Skip to main content

Advanced User Interaction in Radiotherapy Planning

  • Chapter
  • 86 Accesses

Part of the book series: Research Reports Esprit ((3319,volume 1))

Abstract

We present a new system for 3D radiotherapy planning. A sophisticated user interface allows the interactive definition of treatment parameters, the simulation of the “visible” part of the treatment and the evaluation of the precalculated dose distributions. The system makes extensive use of advanced 3D visualisation and simulation techniques and introduces a new visualisation technique called Spherical View.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Bendl R (1991) Entwicklung und Implementation einer Benutzerschnittstelle zur virtuellen Strahlentherapiesimulation. Diplomarbeit, Medizinische Informatik, Universität Heidelberg

    Google Scholar 

  2. Bendl R (1993) Methoden zur computeruntersttitzten Entwicklung, Evaluation und Anwendung komplexer Bestrahlungstechniken in der dreidimensionalen Strahlentherapieplanung. Dissertation, Universität Heidelberg

    Google Scholar 

  3. Bortfeld T et. al. (1993) Decomposition of Pencil Beam Kernels for Fast Dose Calculations in Three-Dimensional Treatment Planning. Med. Phys. 20 (2): pp 311–318

    Article  Google Scholar 

  4. COVIRA (1994) Final Evaluation Report on 3D Radiotherapy Planning and Verification, The European Comission DG XIII, AIM Project A 2003, Deliverable (63) D7 /1. 7

    Google Scholar 

  5. Gademann G (1991) Anatomische und pathomorphologische Grundlagen der Magnet-Resonanz-Tomographie von Kopf-Halstumoren: Einsatz in der Präzisionsstrahlentherapie. Habilitationsschrift, Universität Heidelberg

    Google Scholar 

  6. Gademann G et. al. (1993) Dreidimensionale Bestrahlungsplanung - Untersuchungen zur klinischen Integration. Strahlentherapie und Onkologie 3: pp 159–167

    Google Scholar 

  7. Gardey K et. al. (1994) Einfluß von Naherungen auf die schnelle 3-D Dosisberechnung irregulärer Felder in der Stereotaktischen Konvergenzbestrahlung. Zeitschrift für Medizinische Physik, 4: pp 84–89

    Google Scholar 

  8. Goitein M et. al. (1983) Multi Dimensional Treatment Planning: II. Beam’s Eye View, Backprojection and Projection through CT-Sections. Int J. Radiation Oncology Biol. Phys. 9: pp 789–797

    Article  Google Scholar 

  9. Kessler ML et. al. (1994). A Graphical Simulator for Design and Verification of Computer Controlled Treatment Delivery. In: Hounsell AR et. al. (eds.), Proc. of the XI. ICCR, Manchester: pp 80–81

    Google Scholar 

  10. Kloos U et. al. (1993) An interactive 3D Visualisation System for Dynamic Radiation Treatment Planning. In: Lemke HU et. al. (eds.), Proc. of the Int. Symp. CAR 93, Berlin: pp 669–675

    Google Scholar 

  11. Pross J (1994) Modellbasierte Segmentierung von Risikoorganen des Kopfbereiches für die 3D-Bestrahlungsplanung, Dissertation, Universität Heidelberg

    Google Scholar 

  12. Schiemann T et. al. (1993). 3D Visualisation for Radiotherapy Treatment Planning; In: Lemke HU et. al. (eds.), Proc. of the Int. Symp. CAR 93, Berlin: pp 669–675

    Google Scholar 

  13. Schulze C et. al. (1994) Consideration of Inhomogeneities in Photon Beam Dose Calculation by the Scaled Kernel Superposition Method and its Importance for Clinical Practise. In: Hounsell AR et. al. (eds.), Proc. of the XI. ICCR, Manchester: pp 276–277

    Google Scholar 

  14. Schweikard A et. al. (1992). Motion Planning in Stereotaxic Radiosurgery Depart. of Comp. Science, Stanford University, Report No. STAN-CS-92–1441

    Google Scholar 

  15. Sontag M, Purdy JA, Photon Treatment Planning Collaborative Working Group (1991). State-Of-The-Art of External Photon Beam Radiation Treatment Planning. Int. J. Radiation, Oncology Biol. Phys. 21: pp 9–23

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 ECSC-EC-EAEC, Brussels-Luxembourg

About this chapter

Cite this chapter

Bendl, R., Hoess, A., Schlegel, W. (1995). Advanced User Interaction in Radiotherapy Planning. In: Pfleger, S., Gonçalves, J., Varghese, K. (eds) Advances in Human-Computer Interaction. Research Reports Esprit, vol 1. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-85220-6_25

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-85220-6_25

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-60145-6

  • Online ISBN: 978-3-642-85220-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics