Electromagnetic Environment of UHVAC System

  • Chapter
  • First Online:
  • 1126 Accesses

Part of the book series: Advanced Topics in Science and Technology in China ((ATSTC))

Abstract

The impacts of the UHVAC transmission project on the electromagnetic environment are mainly manifested in the land utilization, communication interference caused by the corona and audible noise as well as the impacts of the power frequency electromagnetic field on the ecology, etc. This chapter first compares the electromagnetic environment of the EHV/UHV power transmission lines, and then analyzes the electromagnetic environment of the UHVAC power transmission line. Next, the optimization of the phase sequence of the UHV double-circuit transmission line is discussed, and the safe distance of the UHV transmission line over the buildings is calculated and analyzed. Finally, the electromagnetic environment of the UHVAC substation is discussed preliminarily.

This is a preview of subscription content, log in via an institution.

Notes

  1. 1.

    “Average” refers to the mathematical expectation of probability in the strict sense, instead of the mean value.

References

  1. DL/T 1187-2012. Control levels for electromagnetic environment produced by 1000 kV overhead transmission line. 2012.

    Google Scholar 

  2. HJ/T 24-1998. Technical Regulations on environmental impact assessment of electromagnetic radiation produced by 500 kV ultrahigh voltage transmission and transfer power engineering. 1998.

    Google Scholar 

  3. Liu W, Zhao Q, Hu Z, Li X, Kang L, Zhao Y. Study on the corona loss estimate under the 1000 kV UHVAC transmission line. Electr Power Constr. 2011;32(10):27–9.

    Google Scholar 

  4. GB 15707-1995. Limits of radio interference from AC high voltage overhead power transmission lines. 1996.

    Google Scholar 

  5. GB 3096-2008. Environmental quality standard for noise. 2008.

    Google Scholar 

  6. Q/GDW 550-2010. Design and construction guide for reducing audible noise of transmission line. 2010.

    Google Scholar 

  7. Q/GDW 304-2009. Technical regulations for impact assessment of electromagnetic environment produced by 1000 kV transmission and transfer power engineering. 2009.

    Google Scholar 

  8. Q/GDW 178-2008. Provisional technical code for design of 1000 kV AC overhead transmission line. 2008.

    Google Scholar 

  9. Q/GDW 305-2009. Limits for electromagnetic environment generated by 1000 kV overhead power transmission lines. 2009.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xiao Zhang .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Zhejiang University Press, Hangzhou and Springer-Verlag GmbH Germany

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Zhang, X., Lu, H., Shen, Y., He, C. (2017). Electromagnetic Environment of UHVAC System. In: Zhou, H., et al. Ultra-high Voltage AC/DC Power Transmission. Advanced Topics in Science and Technology in China. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54575-1_13

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-54575-1_13

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-54573-7

  • Online ISBN: 978-3-662-54575-1

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics