Skip to main content

Administration of Contrast Media

  • Chapter
Contrast Media in Practice
  • 56 Accesses

Abstract

It seems, from first principles, entirely reasonable that CM which are, generally speaking, injected into patients in high concentrations and large doses might be better tolerated if delivered at body temperature. Many radiologists use one of the commercially available thermostatically controlled heating cabinets to warm their CM to 37°C. In any case, toxicity and tolerance aside, warming the CM to body temperature significantly reduces its viscosity, making injection easier, particularly with small needles and catheters [1].

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 74.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Halsell RD (1987) Heating contrast media in role contemporary angiography. Radiology 164: 276–278

    PubMed  CAS  Google Scholar 

  2. Turner E, Kentner P, Melamed JL, Rao G, Seitz MJ (1982) Frequency of anaphylactoid reactions during intravenous urography with radiographic contrast media at two different temperatures. Radiology 143: 327–329

    PubMed  CAS  Google Scholar 

  3. Wilcox J, Sage MR (1984) Is viscosity important in the production of blood-brain-barrier disruption by intracarotid contrast media? Neuroradiology 26: 511–513?

    Article  PubMed  CAS  Google Scholar 

  4. Ansell G (1987) Radiological contrast media. In: Inman WHW (ed) Monitoring for drug safety, 2nd ed. MTP Press, Lancashire, pp 337–348

    Google Scholar 

  5. Dawson P, Hemingway A (1987) Contrast doses in interventional radiology. J Intervent Radiol 2: 145–146

    Google Scholar 

  6. Bernstein EF, Palmer JD, Aaberg TA, Davis RL (1961) Studies on the toxicology of Hypaque-90% following rapid venous injection. Radiology 76: 88–95

    Google Scholar 

  7. Davies P, Roberts MB, Roylance J (1975) Acute reactions to urographic contrast media. BMJ 2: 434–437

    Article  PubMed  CAS  Google Scholar 

  8. Lorenz W, Doericke A (1985) Hist-amino libération induite par les produits anésthesique ou leurs solvants: spécifique ou non-spécifique. Ann Fr Anesth Reanim 4: 115–123

    Article  PubMed  CAS  Google Scholar 

  9. Pfister RC, Hutter AM (1982) Alteration in heart rate and rhythm at urography with sodium diatrizoate. Acta Radiologica 23: 107–110

    Google Scholar 

  10. Shehadi WM (1975) Adverse reactions to intravascularly administered contrast media. AJR 124: 145–152

    CAS  Google Scholar 

  11. Dawson P et al (1986) Contrast, coagulation and fibrinolysis. Invest Radiol 21: 248–252

    Article  PubMed  CAS  Google Scholar 

  12. Dawson P (1988) Non-ionic contrast agents and coagulation. Invest Radiol 23: 310–317

    Article  Google Scholar 

  13. Dawson P, Strickland NS (1991) Thromboembolic phenomena in clinical angiography: role of materials and technique. JVIR (in press)

    Google Scholar 

  14. Hawkins IF, Herbeth (1974) Contrast material used as a catheter flushing agent: a method to reduce clot formation during angiography. Radiology 110: 351–352

    PubMed  Google Scholar 

  15. Miller DL (1989) Heparin in angiography: current patterns of use. Radiology 172: 1007–1011

    PubMed  CAS  Google Scholar 

  16. Robertson HJF (1987) Blood clot formation in angiographic syringes containing non-ionic contrast media. Radiology 162: 621–622

    PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1993 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Dawson, P., Skalpe, I.O., Taenzer, V. (1993). Administration of Contrast Media. In: Dawson, P., Clauß, W. (eds) Contrast Media in Practice. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-97530-1_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-97530-1_7

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-57187-2

  • Online ISBN: 978-3-642-97530-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics