism of ±500 kV DC power transmission project from Tianshengqiao to Guangdong. Power Syst Technol. 2011;35(5):216–22.

    Google Scholar 

  9. Nie D, Ma W, Zheng J. Insulation coordination for ±800 kV UHVDC converter stations. High Volt Eng. 2006;9:75–9.

    Google Scholar 

  10. Zhou H, Chen X, Chen R, Wang D, Yuan S, Sun K. Analysis on insulation coordination scheme for ±800 kV DC converter station. Power Syst Technol. 2011;35(11):18–24.

    Google Scholar 

  11. Deng X, Wang D, Shen Y, Zhou H, Chen X, Sun K. DC switching overvoltage of ±1100 kV UHVDC converter station. Electric Power Autom Equip. 2014;34(1):141–7.

    Google Scholar 

  12. Deng X, Wang D, Shen Y, Zhou H, Chen X, Sun K. Main circuit parameter design of Zhundong-Sichuan ±1100 kV UHVDC power transmission project. Electric Power Autom Equip. 2014;34(4):133–40.

    Google Scholar 

  13. Zhou P, He H, Dai M, Wan L. Selection of arresters arrangement, parameters and apparatuses insulation levels for μ1 100 kV DC converter station. High Volt Eng. 2014;40(9):2871–84.

    Google Scholar 

  14. Nie D, Yuan Z. Research on insulation coordination for converter stations of ±800 kV UHVDC project from Xiangjiaba to Shanghai. Power Syst Technol. 2007;31(14):1–5.

    Google Scholar 

  15. Zhou P, Xiu M, Gu D, Dai M, Lou Y. Study on overvoltage protection and insulation coordination for ±800 kV HVDC transmission system. High Volt Eng. 2006;32(12):125–32.

    Google Scholar 

  16. Q/GDW 101-2003. Provisional technical code for design of 750 kV substations. 2003.

    Google Scholar 

  17. Huang Y, Li X, Rao H, Wen K, Tian F. Discussion on the insulation margin of thyristor valves for ±800 kV power transmission. South Power Syst Technol Res. 2006;2(6):23–7.

    Google Scholar 

  18. Nie D, Ma W, Li M. Insulation coordination for converter stations of UHVDC Project from Jinping to South Jiangsu. High Volt Eng. 2010;36(1):92–7.

    Google Scholar 

  19. Zhou H, Deng X, Wang D, Shen Y, Chen X, Sun K. Overvoltage Protection and insulation coordination for ±1100 kV UHVDC converter station (English Version). High Volt Eng. 2013;39(10):2477–84.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wenqian Qiu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Zhejiang University Press, Hangzhou and Springer-Verlag GmbH Germany

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Qiu, W., Zhou, H., Wang, D. (2017). Comparison of Overvoltage and Insulation Coordination of ±800 kV and ±1100 kV UHVDC Systems. In: Zhou, H., et al. Ultra-high Voltage AC/DC Power Transmission. Advanced Topics in Science and Technology in China. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54575-1_23

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-54575-1_23

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-54573-7

  • Online ISBN: 978-3-662-54575-1

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics