Abstract
Over the last 10 years more than 1000 intrathoracic transplant procedures have been performed at the German Heart Institute Berlin, 840 of which were orthotopic heart transplantations. From early on, it became apparent that medical treatment alone would not be sufficient for supporting patients through an ever-expanding waiting period before transplantation (1, 2, 3, 5–7).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Frazier OH, Macris MP (1994) Current methods for circulatory support. Texas Heart Institute Journal. 1994; 21:288–95.
Friedel N, Viazis P, Schiessler A, Warnecke H, Hennig E, Hetzer R (1991) Patient selection for mechanical circulatory support as a bridge to cardiac transplantation. Int J Art Organs 14:276–279.
Hetzer R, Hennig E, Schiessler A, Friedel N, Warnecke H, Adt M (1992) Mechanical circulatory support and heart transplantation. J. Heart Lung Transplant; 11:175–181.
Loebe M, Hetzer R, Schüler S, Hummel M, Friedel N, Weng Y, Schiessler A (1992) Herztransplantation-Indikation und Ergebnisse. Zentrbl Chir 117:681–688.
Loebe M, Weng Y, Alexi-Meskishvili V, Hausdorf G, Hennig E, Schüler S, Wamecke H, Hetzer R (1993) Mechanical circulatory support as a bridge to transplantation in children. J. Heart Lung Transplantation 12:S85
Müller J, Wallukat G, Wenig Y, Siniawski H, Hofmeier M, Kupetz W, Hetzer R (1995) Effect of synchronized-non-synchronized pumping mode of (-receptor autoantibodies (RAAB) in patients with cardiac assist devices. ASAIO 41(suppl.):50
Schiessler A, Wamecke H, Friedel N, Hennig E, Hetzer R (1990) Clinical use of the Berlin biventricular assist device as a bridge to transplantation. ASAIO Trans 36: M706–708
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1997 Dr. Dietrich Steinkopff Verlag GmbH & Co. KG, Darmstadt
About this paper
Cite this paper
Loebe, M., Weng, Y., Hennig, E., Müller, J., Spiegelsberger, S., Hetzer, R. (1997). Long-term mechanical circulatory support: The Berlin Experience. In: Hetzer, R., Hennig, E., Loebe, M. (eds) Mechanical Circulatory Support. Steinkopff. https://doi.org/10.1007/978-3-642-95984-4_17
Download citation
DOI: https://doi.org/10.1007/978-3-642-95984-4_17
Publisher Name: Steinkopff
Print ISBN: 978-3-642-95986-8
Online ISBN: 978-3-642-95984-4
eBook Packages: Springer Book Archive