Advertisement

Abstract

As an extension of the surface application of radium, treatment by “radium at a distance” was introduced more than fifty years ago. By this method a larger percentage depth dose could be produced and more deeply seated lesions became accessible for irradiation by the hard gamma rays from radium.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Baarli, J.: The properties of a new caesium-137 plesiotherapy unit shielded with tungsten alloy and uranium. Progr. Nuclear Energy 2, 229–240 (1959).Google Scholar
  2. Brucer, M.: Teletherapy devices with radioactive isotopes. Internat. Conf. peaceful uses atomic energy 10, 68–74 (1956).Google Scholar
  3. Burns, J. E., J. B. Perry, N. H. Pierce, E. E. Trotman and C. W. Wilson: A kilocurie caesium-137 beam unit at Westminster Hospital: Physical aspects. Brit. J. Eadiol. 32, 215–223 (1959).Google Scholar
  4. Clarkson, J. K., H. J. Leech, A. G. C. Taylor and S. W. A. Mason: A moving-beam caesium-137 telecurie unit. Brit. J. Eadiol. 32, 798–804 (1959).Google Scholar
  5. Cole, A., W. K. Sinclair, G. H. Fletcher and G. C. Johnson: Physical studies on a shorttreatment-distance cesium-137 teletherapy unit. Eadiology 74, 731–742 (1960).Google Scholar
  6. Dahl, O., F. Jacobsson and E. Walstam: Telegamma therapy of laryngeal carcinoma. Acta Uni. int. Cancer. 20, 1735–1737 (1964).Google Scholar
  7. Dahl, O., B. Lindell and E. Walstam: Der neue Telegammaapparat des Eadiumhemmet. Strahlenforschung und Strahlenbehandlung. Sonderbd. Strahlentherapie 35, 253–265 (1956).Google Scholar
  8. Dahl, O., B. Lindell and E. Walstam: Editorial, Brit. J. Eadiol. 28, 1 (1955).Google Scholar
  9. Edsmyr, F., and E. Walstam: A method for irradiation of parasternal lymph-node metastases. Acta radiol. (Stockh.) 51, 308–320 (1959).CrossRefGoogle Scholar
  10. Griffith, H.D.: A test of some methods for calculating dosage in radium therapy. Acta radiol. (Stockh.) 14, 608–614 (1933).CrossRefGoogle Scholar
  11. Haybittle, J.L., and J. Dallison: A caesium-137 gamma ray therapy unit. Acta radiol. (Stockh.) 50, 321–332 (1958).CrossRefGoogle Scholar
  12. Hine, G. J.: Secondary electron emission and effective atomic numbers. Nucleonics 10, 9–15 (1952).Google Scholar
  13. Hornykiewytsch, T.: Hinweise zur Telekobaltbehandlung. Strahlentherapie 115, 233–256 (1961).PubMedGoogle Scholar
  14. Hultberg, S., O. Dahl, E. Thoraeus, K. J. Vikterlöf and E. Walstam: Kilocurie cobalt-60 therapy at the radiumhemmet. Acta radiol. (Stockh.) Suppl. 179 (1959).Google Scholar
  15. Hultberg, S., and B. Martenson: Irradiation treatment of malignant tumours of the oral cavity. Transactions IX. Intern. Congr. Eadiol., p. 604–609. Stuttgart: G. Thieme 1960.Google Scholar
  16. ICEP, Committee III. Protection against x-rays up to energies of 3 MeV and Beta-and Gammarays from sealed sources. London: Pergamon Press 1960.Google Scholar
  17. Johns, H. E., J. W. Hunt and L. D. Skarsgard: A caesium-137 teletherapy unit for use at a source-to-skin distance of 35 cm. Brit. J. Eadiol. 32, 224–232 (1959).Google Scholar
  18. Lidén, K.: A 10-curie Co60telegamma unit. Acta radiol. (Stockh.) 38, 139–142 (1952).CrossRefGoogle Scholar
  19. Lindell, B., and E. Walstam: A new telegamma apparatus. Acta radiol. (Stockh.) 45, 236–248 (1956).CrossRefGoogle Scholar
  20. Mayneord, M. V.: A dose contour projector and its application to three-dimensional radiation distributions. Brit. J. Eadiol. 12, 262–268 (1939).Google Scholar
  21. Mitchell, J. S.: Appliactions of recent advances in nuclear physics to medicine. Brit. J. Eadiol. 19, 481–487 (1946).Google Scholar
  22. Mitchell, J. S.: Studies in radiotherapeutics, p. 181–253. Oxford: Blackwell Scientific Publ. 1960.Google Scholar
  23. NB8, Handbook 73. Protection against radiations from sealed gamma sources. U.S. Dept. of Commerce 1960.Google Scholar
  24. Sievert, E. M.: Eine Methode zur Messung von Eöntgen-, Eadium-und Ultrastrahlung nebst einige Untersuchungen über die Anwendbarkeit derselben in der Physik und Medizin. Acta radiol. (Stockh.) Suppl. 14 (1932).Google Scholar
  25. Sievert, E. M.: Two arrangements for reducing irradiation dangers in teleradium treatment. Acta radiol. (Stockh.) 18, 157–162 (1937).CrossRefGoogle Scholar
  26. Spiers, F. W.: Personal communications 1960.Google Scholar
  27. Walstam, E.: A method for three-dimensional dose-finding in teleradium therapy. Acta radiol. (Stockh.) 43, 477–486 (1955).CrossRefGoogle Scholar
  28. Spiers, F. W.: Studies on therapeutic short-distance and intracavitary gamma beam techniques. Acta radiol. (Stockh.), Suppl. 236 (1965).Google Scholar
  29. Wheatley, B. M., J. C. Jones and T. C. Sinclair: A caesium-137 beam therapy unit. Brit. J. Eadiol. 33, 251–257 (1960).Google Scholar
  30. Wilson, C.W.: Eadium teletherapy. In: Eadium therapy, p. 159–195. London: Chapman and Hall 1945.Google Scholar
  31. Zdansky, E.: Ein 60Co-Gerät für Halbtiefen und Tiefentherapie. Strahlentherapie 102, 422–424 (1957).PubMedGoogle Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 1971

Authors and Affiliations

  • O. Dahl
  • B. Mårtenson
  • R. Walstam

There are no affiliations available

Personalised recommendations