Skip to main content

Deep Autofocus with Cone-Beam CT Consistency Constraint

  • Conference paper
  • First Online:
Bildverarbeitung für die Medizin 2020

Zusammenfassung

High quality reconstruction with interventional C-arm conebeam computed tomography (CBCT) requires exact geometry information. If the geometry information is corrupted, e. g., by unexpected patient or system movement, the measured signal is misplaced in the backprojection operation. With prolonged acquisition times of interventional C-arm CBCT the likelihood of rigid patient motion increases. To adapt the backprojection operation accordingly, a motion estimation strategy is necessary. Recently, a novel learning-based approach was proposed, capable of compensating motions within the acquisition plane. We extend this method by a CBCT consistency constraint, which was proven to be effcient for motions perpendicular to the acquisition plane. By the synergistic combination of these two measures, in and out-plane motion is well detectable, achieving an average artifact suppression of 93 %. This outperforms the entropy-based state-of-the-art autofocus measure which achieves on average an artifact suppression of 54%.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. Powers WJ, et al. 2015 AHA/ASA focused update of the 2013 guidelines for the early management of patients with acute ischemic stroke regarding endovascular treatment. Stroke. 2015;46(10):3020–3035.

    Google Scholar 

  2. Berkhemer ea. A randomized trial of intraarterial treatment for acute ischemic stroke. NEJM. 2015;372(1):11–20.

    Google Scholar 

  3. Leyhe JR, Tsogkas I, Hesse AC, et al. Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT. JNIS. 2017;9(12):1253–1257.

    Google Scholar 

  4. Psychogios M, Behme D, Schregel K, et al. One-Stop management of acute stroke patients: minimizing door-to-reperfusion times. Stroke. 2017;.

    Google Scholar 

  5. Sisniega A, Stayman JW, Yorkston J, et al. Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion. Phys Med Biol. 2017;62(9):3712.

    Google Scholar 

  6. Wicklein J, Kunze H, Kalender WA, et al. Image features for misalignment correction in medical at-detector CT. Med Phys. 2012;39(8):4918–4931.

    Google Scholar 

  7. Ouadah S, Stayman W, Gang J, et al. Self-Calibration of cone-beam CT geometry using 3D–2D image registration. Phys Med Biol. 2016;61(7):2613.

    Google Scholar 

  8. Frysch R, Rose G. Rigid motion compensation in c-arm CT using consistency measure on projection data. Proc. 2015; p. 298–306.

    Google Scholar 

  9. Preuhs A, Maier A, Manhart M, et al. Symmetry prior for epipolar consistency. IJCARS. 2019;14(9):1541–1551.

    Google Scholar 

  10. Bier B, Aschoff K, Syben C, et al. Detecting anatomical landmarks for motion estimation in weight-bearing imaging of knees. MLMIR. 2018; p. 83–90.

    Google Scholar 

  11. Bier B, Unberath M, Zaech JN, et al. X-Ray-Transform invariant anatomical landmark detection for pelvic trauma surgery. Proc. 2018; p. 55–63.

    Google Scholar 

  12. Preuhs A, Manhart M, Roser P, et al. Image quality assessment for rigid motion compensation. MedNeurIPS. 2019;.

    Google Scholar 

  13. Aichert A, Berger M, Wang J, et al. Epipolar consistency in transmission imaging. TMI. 2015;34(11):2205–19.

    Google Scholar 

  14. Feldkamp L, Davis L, Kress J. Practical cone-beam algorithm. J Opt Soc Am A. 1984;1(6):612–619.

    Google Scholar 

  15. Defrise M, Clack R. A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection. TMI. 1994;13(1):186–195.

    Google Scholar 

  16. Preuhs A, Manhart M, Maier A. Fast epipolar consistency without the need for pseudo matrix inverses. CT-Meeting. 2018; p. 202–205.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexander Preuhs .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Fachmedien Wiesbaden GmbH, ein Teil von Springer Nature

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Preuhs, A. et al. (2020). Deep Autofocus with Cone-Beam CT Consistency Constraint. In: Tolxdorff, T., Deserno, T., Handels, H., Maier, A., Maier-Hein, K., Palm, C. (eds) Bildverarbeitung für die Medizin 2020. Informatik aktuell. Springer Vieweg, Wiesbaden. https://doi.org/10.1007/978-3-658-29267-6_34

Download citation

Publish with us

Policies and ethics