Abstract
Some 25 years after the implantation of a substitute cardiac valve, the choice of a prosthesis still remains difficult and controversial. However, progress has been made in creating new models of cardiac valvular prostheses and we are somewhat closer to the “ideal prosthesis” which should have physiological hemodynamics, be thromboresistant, and have lifetime durability (1). After using ball, disc and biological prostheses, we began at the San Camillo Hospital in Rome to use the St. Jude Medical® (SJM) bileaflet valve in 1978, after we had learned from in vitro studies about the favorable hemodynamics of the valve (2). This report will give clinical and practical data on this prosthesis from the Cardiac Surgery Center at San Camillo Hospital in Rome.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Roberts WC (1976) Choosing a substitute cardiac valve: type, size, surgeon. Ann J Cardiol 38: 633
Emery RW, Nicoloff DM (1979) St. Jude Medical cardiac valve prosthesis. In vitro studies. J Thorac Cardiovasc Surg 78: 269
Scotten NL, Racca RG, Nugent AH et al (1981) New tilting disc cardiac valve prostheses. J Thorac Cardiovasc Surg 82: 136
Horstkotte D, Haerten K, Seipel L et al (1983) Central hemodynamics at rest and during exercise after mitral valve replacement with different prostheses. Circulation 68 (Stipp’ II): 161
Bruss KH, Reul H, van Gilse J et al (1983) Pressure drops and velocity fields at four mechanical heart valve prostheses: Björk-Shiley Standard, Björk-Shiley convex-concave, Hall-Kaster, and St. Jude Medical. Life Supp Syst 1: 3
Konno S, Imai Y, Iida Y et al (1975) A new method for prosthetic valve replacement in congenital aortic stenosis associated with hypoplasia of the aortic ring. J Thorac Cardiovasc Surg 70: 909
New York Heart Association (1964) The Criteria Committee of the New York Heart Association: Diseases of Heart and Blood Vessels (nomenclature and criteria of diagnosis), 6th ed. Little, Brown and Co, Boston
Horstkotte D, Haerten K, Schulte HD et al (1983) Hemodynamical findings at rest and during exercise after implantation of different mitral valve prostheses with equal tissue annulus diameters. Z Kardiol 72: 385
Horstkotte D, Aul C, Seipel L et al (1983) Influence of valve type and valve function on chronic intravascular hemolysis following mitral and aortic valve replacement using alloprostheses. Z Kardiol 72: 119
D’Alessandro LC (1981) St. Jude Medical prosthesis: Clinical results. Second International Symposium, San Diego
D’Alessandro LC, Baruffi E, Giordano F et al (1983) Italian experience with the St. Jude Medical valve. In: DeBakey ME (ed) Advances in Cardiac Valves. Yorke Medical Books, New York p 41
Emery RW, Anderson RW, Lindsay WG et al (1979) Clinical and hemodynamic results with the St. Jude Medical aortic valve prosthesis. Surg Forum 30: 235
Horstkotte D, Haerten K, Herzer JA et al (1981) Preliminary clinical and hemodynamic results after mitral valve replacement using St Jude Medical prostheses in comparison with the BjörkShiley valve. J Thorac Cardiovasc Surg 29: 93
Gill CC, King HC, Lytle BW et al (1982) Early clinical evaluation after aortic valve replacement with the St. Jude Medical valve in patients with a small aortic root. Circulation 66 (Part II): 147
Nicoloff DM, Emery RW, Arom KV et al (1981) Clinical and hemodynamic results with the St. Jude Medical cardiac valve prosthesis. A three-year experience. J Thorac Cardiovasc Surg 82: 674
Wortham DC, Tri TB, Bowen TE (1981) Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic anulus. J Thorac Cardiovasc Surg 81: 61
Hunt D, Sloman G, Sutton L (1981) The St. Jude Medical valve: The Australian experience. Med J Aust 2: 276
Lillehei C (1982) Worldwide experience with the St. Jude Medical valve prosthesis: Clinical and hemodynamic results. Cardiovasc Med 1: 309
Chaux A, Gray RJ, Matloff JM et al (1981) An appreciation of the new St. Jude valvular prosthesis. J Thorac Cardiovasc Surg 81: 202
Garcia-Fernandez MA, Actigao R, Banuelos F et al (1982) M-mode and 2-dimensional echocardiography of the St. Jude prosthesis. Rev Esp Cardio 35: 123
Castaneda ZW, Nicoloff DM, Jorgensen C et al (1980) In vivo radiographic appearance of the St. Jude valve prosthesis. Radiology 134: 775
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1986 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
D’Alessandro, L.C. et al. (1986). The Use of Mechanical Valves in the Treatment of Valvular Heart Disease. In: Horstkotte, D., Loogen, F. (eds) Update in Heart Valve Replacement. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-662-10713-3_5
Download citation
DOI: https://doi.org/10.1007/978-3-662-10713-3_5
Publisher Name: Steinkopff, Heidelberg
Print ISBN: 978-3-662-10715-7
Online ISBN: 978-3-662-10713-3
eBook Packages: Springer Book Archive