Skip to main content

Procedure for Small Bowel Video Capsule Endoscopy

  • Chapter
  • First Online:

Abstract

The standard equipment necessary to perform a small bowel video capsule endoscopy (SBCE) procedure is summarized in Table 4.1. A video capsule designed for small bowel evaluation is required. Measuring 26 mm × 11 mm, current models operate at either a fixed frame rate of 4 frames per second (Fig. 4.1) or an adaptive frame rate of 2–6 frames per second. Each capsule is sealed in a small box and marked with an identifiable number and expiration date. The capsule is activated upon opening the box and has a minimum battery life of 12 h. Specific technological detail was discussed further in Chap. 3.

The work was first published in 2006 by Springer Medizin Verlag Heidelberg with the following title: Atlas of Video Capsule Endoscopy.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD   199.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Wu L, Cao Y, Liao C, et al. Systematic review and meta-analysis of randomized controlled trials of simethicone for gastrointestinal endoscopic visibility. Scand J Gastroenterol. 2011;46:227–35.

    Article  PubMed  Google Scholar 

  2. Albert J, Gobel CM, Lebke J, et al. Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled trial. Gastrointest Endosc. 2004;60:534–8.

    Article  Google Scholar 

  3. Storch I, Barkin S. Contraindications to capsule endoscopy: do any still exist? Gastrointest Endosc Clin N Am. 2006;16:329–36.

    Article  PubMed  Google Scholar 

  4. Mishkin DS. Day of the procedure. In: de Franchis R, Lewis BS, Mishkin DS, editors. Capsule endoscopy simplified. Thorofare: SLACK Inc.; 2010. p. 15–24.

    Google Scholar 

  5. Given Imaging Ltd. PillCam SB: Information for health professionals. http://www.givenimaging.com/en-us/Innovative-Solutions/Capsule-Endoscopy/Pillcam-SB/HCP-Resources/Pages/What-Your-Patient-Can-Expect.aspx. Accessed 6 Nov 2013.

  6. Spada C, Riccioni ME, Familiari P, et al. Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy. Dig Liver Dis. 2010;42:365–70.

    Article  CAS  PubMed  Google Scholar 

  7. Wi JH, Moon JS, Choi MG, et al. Bowel preparation for capsule endoscopy: a prospective randomized multicenter study. Gut Liver. 2009;3:180–5.

    Article  PubMed Central  PubMed  Google Scholar 

  8. Wei W, Ge ZZ, Lu H, et al. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging. Am J Gastroenterol. 2008;103:77–82.

    Article  PubMed  Google Scholar 

  9. Rokkas T, Papaxoinis K, Triantafyllou K, et al. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy? A meta-analysis. Am J Gastroenterol. 2009;104:219–27.

    Article  CAS  PubMed  Google Scholar 

  10. Belsey J, Crosta C, Epstein O, et al. Meta-analysis: efficacy of small bowel preparation for small bowel video capsule endoscopy. Curr Med Res Opin. 2012;28:1883–90.

    Article  PubMed  Google Scholar 

  11. Chen HB, Huang Y, Chen SY, et al. Small bowel preparations for capsule endoscopy with mannitol and simethicone: a prospective, randomized clinical trial. J Clin Gastroenterol. 2011;45:337–41.

    Article  CAS  PubMed  Google Scholar 

  12. Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009;69:74–80.

    Article  PubMed  Google Scholar 

  13. Lee MM, Jacques A, Lam E, et al. Factors associated with incomplete small bowel capsule endoscopy studies. World J Gastroenterol. 2010;16:5329–33.

    Article  PubMed Central  PubMed  Google Scholar 

  14. Fireman Z, Kopelman Y, Friedman S, et al. Age and indication for referral to capsule endoscopy significantly affect small bowel transit times: the Given database. Dig Dis Sci. 2007;52:2884–7.

