Earth wire selection

  • Friedrich Kiessling
  • Peter Nefzger
  • João Felix Nolasco
  • Ulf Kaintzyk
Part of the Power Systems book series (POWSYS)

Abstract

Most overhead transmission lines having voltages of 110 kV and above are provided with earth wires (or ground wires). In this context, the term earth wire is used for all types of conductors on earth potential according to EN 50 341-1, although all earth wire designs consist of a multitude of individual strands. The main purpose of the earth wires is the protection of the conductors against the direct incidence of lightning strokes, that can cause line outages (see Chapter 4). However, lightning strokes, even when reaching the earth wires, may cause a voltage rise at the towers high enough to cause a back-flashover from the tower to the conductor along the insulator set. Thus, in order to minimize the occurrence of flashovers along the insulator sets, beside using earth wires, it is necessary to reduce the voltage increase on the towers; this can be obtained through an appropriate earthing of the towers either by counterpoise wires, by deep rods or other means (see Chapter 5).

Keywords

Zinc Convection Welding Europe Attenuation 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 8.1
    D’Ajuz, A. et al.: Energized overhead ground wires - OHGW: The pioneer Brazilian application. IVth SEPODE, Foz do Iguaçu, 1994Google Scholar
  2. 8.2
    Cigré SC22 WG22–12: The thermal behaviour of overhead conductors. Section 4: Mathematical model for calculation of conductor temperature in the adiabatic state. Electra 185, (1999), pp. 75 to 87Google Scholar
  3. 8.3
    EN 60 865–1: Short-circuit currents – Calculation of effects. Part 1: Definitions and calculation methods (IEC 60865–1). Brussels, CENELEC, 1994Google Scholar
  4. 8.4
    EN 50 341–3-4: Overhead electrical lines exceeding AC 45 kV. Part 3–4: National Normative Aspects for Germany. Brussels, CENELEC, 2001Google Scholar
  5. 8.5
    EN 60071–1: Insulation coordination. Part 1: Definitions, principles and rules (IEC 60071–1). Brussels, CENELEC, 1995Google Scholar
  6. 8.6
    DIN 48 201, Part 3: Steel stranded conductors. Berlin, DKE, 1994Google Scholar
  7. 8.7
    EN 50 182: Conductors for overhead lines – Round wire concentric-lay stranded conductors. Brussels, CENELEC, 2000Google Scholar
  8. 8.8
    Mahlke, G.; Gössing, P.: Aerial cables with optical fibres. Munich – Erlangen, Publicis Corperate Publishing, 5th edition 1998Google Scholar
  9. 8.9
    IEC 60 794: Optical fibre cables. Part 1–1: Generic specifications; General. Geneva, IEC, 2001Google Scholar
  10. 8.10
    IEC 60 794–1-2: Optical fibre cables. Part 1–2: Generic specification – Basic optical cable test procedures. Genova, IEC, 1999Google Scholar
  11. 8.11
    IEC 60 794–2: Optical fibre cables. Part 2: Product specifications, Geneva, IEC, 1989Google Scholar
  12. 8.12
    IEC 60 794–3: Optical fibre cables. Part 3: Sectional specifications on outdoor cables. Geneva, IEC 1998Google Scholar
  13. 8.13
    ASTM E8: Standard for All-Dielectric Self-Supporting (ADSS) optic cable for use on overhead utility lines. New York, ASTM, 1997Google Scholar
  14. 8.14
    Cigré SC22, WG22–11: Guide to fittings for optical cables on transmission lines. Part 2B: Testing procedures, all-dielectric self-supporting cable fittings and optical attached cable fittings. Electra 191 (2000), pp. 63 to 75Google Scholar
  15. 8.15
    Cigré SC35 WG35–04: Preventive and corrective maintenance for optical cables on overhead power lines. Paris, Cigré Brochure 133, 2000Google Scholar
  16. 8.16
    EN 61284: Overhead lines – Requirements and tests for fittings (IEC 61284). Brussels, CENELEC, 1998Google Scholar
  17. 8.17
    Cigré SC22 WG22–11: Guide to fittings for optical cables on transmission lines. Part 1: Selection and use. Electra 176 (1998), pp. 55 to 65Google Scholar
  18. 8.18
    Cigré SC22 WG22–11: Guide to fittings for optical cables on transmission lines. Part 2A: Testing procedures for optical ground wire fittings and optical phase conductor fittings. Electra 188 (2000), pp. 43 to 53Google Scholar
  19. 8.19
    IEC 60 794–1-4: Optical fibre cables. Part 1: Generic specifications – Section 4: Measuring methods for transmission and optical characteristics. Geneva, IEC, 1995Google Scholar
  20. 8.20
    IEC 60794–4-1: Optical fibre cables. Part 4–1: Aerial optical cables for high-voltage power lines. Geneva, IEC, 1999Google Scholar
  21. 8.21
    Ghannoum, E. et al.: Design, testing and validation of optical ground wires and hardware for use in Hydro-Quebec’s 5000 km of telecommunication network. Cigré Report 22–301, 1996Google Scholar

Copyright information

© Springer-Verlag Berlin Heidelberg 2003

Authors and Affiliations

  • Friedrich Kiessling
    • 1
  • Peter Nefzger
    • 2
  • João Felix Nolasco
    • 3
  • Ulf Kaintzyk
    • 4
  1. 1.BaiersdorfGermany
  2. 2.HemmingenGermany
  3. 3.Belo HorizonteBrasil
  4. 4.Siemens AGPower Transmission and DistributionErlangenGermany

Personalised recommendations