Abstract
It seems, from first principles, entirely reasonable that CM which are, generally speaking, injected into patients in high concentrations and large doses might be better tolerated if delivered at body temperature. Many radiologists use one of the commercially available thermostatically controlled heating cabinets to warm their CM to 37°C. In any case, toxicity and tolerance aside, warming the CM to body temperature significantly reduces its viscosity, making injection easier, particularly with small needles and catheters [1].
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Halsell RD (1987) Heating contrast media in role contemporary angiography. Radiology 164: 276–278
Turner E, Kentner P, Melamed JL, Rao G, Seitz MJ (1982) Frequency of anaphylactoid reactions during intravenous urography with radiographic contrast media at two different temperatures. Radiology 143: 327–329
Wilcox J, Sage MR (1984) Is viscosity important in the production of blood-brain-barrier disruption by intracarotid contrast media? Neuroradiology 26: 511–513?
Ansell G (1987) Radiological contrast media. In: Inman WHW (ed) Monitoring for drug safety, 2nd ed. MTP Press, Lancashire, pp 337–348
Dawson P, Hemingway A (1987) Contrast doses in interventional radiology. J Intervent Radiol 2: 145–146
Bernstein EF, Palmer JD, Aaberg TA, Davis RL (1961) Studies on the toxicology of Hypaque-90% following rapid venous injection. Radiology 76: 88–95
Davies P, Roberts MB, Roylance J (1975) Acute reactions to urographic contrast media. BMJ 2: 434–437
Lorenz W, Doericke A (1985) Hist-amino libération induite par les produits anésthesique ou leurs solvants: spécifique ou non-spécifique. Ann Fr Anesth Reanim 4: 115–123
Pfister RC, Hutter AM (1982) Alteration in heart rate and rhythm at urography with sodium diatrizoate. Acta Radiologica 23: 107–110
Shehadi WM (1975) Adverse reactions to intravascularly administered contrast media. AJR 124: 145–152
Dawson P et al (1986) Contrast, coagulation and fibrinolysis. Invest Radiol 21: 248–252
Dawson P (1988) Non-ionic contrast agents and coagulation. Invest Radiol 23: 310–317
Dawson P, Strickland NS (1991) Thromboembolic phenomena in clinical angiography: role of materials and technique. JVIR (in press)
Hawkins IF, Herbeth (1974) Contrast material used as a catheter flushing agent: a method to reduce clot formation during angiography. Radiology 110: 351–352
Miller DL (1989) Heparin in angiography: current patterns of use. Radiology 172: 1007–1011
Robertson HJF (1987) Blood clot formation in angiographic syringes containing non-ionic contrast media. Radiology 162: 621–622
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1993 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Dawson, P., Skalpe, I.O., Taenzer, V. (1993). Administration of Contrast Media. In: Dawson, P., Clauß, W. (eds) Contrast Media in Practice. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-97530-1_7
Download citation
DOI: https://doi.org/10.1007/978-3-642-97530-1_7
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-57187-2
Online ISBN: 978-3-642-97530-1
eBook Packages: Springer Book Archive