Sensing by Optic Biosignals

  • Eugenijus KaniusasEmail author
Chapter
Part of the Biological and Medical Physics, Biomedical Engineering book series (BIOMEDICAL)

Abstract

Open image in new window

After the interface between physiologic mechanisms and the resultant biosignals has been examined (Volume I), the subsequent interface between optic biosignals and the associated sensing technology is discussed here. In the genesis of optic biosignals—induced biosignals—an artificial light is coupled into biological tissue. The resulting transmitted light intensity is strongly governed by the light absorption and scattering in tissue. The light absorption, for instance, is modulated by blood oxygenation and local pulsatile blood volume. Consequently, the transmitted light intensity reflects multiple physiologic parameters—which are vital for the assessment of cardiorespiratory pathologies and the state of health—and comprises the optic biosignal. The genesis of optic biosignals is considered from a strategic point of view. In particular, the introduced common frame of hybrid biosignals comprises both the biosignal formation path from the biosignal source at the physiological level to biosignal propagation in the body, and the biosignal sensing path from the biosignal transmission in the sensor applied on the body up to its conversion to an electric signal. Namely, the optical sensor is comprised of a light source on the skin to generate the incident light and couple it into tissue, and a distant light sink to detect the resulting transmitted light. The transilluminated region can be approximated as an arrangement of tissue layers and blood vessels. If an arterial vessel is considered with a blood pressure pulse propagating along the vessel, then there is a local pulsatile change in the arterial radius. Provided that blood in vessels absorbs the light to a larger extent compared to the tissues surrounding these vessels, it is clear that the transmitted light intensity temporarily decreases for increasing arterial radius in the transilluminated region. Thus, the propagating light is modulated by diverse physiological phenomena. A certain portion of light leaves the body and is detected by the light sink applied on the skin. The sink converts the transmitted light intensity into the electric signal. It is highly instructive from an engineering and clinical point of view how light interacts with biological tissues. Discussed phenomena teach a lot about the physics of light (as engineering sciences), and, on the other hand, biology and physiology (as live sciences). Basic and application-related issues are covered in depth. In fact, these issues should remain strong because these stand the test of time and mine knowledge of great value. Obviously, the highly interdisciplinary nature of optic biosignals and biomedical sensors is a challenge. However, it is a rewarding challenge after it has been coped with in a strategic way, as offered here. The chapter is intended to have the presence to answer intriguing “Aha!” questions.

