Skip to main content

Analytical methods, biosensor technology

  • Chapter
Point-of-Care Testing

Abstract

This chapter explains the analytical principles incorporated into the POCT devices on the market. Furthermore, continuous monitoring methods are introduced that are already being used in patient care.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Aizawa M (1994) Immunosensors for clinical analysis. Adv Clin 31: 247–275

    Google Scholar 

  2. Berney HC, Alderman J, Lane WA, Collins JK (1998) Development of a capacitive immunosensor: a comparison of monoclonal and polyclonal capture antibodies as the primary layer. J Mol Recognit 11: 175–177

    Article  CAS  PubMed  Google Scholar 

  3. Buerk DG (1993) Biosensors. Theory and applications. Technomic Publishing, Lancaster, PA, pp 39–61

    Google Scholar 

  4. Clark LC (1956) US Patent a2,913,386

    Google Scholar 

  5. Gauglitz G, Brecht A, Kraus G, Mahm W (1993) Chemical and biochemical sensors based on interferometry at thin (multi-) layers. Sens Actuator B: Chemical 11: 1–3 and 21–27

    Article  CAS  Google Scholar 

  6. Gauglitz G (2010) Direct optical detection in bioanalysis: an update. Anal Bioanal Chem 398:2363–2372

    Article  CAS  PubMed  Google Scholar 

  7. Ghindilis AL, Atanasov P, Wilkins M, Wilkins E (1998) Immunosensors: electrochemical sensing and other engineering approaches. Biosens Bioelectron 13:113–131

    Article  CAS  PubMed  Google Scholar 

  8. Henrichs HR (2010) continual Glukosemessung (CGM) in der Gewebeflüssigkeit – Wissenschaftliche Bewertung of CGM and medizinische Beurteilung of the Nutzens for the Diabetestherapie (AGDT-DDG-GKV CGM-Positionspapier). Im Internet: www.diabetes-technologie.de/vortraege/vortraege-2010.htm

  9. Ittarat W, Chomean S, Sanchomphu C,Wangmaung N, Promptmas C, Ngrenngarmlert W (2013) Biosensor as a molecular malaria differential diagnosis. Clin Chim Acta 419: 47–51

    Article  CAS  Google Scholar 

  10. Liedberg B, Nylander C, Lundstrom I (1995) Biosensing with surface plasmon resonance – how it all started. Biosens Bioelectron 10: i–ix

    Article  CAS  PubMed  Google Scholar 

  11. López MA, Ortega F, Dominguez E, Katakis I (1998) Electrochemical immunosensor for the detection of atrazine. J Mol Recognit 11: 178–181

    Article  PubMed  Google Scholar 

  12. Luppa PB, Sokoll LJ, Chan DW (2001) Immunosensors – Principles and applications to clinical chemistry. Clin Chim Acta 314: 1–26

    Article  CAS  Google Scholar 

  13. Luppa PB, Müller C, Schlichtiger A, Schlebusch H (2011) Point-of-care testing (POCT): Current techniques and future perspectives. Tr Anal Chem 30:887–898

    Article  CAS  Google Scholar 

  14. Luppa PB, Bietenbeck A, Beaudoin C, Giannetti A (2016) Clinically relevant analytical techniques, organizational concepts for application and future perspectives of point-of-care testing. Biotechnol Adv. 2016 34: 139–160

    Article  PubMed  Google Scholar 

  15. Mathew R, Ravi Sankar A (2015) Design of a triangular platform piezoresistive affinity microcantilever sensor for biochemical sensing applications. J Phys D Appl Phys 48, 205402 (IOP Publishing)

    Article  CAS  Google Scholar 

  16. McNeil CJ, Athey D, Renneberg R (1997) Immunosensors for clinical diagnostics. EXS 81: 17–25

    Google Scholar 

  17. Oberhardt BJ, Dermott SC, Taylor M, Alkadi ZY, Abruzzini AF, Gresalfi NJ (1991) Dry reagent technology for rapid, convenient measurements of blood coagulation and fibrinolysis. Clin Chem 37: 520–526

    Google Scholar 

  18. Prakrankamanant P (2014) Quartz crystal microbalance biosensors: prospects for point of-care diagnostics. J. Med. Assoc. Thail. 97 (Suppl. 4)

    Google Scholar 

  19. Price CP, St John A, Hicks JM (2004) Point-of-care testing: what, why, when, and where? In: Price CP, St John A, Hicks JM (eds) Point-of care testing, 2nd edn. AACC Press, Washington, pp 3–12

    Google Scholar 

  20. Puiu M, Gurban A-M, Rotariu L, Brajnicov S, Viespe C, Bala C (2015) Enhanced sensitive love wave surface acoustic wave sensor designed for immunoassay formats. Sensors 15: 10511–10525

    Article  CAS  PubMed  Google Scholar 

  21. Ricciardi C, Canavese G, Castagna R, Ferrante I, Ricci A, Marasso SL, et al. (2010) Integration of microfluidic and cantilever technology for biosensing application in liquid environment. Biosens. Bioelectron 26: 1565–1570

    Article  CAS  PubMed  Google Scholar 

  22. Thalhammer S, Wixforth A (2013) Surface acoustic wave actuated Lab-on-Chip system for single cell analysis. Biosens Bioelectron 4: 1–7

    Google Scholar 

  23. Vashist SK (2013) Continuous Glucose Monitoring Systems: A Review. Diagnostics (Basel) 3:385–412

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Ziegler C, Göpel W (1998) Biosensor development. Curr Opinion Chem Biol 2: 585–591

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer-Verlag GmbH Germany, part of Springer Nature

About this chapter

Cite this chapter

Luppa, P.B., Proll, G., Imhoff, M., Koschinsky, T. (2018). Analytical methods, biosensor technology. In: Luppa, P.B., Junker, R. (eds) Point-of-Care Testing. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-54497-6_5

Download citation

Publish with us

Policies and ethics