Abstract

According to Charnley, the rationale to have a 22mm head is in reducing the friction torque and the volumetric wear.

This fact is absolutely true for metal-poly coupling and partially true also for ceramic-poly, but if we employ a ceramic-ceramic coupling, a diameter of heads of 36mm doesn’t increase the volumetric wear nor the friction torque, compared with a 22 mm metal-poly coupling.

On the other hand, a bigger diameter leads to more stable artificial joints and to a wider range of motion.

In the last two years we have developed and used an acetabular component, with a 36 mm liner-head alumina-alumina coupling.

We performed a perspective study to investigate the rate of dislocation of the prostheses in the first two month after operation.

We analysed two groups: the first one (225 cases, from March 2001 to December 2002, mean age 64 years and 9 months) in which 36 mm heads were implanted, and the second (151 cases, from January 2001 to December 2002, mean age 66 years and 9 months) in which the surgical technique was the same, but heads of 28 mm were used.

We compared the number of dislocations, 2 (0,88%) in the first group and 7 (4,63%) in the second, and the data confirmed that there is a statistically significant (p=0,020) decrease in dislocations in the group of 36 mm heads.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Authors

Editor information

Hartmut Zippel Martin Dietrich

Rights and permissions

Reprints and permissions

Copyright information

© 2003 Steinkopff Verlag, Darmstadt

About this paper

Cite this paper

Giacometti-Ceroni, R., Zagra, L. (2003). Alumina-on-Alumina Coupling with 36 mm Heads. In: Zippel, H., Dietrich, M. (eds) Bioceramics in Joint Arthroplasty. Ceramics in Orthopaedics. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-642-85763-8_27

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-85763-8_27

  • Publisher Name: Steinkopff, Heidelberg

  • Print ISBN: 978-3-7985-1417-1

  • Online ISBN: 978-3-642-85763-8

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics