Skip to main content

Comparison of Rigid Gradient-Based 2D/3D Registration Using Projection and Back-Projection Strategies

  • Conference paper

Part of the book series: Informatik aktuell ((INFORMAT))

Abstract

In this paper, a comparison of single-view gradient-based 2D/3D rigid registration methods is presented. To achieve dimensional correspondence between the images, projection and back-projection strategies have been proposed in the literature. Two similarity measures that are applicable for both strategies are involved in the comparison. Extensions of the similarity measure are proposed and compared to the original proposals. It is demonstrated that the projection strategy achieves a median accuracy up to 0.8 mm, which outperforms the back-projection strategy with a median accuracy of up to 1.1 mm. Our extension of the covariance-based similarity measure in combination with the back-projection strategy achieves the highest convergence range (up to 34.0 mm), while the the maximum achieved convergence range for the projection strategy is 31.3 mm.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Markelj P, Tomaževič D, Likar B, et al. A review of 3D/2D registration methods for image-guided interventions. Med Image Anal. 2012;16(3):642–61.

    Article  Google Scholar 

  2. Gendrin C, Markelj P, Pawiro SA, et al. Validation for 2D/3D registration II: the comparison of intensity- and gradient-based merit functions using a new gold standard data set. Med Phys. 2011;38(3):1491–502.

    Article  Google Scholar 

  3. Wein W, Roeper B, Navab N. 2D/3D registration based on volume gradients. Proc SPIE. 2005;5747:144–50.

    Article  Google Scholar 

  4. Tomaževič D, Likar B, Slivnik T, et al. 3-D/2-D registration of CT and MR to X-ray images. IEEE Trans Med Imaging. 2003;22(11):1407–16.

    Article  Google Scholar 

  5. Markelj P, Tomaževič D, Pernuš F, et al. Robust gradient-based 3-D/2-D registration of CT and MR to X-ray images. IEEE Trans Med Imaging. 2008;27(12):1704–14.

    Article  Google Scholar 

  6. Špiclin Ž, Likar B, Pernuš F., Fast and Robust 3D to 2D image registration by backprojection of gradient covariances. Biomed Image Regist. 2014;8545:124–33.

    Google Scholar 

  7. Wang J, Borsdorf A, Heigl B, et al. Gradient-based differential approach for 3-D motion compensation in interventional 2-D/3-D image fusion. Proc Int Conf 3D Vis. 2014;1:293–300.

    Google Scholar 

  8. van de Kraats EB, Penney GP, Tomaževič D, et al. Standardized evaluation methodology for 2-D-3-D registration. IEEE Trans Med Imaging. 2005;24(9):1177–89.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2016 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Schaffert, R., Wang, J., Borsdorf, A., Hornegger, J., Maier, A. (2016). Comparison of Rigid Gradient-Based 2D/3D Registration Using Projection and Back-Projection Strategies. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2016. Informatik aktuell. Springer Vieweg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49465-3_26

Download citation

Publish with us

Policies and ethics