References

  1. H.H. Asada, P. Shaltis, A. Reisner, R. Sokwoo, R.C. Hutchinson, Mobile monitoring with wearable photoplethysmographic biosensors. IEEE Eng. Med. Biol. Mag. 22(3), 28–40 (2003)CrossRefGoogle Scholar
  2. A.A. Awad, M.A. Ghobashy, W. Ouda, R.G. Stout, D.G. Silverman, K.H. Shelley, Different responses of ear and finger pulse oximeter wave form to cold pressor test. Anesth. Analg. 92(6), 1483–1486 (2001)CrossRefGoogle Scholar
  3. A.N. Bashkatov, E.A. Genina, V.I. Kochubey, V.V. Tuchin, Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2,000 nm. J. Phys. D Appl. Phys. 38, 2543–2555 (2005)CrossRefGoogle Scholar
  4. D.E. Bebout, P.D. Mannheimer, C.C. Wun, Site-dependent differences in the time to detect changes in saturation during low perfusion. Crit. Care Med. 29(12), 115 (2001)Google Scholar
  5. D.A. Benaron, I.H. Parachikov, W.F. Cheong, S. Friedland, B.E. Rubinsky, D.M. Otten, F.W. Liu, C.J. Levinson, A.L. Murphy, J.W. Price, Y. Talmi, J.P. Weersing, J.L. Duckworth, U.B. Hörchner, E.L. Kermit, Design of a visible-light spectroscopy clinical tissue oximeter. J. Biomed. Opt. 10(4), 44005-1–44005-9 (2005)Google Scholar
  6. L. Bernardi, A. Radaelli, P.L. Solda, A.J. Coats, M. Reeder, A. Calciati, C.S. Garrard, P. Sleight, Autonomic control of skin microvessels: assessment by power spectrum of photoplethysmographic waves. Clin. Sci. 90(5), 345–355 (1996)Google Scholar
  7. L. Bernardi, M. Rossi, S. Leuzzi, E. Mevio, G. Fornasari, A. Calciati, C. Orlandi, P. Fratino, Reduction of 0.1 Hz microcirculatory fluctuations as evidence of sympathetic dysfunction in insulin-dependent diabetes. Cardiovasc. Res. 34(1), 185–191 (1997)CrossRefGoogle Scholar
  8. Biomedical Optics Research Laboratory, University College London, Department of Medical Physics and Bioengineering, www.ucl.ac.uk (2010)
  9. D. Chamier, Unpublished ball pen drawing (Institute of Art and Design, Vienna University of Technology, Vienna, 2014)Google Scholar
  10. W.F. Cheong, S.A. Prahl, A.J. Welch, A review of the optical properties of biological tissues. IEEE J. Quantum Electron. 26(12), 2166–2185 (1990)CrossRefGoogle Scholar
  11. C. Clark, R. Vinegar, J.D. Hardy, Goniometric spectrometer for the measurement of diffuse reflectance and transmittance of skin in the infrared spectral region. J. Opt. Soc. Am. 43(11), 993–998 (1953)CrossRefGoogle Scholar
  12. G. Comtois, Y. Mendelson, P. Ramuka, A comparative evaluation of adaptive noise cancellation algorithms for minimizing motion artifacts in a forehead-mounted wearable pulse oximeter, in Proceedings of the 29th Annual EMBS International Conference, pp. 1528–1531 (2007)Google Scholar
  13. M. Cope, The application of near infrared spectroscopy to non invasive monitoring of cerebral oxygenation in the newborn infant. Thesis at the University College London (1991)Google Scholar
  14. R.J. Davies-Colley, W.N. Vant, D.G. Smith, Colour and Clarity of Natural Waters (The Blackburn Press, Caldwell, 2003)Google Scholar
  15. German Institute for Standardization (in German: Deutsches Institut für Normung), norm DIN 33403-3 on climate at the workplace and its environments (2011)Google Scholar
  16. A. Duncan, J.H. Meek, M. Clemence, C.E. Elwell, L. Tyszczuk, M. Cope, D.T. Delpy, Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. Phys. Med. Biol. 40(2), 295–304 (1995)CrossRefGoogle Scholar
  17. S. Duun, R.G. Haahr, K. Birkelund, P. Raahauge, P. Petersen, H. Dam, L. Noergaard, E.V. Thomsen: a novel ring shaped photodiode for reflectance pulse oximetry in wireless applications. IEEE Sens. 15, 596–599 (2007)Google Scholar
  18. C. Elwell, J. Hebden, Near-infrared spectroscopy. Biomed. Opt. Res. Lab. http://www.medphys.ucl.ac.uk/research/borl/research/NIR_topics/nirs.htm (1999)
  19. Y.S. Fawzi, A.M. Youssef, M.H. El-Batanony, Y.M. Kadah, Determination of the optical properties of a two-layer tissue model by detecting photons migrating at progressively increasing depths. Appl. Opt. 42(31), 6398–6411 (2003)CrossRefGoogle Scholar
