Abstract
We have investigated systematically the dependence of ablation efficency on laser pulse duration, pulse energy, number of applied pulses, and fluence using freshly slaugthered rib bone samples immersed in water. The 308 nm radiation was guided by a tapered quartz fiber. The conically shaped front part reduces the laser fluence and avoids surface damage in the launching section of the optical fiber. Laser lesions were examined by scanning laser and scanning electron microscopy. No carbonisation was observed; the temperature increase of the tissue was below 40°C in the surroundings of the laser spot. Laser pulse duration was increased in steps of 30 ns up to 220 ns.The ablation rate increased linearly with applied pulse energy, but did not depend on the pulse duration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
R. Jahn, W. Lierse, W. Neu, K.H. Jungbluth: Macroscopic and microscopic results using excimer laser on various tissue. Lasermedizin 8, 38 (1992)
M. Dressel, W. Neu, H. Gerhardt: Fused silica fibers for transmitting high power excimer laser pulses. Laser und Optoelektronik 22(5), 76 (1990)
K.O. Greulich, H. Hitzler, N. Leclerc, J. Wolfrum, K.F. Klein: Transport of high-power UV-pulses through fibers with variable cross section (taper). Laser und Optoelektronik 20(4), 58 (1988).
R. Jahn, M. Dressel, H. Fabian, H. Gerhardt, J. Kesper, K.F. Klein, H.U. Langendorff, W. Neu, U. Sowada, K.H. Jungbluth: Excimer laser and tapered fibers — A break-through in fiber assisted cartilage and bone ablation. Laser Med. Surg. 6(2), 77 (1990)
K.F. Klein, G. Hillrichs, W. Neu, H. Fabian, U. Grzesik: UV-Laserlichtübertragung mit Quarzglasfasern — Stand der Technik. In: Laser. Technologie und Anwendungen. Jahrbuch 1993. Hrsg. H. Kohler. Essen: Vulkan-Verlag 1993 (im Druck)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1994 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Neu, W., Hillrichs, G., Jahn, R., Jungbluth, K.H., Tschirner, B. (1994). Ablation of Hard Biological Tissue: Dependence on XeCl Excimer Laser Parameters. In: Waidelich, W., Waidelich, R., Hofstetter, A. (eds) Laser in der Medizin / Laser in Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-93548-0_66
Download citation
DOI: https://doi.org/10.1007/978-3-642-93548-0_66
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-57441-5
Online ISBN: 978-3-642-93548-0
eBook Packages: Springer Book Archive