Abstract
Measurement uncertainty in the proposed redox-potentiometric methods for peroxide value (PV) determination in vegetable oils is evaluated in comparison with uncertainty in the standard methods. The methods determine all peroxides in oils, in terms of milliequivalents per kg of sample (meq/kg), that oxidize potassium iodide (KI) under the conditions of the test. The standard methods are based on KI oxidation by the oil test portion and volumetric titration of the liberated iodine, while the proposed methods are using redoxpotentiometric iodine determination without titration. As far as fresh refined oils have PV≤0.5 meq/kg, the limit of detection (LOD) and limit of quantitation (LOQ) of the methods are important. An approach to assess the LOD and LOQ using uncertainty calculation was applied. It is shown how important is the influence of the solvents purity on the values of LOD and LOQ.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
EURACHEM (1998) EURACHEM Guide. The fitness for purpose of analytical methods. A laboratory guide to method validation and related topics, 1st edn. Teddington, UK 5.
Kuselman I, Sherman F (1999) Accred Qual Assur 4: 124–128
Kardash-Strochkova E, Tur’yan Ya, Kuselman I (2001) Talanta 54: 411–416 6.
AOCS (1996) AOCS official methods, vol II, method Cd 8–53: Peroxide value. Acetic acid-chloroform method. AOCS, Champaign, IL, USA
AOCS (1996) AOCS Official methods, vol II, method Cd 8b - 90: Peroxide val¬ue. Acetic acid-isooctane method. AOCS, Champaign, IL, USA
Finne G, Ikins WG, Williams J Jr, Welborn JL (1998) Inside Lab Manage 2: 24–26
Israel Standard No 216 (1994) Edible vegetable oils. Tel Aviv, Israel
EURACHEM/CITAC (2000) EURA¬CHEM/CITAC Guide. Quantifying un¬certainty in analytical measurement, 2nd edn. Teddington, UK
ISO (1999) ISO/DIS 8655–6 Draft. Piston-operated volumetric apparatus. Part 6: Gravimetric test methods. Geneva, Switzerland
AOCS (1996) AOCS official methods, vol II, method Ja 8–87: Peroxide value. AOCS, Champaign, IL, USA
AOAC (1997) AOAC peer-verified methods program. Manual on policies and procedures. AOAC, Gaithersburg, MD
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Kuselman, I., Kardash-Strochkova, E., Tur’yan, Y.I. (2002). Uncertainty and other metrological parameters of peroxide value determination in vegetable oils. In: De Bièvre, P., Günzler, H. (eds) Measurement Uncertainty in Chemical Analysis. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-05173-3_48
Download citation
DOI: https://doi.org/10.1007/978-3-662-05173-3_48
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-07884-2
Online ISBN: 978-3-662-05173-3
eBook Packages: Springer Book Archive