  20. M.A. Franceschini, E. Gratton, D. Hueber, S. Fantini, Near-infrared absorption and scattering spectra of tissues in vivo. Proc. Soc. Opt. Eng. 3597, 526–531 (1999a)Google Scholar
  21. M.A. Franceschini, E. Gratton, S. Fantini, Noninvasive optical method of measuring tissue and arterial saturation: An application to absolute pulse oximetry of the brain. Opt. Lett. 24(12), 829–831 (1999b)CrossRefGoogle Scholar
  22. M.A. Franceschini, D.A. Boas, A. Zourabian, S.G. Diamond, S. Nadgir, D.W. Lin, J.B. Moore, S. Fantini, Near-infrared spiroximetry: noninvasive measurements of venous saturation in piglets and human subjects. J. Appl. Physiol. 92(1), 372–384 (2002)Google Scholar
  23. C. Furse, D.A. Christensen, C.H. Durney, Basic Introduction to Bioelectromagnetics (CRC Press Publisher, Boca Raton, 2009)Google Scholar
  24. E.A. Genina, A.N. Bashkatov, V.V. Tuchin, Optical clearing of cranial bone. Adv. Opt. Technol. ID 267867, 1–8 (2008)CrossRefGoogle Scholar
  25. D.C. Giancoli, Physics (In German: Physik) (Pearson Studium Publisher, Munich, 2006)Google Scholar
  26. J.M. Goldman, M.T. Petterson, R.J. Kopotic, S.J. Barker, Masimo signal extraction pulse oximetry. J. Clin. Monit. Comput. 16(7), 475–483 (2000)CrossRefGoogle Scholar
  27. J.D. Hardy, H.T. Hammel, D. Murgatroyd, Spectral transmittance and reflectance of excised human skin. J. Appl. Physiol. 9(2), 257–264 (1956)Google Scholar
  28. E. Hill, M.D. Stoneham, Practical applications of pulse oximetry. World Anaesth. Online 11(4), 1–2 (2000)Google Scholar
  29. E.M.C. Hillman, Experimental and theoretical investigations of near infrared tomographic imaging methods and clinical applications. Thesis at the University of London (2002)Google Scholar
  30. W. Hoppe, W. Lohmann, H. Markl, H. Ziegler, Biophysik (Springer, Berlin, 1982)Google Scholar
  31. International Commission on Non-Ionizing Radiation Protection, ICNIRP guidelines on limits of exposure to broad-band incoherent optical radiation (0.38–3 µm). Health Phys. 73(3), 539–554 (1997)Google Scholar
  32. International Commission on Non-Ionizing Radiation Protection, ICNIRP statement on far infrared radiation exposure. Health Phys. 91(6), 630–645 (2006)CrossRefGoogle Scholar
  33. S.L. Jacques, Skin optics. Online Oregon Medical Laser Center http://omlc.ogi.edu/news/jan98/skinoptics.html (1998)
  34. S.L. Jacques, S.A. Prahl, Introduction to biomedical optics. Oregon Graduate Institute http://omlc.bme.ogi.edu/classroom/ece532/index.html (2002)
  35. S.L. Jacques, Optical Properties of Tissue. Tutorial Lecture at the Graduate Summer School Bio-Photonics in Sweden (2003)Google Scholar
  36. A. Jubran, Pulse oximetry. Crit. Care 3(2), R11–R17 (1999)CrossRefGoogle Scholar
  37. V. Kamat, Pulse oximetry. Indian J. Anaesth. 46(4), 261–268 (2002)Google Scholar
  38. E. Kaniusas, Multiparametric Physiological Sensors. Habilitation theses at the Vienna University of Technology (2006)Google Scholar
  39. E. Kaniusas, H. Pfützner, L. Mehnen, Optical tissue absorption sensor on the thorax: Possibilities and restrictions. Int. J. Appl. Electromagn. Mech. 25(1–4), 649–655 (2007)Google Scholar
  40. E. Kaniusas, G. Varoneckas, B. Mahr, J.C. Szeles, Optic visualisation of auricular nerves and blood vessels: optimisation and validation. IEEE Trans. Instrum. Meas. 60(10), 3253–3258 (2011)CrossRefGoogle Scholar
  41. J.M. Kim, K. Arakawa, K.T. Benson, D.K. Fox, Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography. Anesth. Analg. 65(12), 1333–1339 (1986)Google Scholar
  42. V. König, R. Huch, A. Huch, Reflectance pulse oximetry—principles and obstetric application in the Zurich system. J. Clin. Monit. Comput. 14, 403–412 (1998)CrossRefGoogle Scholar
  43. H. Krieger, Basics of Radiation Physics and Radiation Protection (In German: Grundlagen der Strahlungsphysik und des Strahlenschutzes) (Teubner Publisher, Leipzig, 2004)Google Scholar
