Abstract
For solving the problem of network-side voltage interruption, this paper proposes a method that can detect fastly. A method to protect the system in order to avoid the impact of the alternating current after the voltage interruption is given in this paper. It also presents some data of simulations and experiments to verify the feasibility of this scheme.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
He S, Xuan Z (2010) China high speed railway: lead global. Transp Guangdong 02:4–9 (in Chinese)
Feng L, Liu H, Wang S, Gao X (2005) Bow net separated monitoring system in electric locomotive. Electric Drive Locomotive 02:57–58 + 60 (in Chinese)
Ju C (2012) Analyze the harm and prevention measures of bow net separation in electric railway. Technol Gansu 01:70–71 + 79 (in Chinese)
Zhang X (2003) The research on the PWM rectifier and its control strategy. Hefei University of Technology (in Chinese)
Jiang L (2013) The control strategy of network-side converter in dual-power electric multiple units. Beijing Jiaotong Univ 11:291–292
Ofeng L, Hui O, Yong K et al (2009) The research of single-phase PWM rectifier based on direct current control technology. In: Proceedings of 2nd international conference on power electronics and intelligent transportation system (PEITS) IEEE, vol 3, pp 276–279
Zhang W, Zhou N, Li R, Mei G, Song D (2011) Pantograph and catenary system with double pantographs for high-speed trains at 350 km/h or higher. J Mod Transp 01:7–11
Ambrósio J, Pombo J, Pereira M (2013) Optimization of high-speed railway pantographs for improving pantograph-catenary contact. Theor Appl Mech Lett 01:51–57
Acknowledgments
This work was supported by National Science and Technology Support Project under Grant No. 2015BAG13B01, 2013BAG24B01 and 2013BAG21QB00, and in part by Beijing Education Committee, Major Achievement Transformation Project for the Central Universities ZDZH20141000401. It is also supported by the Fundamental Research Funds for the Central Universities 2013YJS088 and 2014JBM114.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Zhang, X., Zhang, G., Jiang, L., Liu, Z. (2016). The Research on Solution of Voltage Interruption of Network-Side Converter in Dual-Power EMU. In: Jia, L., Liu, Z., Qin, Y., Ding, R., Diao, L. (eds) Proceedings of the 2015 International Conference on Electrical and Information Technologies for Rail Transportation. Lecture Notes in Electrical Engineering, vol 377. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49367-0_13
Download citation
DOI: https://doi.org/10.1007/978-3-662-49367-0_13
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-662-49365-6
Online ISBN: 978-3-662-49367-0
eBook Packages: EnergyEnergy (R0)