Abstract
The UHVDC transmission system plays an extremely important role in the power grid. It is very urgent and necessary to carry out research on overvoltage of the UHVDC transmission system and appropriate control and protection measures. This chapter primarily takes a research on switching overvoltage of the UHVDC system. First, this chapter gives a discussion for classification and characteristics of switching overvoltage in the UHVDC systems. Then, by taking an actual example, this chapter gives a detailed introduction for calculation of typical kinds of switching overvoltage. Finally, this chapter gives an analysis and discussion for main switching overvoltage mechanisms, control and protection strategies.
This is a preview of subscription content, log in via an institution.
References
Xiangjiaba-Shanghai ±800 kV UHVDC transmission project AC filter transient rating. ABB Power Systems; 2007.
Xiangjiaba–Shanghai ±800 kV UHVDC transmission project AC filter arresters [R]. ABB Power Systems; 2007.
Dongju W, Deng X, Hao Z, Xilei C, Anwen X, Yang S. Research on converter valve overvoltage mechanism and calculation conditions of ±800 kV converter station (English). High Voltage Eng. 2012;38(12):3189–97.
Chen X, Zhou H, Yuan S, Wang D, Tian J, Huang Z, Lu Y. Overvoltage mechanism of converter valves for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2012;36(3):88–94.
Wang D, Deng X, Zhou H, Shen Y, Sun K. On the DC transient overvoltage in the converter stations of ±800 kV Xiluodu-Zhexi HVDC project. South Power Syst Technol. 2012;6(2):6–13.
Yuan S, Wang D, Chen X, Huang Z, Lu Y, Tian J, Chen W, Sun K, Zhou H. Study on neutral-bus overvoltage mechanism of ±500 kV DC power transmission project from Tianshengqiao to Guangdong. Power Syst Technol. 2011;35(5):216–22.
Chen X, Tian J, Wang D, Yuan S, Zhou H. Analysis on overvoltage in renovated control and protection system for HVDC power transmission project from Tianshengqiao to Guangzhou. Power Syst Technol. 2011;35(6):101–6.
Xiangjiaba–Shanghai ±800 kV UHVDC transmission project DC filter steady state rating. ABB Power Systems; 2008.
Xiangjiaba–Shanghai ±800 kV UHVDC transmission project DC filter transient rating; 2008.
Xiangjiaba–Shanghai ±800 kV UHVDC transmission project insulation coordination. ABB power systems; 2007.
Xiangjiaba–Shanghai ±800 kV UHVDC transmission project DC transient overvoltage; 2008.
Hingorani NG. Transient overvoltage on a bipolar HVDC overhead line caused by DC line Faults. IEEE Trans Power Appar Syst. 1970;PAS-89(4):592–610.
Melvold DJ, Odam PC, Vithayathil JJ. Transient overvoltage on an HVDC bipolar line during monopolar line faults. IEEE Trans Power Appar Syst. 1977;96(2):591–601.
Shi L. Study on the overvoltage on ±500 kV DC transmission line. Power Syst Technol. 1987;01:33–6.
Wu Y, Jiang W, Zhu Y, et al. Research on inner overvoltage in UHVDC transmission line caused by flashover to ground fault. Power Syst Technol. 2009;33(4):6–10.
Zhou P, Lv J, Dai M, et al. Slow front overvoltage and insulation coordination of ±800 kV UHVDC transmission line. High Volt Eng. 2009;35(7):1509–17.
Deng J, Xiao Y, Fan Y, et al. Calculation method of distributed parameters and application of DC projects in HVDC transmission lines based on two phase power. Resource. 2015;41(7):2451–6.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Zhejiang University Press, Hangzhou and Springer-Verlag GmbH Germany
About this chapter
Cite this chapter
Wang, D., Zhou, H., Li, J. (2017). Switching Overvoltage of UHVDC System. In: Zhou, H., et al. Ultra-high Voltage AC/DC Power Transmission. Advanced Topics in Science and Technology in China. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54575-1_16
Download citation
DOI: https://doi.org/10.1007/978-3-662-54575-1_16
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-54573-7
Online ISBN: 978-3-662-54575-1
eBook Packages: EnergyEnergy (R0)