  44. R. Krishnan, B. Natarajan, S. Warren, Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data. IEEE Trans. Biomed. Eng. 57(8), 1867–1876 (2010)CrossRefGoogle Scholar
  45. G. Kumar, J.M. Schmitt, Optimal probe geometry for near infrared spectroscopy of biological tissue. Appl. Opt. 36(10), 2286–2293 (1997)CrossRefGoogle Scholar
  46. P.A. Kyriacou, S. Powell, R.M. Langford, D.P. Jones, Esophageal pulse oximetry utilizing reflectance photoplethysmography. IEEE Trans. Biomed. Eng. 49(11), 1360–1368 (2002)CrossRefGoogle Scholar
  47. J.C. Lai, Y.Y. Zhang, Z.H. Li, H.J. Jiang, A.Z. He, Complex refractive index measurement of biological tissues by attenuated total reflection ellipsometry. Appl. Opt. 49(16), 3235–3238 (2010)CrossRefGoogle Scholar
  48. J. Ling, S. Takatani, G.P. Noon, Y. Nose, In-vivo studies of reflectance pulse oximeter sensor. Proc. Int. Soc. Opt. Photonics (SPIE) 1887, 256–262 (1993)Google Scholar
  49. P.D. Mannheimer, J.R. Casciani, M.E. Fein, S.L. Nierlich, Wavelength selection for low-saturation pulse oximetry. IEEE Trans. Biomed. Eng. 44(3), 148–158 (1997)CrossRefGoogle Scholar
  50. B. Manzke, J. Schwider, N. Lutter, K. Engelhardt, W. Stork, Multiwavelength pulse oximetry in the measurement of hemoglobin fractions. Proc. Soc. Opt. Eng. 2676, 332–340 (1996)Google Scholar
  51. S.A. Mascaro, H.H. Asada, Photoplethysmograph fingernail sensors for measuring finger forces without haptic obstruction. IEEE Trans. Robot. Autom. 17(5), 698–708 (2001)CrossRefGoogle Scholar
  52. I.V. Meglinski, S.J. Matcher, Quantitative assessment of skin layers absorption and skin reflectance spectra simulation in the visible and near-infrared spectral regions. Physiol. Meas. 23(4), 741–753 (2002)CrossRefGoogle Scholar
  53. Y. Mendelson, B.D. Ochs, Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography. IEEE Trans. Biomed. Eng. 35(10), 798–805 (1988)CrossRefGoogle Scholar
  54. P.M. Middleton, C.H.H. Tang, G.S.H. Chan, S. Bishop, A.V. Savkin, N.H. Lovell, Peripheral photoplethysmography variability analysis of sepsis patients. Med. Biol. Eng. Compu. 49(3), 337–347 (2011)CrossRefGoogle Scholar
  55. J.R. Mourant, J.P. Freyer, A.H. Hielscher, A.A. Eick, D. Shen, T.M. Johnson, Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnosis. Appl. Opt. 37(16), 3586–3593 (1998)CrossRefGoogle Scholar
  56. Specific extinction spectra of tissue chromophores, Online Biomedical Optics Research Laboratory http://www.medphys.ucl.ac.uk/research/borl/research/NIR_topics/spectra/spectra.htm (2003)
  57. H. Pfützner, Applied Biophysics (In German: Angewandte Biophysik) (Springer, Berlin, 2003)Google Scholar
  58. S. Prahl, Optical absorption of hemoglobin. Online Oregon Medical Laser Center http://omlc.bme.ogi.edu/spectra/hemoglobin/index.html (1999)
  59. S. Reichelt, J. Fiala, A. Werber, K. Forster, C. Heilmann, R. Klemm, H. Zappe, Development of an implantable pulse oximeter. IEEE Trans. Biomed. Eng. 55(2), 581–588 (2008)CrossRefGoogle Scholar
  60. G.M. Roger, Clinical Electrocardiography and Arrhythmias. Lecture notes from the Massachusetts Institute of Technology (2004)Google Scholar
  61. D.K. Sardar, L.B. Levy, Optical properties of whole blood. Lasers Med. Sci. 13(2), 106–111 (1998)CrossRefGoogle Scholar
  62. J.M. Schmitt, Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry. IEEE Trans. Biomed. Eng. 38(12), 1194–1203 (1991)CrossRefGoogle Scholar
  63. D.J. Segelstein, The complex refractive index of water. Theses at the University of Missouri-Kansas City (1981)Google Scholar
  64. M. Shafique, P.A. Kyriacou, S.K. Pal, Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor. Med. Biol. Eng. Compu. 50, 575–583 (2012)CrossRefGoogle Scholar
  65. C.R. Simpson, M. Kohl, M. Essenpreis, M. Cope, Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the monte carlo inversion technique. Phys. Med. Biol. 43, 2465–2478 (1998a)CrossRefGoogle Scholar
