Abstract

To study the influence of vitamin A on hearing we choose to examine ECoGs induced by an audible stimulus.The basis of this project is a suitable experimental equipment for inducing and recording inner ear electrical responses in guinea pigs. The problem to be studied asks for a high number of animals and measurements within one animal; furthermore the ECoGs of each animal have to be examined over a long period of time. This calls for a simple and automated measurement and evaluation procedure. In contrats to most ECoG experiments we do not study the influence of special oto — toxic agents (noise,drugs etc) but examine the variation of ECoG signals as caused by different metabolic states of vitamin A.Consequntly only slight variations in the electrophysiological signals are expected.This demands for an exact and hicihly reliable measurement apparatus.To fullfill these requirements we choose to design a highly computorised equipment.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1982 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Wellner, U., Biesalski, H.K., Harth, O. (1982). A Computerised System for Electrocochleographic (ECOG) Measurement. In: O’Moore, R.R., Barber, B., Reichertz, P.L., Roger, F. (eds) Medical Informatics Europe 82. Lecture Notes in Medical Informatics, vol 16. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-93201-4_42

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-93201-4_42

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-11208-2

  • Online ISBN: 978-3-642-93201-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics