Abstract
Hitherto numerous publications concerning the analytical application of Secondary Ion Mass Spectroscopy (SIMS) have appeared. In contrast, a rather limited number of investigations dealing with the influence of instumental effects on quantitative analysis have been published till now. One of these is the interpretation of the results of the comparative SIMS study of selected glasses NEWBURY showed that the relative sensitivity factors for the same element obtained by 22 different laboratories vary over more than one order of magnitude. Under the assumption that well characterized standards had been distributed to all cooperating laboratories the main reasons for deviations of such an extent must be supposed in different primary ion (PI) beam parameters and instrumental conditions incomparable to each other. Solely standardized conditions for creation, extraction, analysis, and detection of the secondary ions (SI) and mathematical compensation of every discriminating effect will lead to data that can be handled successfully by quantitative models.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
D.E. Newbury, In Secondary Ion Mass Spectrometry SIMS-II, ed. by A. Benninghoven, C.A. Evans, Jr., R.A. Powell, R. Shimizu, H.A. Storms, Springer Series in Chemical Physics, Vol. 9 (Springer, Berlin,Heidelberg,New York 1979) o. 53
G. Slodzian, Surf. Sci. 48, 161 (1975)
G. Slodzian, Ann. Phys. 9, 591 (1964)
G. Slodzian, NBS-Publ. Ni-. 427, Washington
M.A. Rudat and G.H. Morrison, Int. J. Mass Spectrom. and Ion Phys. 27, 249 (1978)
M.A. Rudat and G.H. Morrison, Int. J. Mass Spectrom. and Ion Phys. 29, 1 (1979)
M.A. Rudat and G.H. Morrison, Int. J. Mass Spectrom. and Ion Phys. 32, 53 (1979)
M.A. Rudat and G.H. Morrison, Surf. Sci. 82, 549 (1979)
M.A. Rudat and G.H. Morrison, Anal. Chim. Acta 112, 1 (1979)
H.W. Werner and A.E. Morgan, J. Appl. Phys, 47, 1232 (1976)
G.B. Hagen, Ann. de Phys. 6/13, 1, Heft 6–8 (1953)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1982 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Bedrich, W., Koch, B., Mai, H., Seidenkranz, U., Syhre, H., Voigtmann, R. (1982). Distortion of Secondary Ion Extraction Due to Sample Surface Irregularities. In: Benninghoven, A., Giber, J., László, J., Riedel, M., Werner, H.W. (eds) Secondary Ion Mass Spectrometry SIMS III. Springer Series in Chemical Physics, vol 19. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-88152-7_13
Download citation
DOI: https://doi.org/10.1007/978-3-642-88152-7_13
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-88154-1
Online ISBN: 978-3-642-88152-7
eBook Packages: Springer Book Archive