  66. C.R. Simpson, J. Laufer, M. Kohl, M. Essenpreis, M. Cope, Measurement of skin optical properties. Online Biomedical Optics Research Laboratory http://www.medphys.ucl.ac.uk/research/borl/research/NIR_topics/skin/skinoptprop.htm (1998b)
  67. J. Sola, O. Chetelat, J. Krauss, On the reliability of pulse oximetry at the sternum, in Proceedings of the 29th Annual EMBS International Conference, pp. 1537 (2007a)Google Scholar
  68. J. Sola, O. Chetelat, Combination of multiple light paths in pulse oximetry: the finger ring example. in Proceedings of the 29th Annual EMBS International Conference, pp. 6697–6698 (2007b)Google Scholar
  69. J. Sola, S. Castoldi, O. Chetelat, M. Correvon, S. Dasen, S. Droz, N. Jacob, R. Kormann, V. Neumann, A. Perrenoud, P. Pilloud, C. Verjus, G. Viardot, SpO2 sensor embedded in a finger ring: design and implementation, in Proceedings of the 28th Annual EMBS International Conference, pp. 4295–4298 (2006)Google Scholar
  70. R. Splinter, B.A. Hooper, An Introduction to Biomedical Optics (Publisher Taylor and Francis, Oxford, 2007)Google Scholar
  71. S. Takatani, J. Ling, Optical oximetry sensors for whole blood and tissue. IEEE Eng. Med. Biol. Mag. 13(3), 347–357 (1994)CrossRefGoogle Scholar
  72. X.F. Teng, Y.T. Zhang, The effect of contacting force on photoplethysmographic signals. Physiol. Meas. 25(5), 1323–1335 (2004)CrossRefGoogle Scholar
  73. T. Torfs, V. Leonov, R.J.M. Vullers, Pulse oximeter fully powered by human body heat. Sens. Transducers J. 80(6), 1230–1238 (2007)Google Scholar
  74. V.V. Tuchin, Optical clearing of tissues and blood using the immersion method. J. Phys. D Appl. Phys. 38(15), 2497–2518 (2005)CrossRefGoogle Scholar
  75. N. Ugryumova, S.J. Matcher, D.P. Attenburrow, Measurement of bone mineral density via light scattering. Phys. Med. Biol. 49, 469–483 (2004)CrossRefGoogle Scholar
  76. B. Venema, N. Blanik, V. Blazek, H. Gehring, A. Opp, S. Leonhardt, Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: results of a human hypoxia study. IEEE Trans. Biomed. Eng. 59(7), 2003–2010 (2012)CrossRefGoogle Scholar
  77. C.Y. Wang, M.L. Chuang, S.J. Liang, J. Tsai, C.C. Chuang, Y.S. Hsieh, C.W. Lu, P.L. Lee, C.W. Sun, Diffuse optical multipatch technique for tissue oxygenation monitoring: clinical study in intensive care unit. IEEE Trans. Biomed. Eng. 59(1), 87–94 (2012)CrossRefGoogle Scholar
  78. Scattering by pure water. WET Labs http://www.wetlabs.com/iopdescript/purescatter2.htm (2005)
  79. B. Winey, Y. Yan, Oximetry considerations in the small source detector separation limit, in Proceedings of the 28th Annual EMBS International Conference, pp. 1941–1943 (2006)Google Scholar
  80. R.A. Winter, Arterial blood flow simulator. U.S. Patent Nr. 6400973 (2002)Google Scholar
  81. M.W. Wukitsch, M.T. Petterson, D.R. Tobler, J.A. Pologe, Pulse oximetry: analysis of theory, technology, and practice. J. Clin. Monit. 4(4), 290–301 (1988)CrossRefGoogle Scholar
  82. Y. Xu, N. Iftimia, H. Jiang, L.L. Key, M.B. Bolster, Imaging of in vitro and in vivo bones and joints with continuous-wave diffuse optical tomography. Opt. Express 8(7), 447–451 (2001)CrossRefGoogle Scholar
  83. J.I. Youn, S.A. Telenkov, E. Kim, N.C. Bhavaraju, B.J.F. Wong, J.W. Valvano, T.E. Milner, Optical and thermal properties of nasal septal cartilage. Lasers Surg. Med. 27(2), 119–128 (2000)CrossRefGoogle Scholar
  84. G. Zonios, U. Shankar, V.K. Iyer, Pulse oximetry theory and calibration for low saturations. IEEE Trans. Biomed. Eng. 51(5), 818–822 (2004)CrossRefGoogle Scholar
  85. A. Zourabian, A. Siegel, B. Chance, N. Ramanujan, M. Rode, D.A. Boas, Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry. J. Biomed. Opt. 5(4), 391–405 (2000)CrossRefGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2015

Authors and Affiliations

  1. 1.Head of research group ‘Biomedical Sensors’, Vienna University of TechnologyInstitute of Electrodynamics, Microwave and Circuit EngineeringViennaAustria

Personalised recommendations