    Article  PubMed  Google Scholar 

  15. Alim S, Matin S, Mann M, et al. Factors affecting capsule endoscopy transit time (abstract). Gastroenterology. 2007;132 Suppl 2:310.

    Google Scholar 

  16. Ben-Soussan E, Savoye G, Antonietti M, et al. Factors that affect gastric passage of video capsule. Gastrointest Endosc. 2005;62:785–90.

    Article  PubMed  Google Scholar 

  17. Lai LH, Wong GL, Lau JY, et al. Initial experience of real-time capsule endoscopy in monitoring progress of the videocapsule through the upper GI tract. Gastrointest Endosc. 2007;66:1211–4.

    Article  PubMed  Google Scholar 

  18. Spada C, Riccioni ME, Costamagna G. Rapid Access Real-Time device and Rapid Access software: new tools in the armamentarium of capsule endoscopy. Expert Rev Med Devices. 2007;4:431–5.

    Article  PubMed  Google Scholar 

  19. Delvaux M, Gay G. Real-time viewing of capsule endoscopy recordings: principle and clinical potential. Tech Gastrointest Endosc. 2006;8:160–3.

    Article  Google Scholar 

  20. Despott E, O’Rourke A, Anikin V, et al. Tracheal aspiration of capsule endoscopes: detection, management and susceptibility. Dig Dis Sci. 2012;57:1973–4.

    Article  PubMed  Google Scholar 

  21. Holden JP, Dureja P, Pfau PR, et al. Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device. Gastrointest Endosc. 2007;65:842–7.

    Article  PubMed  Google Scholar 

  22. Skogestad E, Tholfsen JK. Capsule endoscopy: in difficult cases the capsule can be ingested through an overtube. Endoscopy. 2004;36:1038.

    Article  CAS  PubMed  Google Scholar 

  23. Postgate A, Tekkis P, Patterson N, et al. Are bowel purgatives and prokinetics useful for small-bowel capsule endoscopy? A prospective randomized controlled study. Gastrointest Endosc. 2009;69:1120–8.

    Article  PubMed  Google Scholar 

  24. Zhang JS, Ye LP, Zhang JL, et al. Intramuscular injection of metoclopramide decreases the gastric transit time and does not increase the complete examination rate of capsule endoscopy: a prospective randomized controlled trial. Hepatogastroenterology. 2011;58:1618–21.

    Article  PubMed  Google Scholar 

  25. Iwamoto J, Mizokami Y, Shimokobe K, et al. The effect of metoclopramide in capsule endoscopy. Hepatogastroenterology. 2010;57:1356–9.

    PubMed  Google Scholar 

  26. Selby W. Complete small bowel transit in patients undergoing capsule endoscopy: determining factors and improvement with metoclopramide. Gastrointest Endosc. 2005;61:80–5.

    Article  PubMed  Google Scholar 

  27. Fireman Z, Paz D, Kopelman Y, et al. Capsule endoscopy: improving transit time and image view. World J Gastroenterol. 2005;11:5863–6.

    PubMed  Google Scholar 

  28. Leung WK, Chan FK, Fung SS, et al. Effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy. World J Gastroenterol. 2005;11:4865–8.

    CAS  PubMed  Google Scholar 

  29. Keuchel M, Voderholzer WA, Schenk G, et al. Domperidone shortens gastric transit time of videocapsule endoscopy (VCE). Gastrointest Endosc. 2003;57:AB163.

    Google Scholar 

  30. Ito T, Ohata K, Ono A, et al. Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy. World J Gastroenterol. 2012;18:1789–92.

    Article  CAS  PubMed Central  PubMed  Google Scholar 

Internet

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Carolyn Davison .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Davison, C., de Franchis, R., Iannuzzi, F. (2014). Procedure for Small Bowel Video Capsule Endoscopy. In: Keuchel, M., Hagenmüller, F., Tajiri, H. (eds) Video Capsule Endoscopy. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-44062-9_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-662-44062-9_4

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-662-44061-2

  • Online ISBN: 978-3-662-44062-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics