Abstract

The recent advances in 3D medical imaging are the basis to develop a new generation of computer assisted tools for radiotherapy planning. The precise extraction of therapy relevant information from 3D images, 3D display of anatomical structures, more accurate placement of beams and the calculation and display of dose disributions in three dimensions are expected to contribute to enhanced local control of tumours and to help to reduce side effects. The paper reports the current state of the art in radiotherapy planning and gives recommendations for future research.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Becker, G., Lohrum, R., Werner, T., Bürkelbach, J., Németh, G, Boesecke, R., Schlegel, W., Lorenz, W.J.: Presenation and evaluation of 3D dose distributions in radiotherapy planning. In: Computer assisted Radiology, CAR’89.(H.U.Lemke, ed.), pp. 254–261, Berlin-Heidelberg-New-York: Springer 1989;

    Google Scholar 

  • Blanco, S., López-Bote, M.A. and Desco, M.: Quality assurance in radiation therapy: Systematic evaluation of errors during the radiation execution, Radioth. Oncol. 8 256–261, (1987)

    Google Scholar 

  • Bradley, W.G., Waluch, V., Yadley, R.A., Wycoff, R.R.: Comaprison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord. Radiology 152, 695–702, (1984)

    Google Scholar 

  • Einhorn, J: Recent Developments in Oncology and Prospects for the Future. In: Cancer Research and Treatment Today: Results, Trends and Frontiers (Lapis, Eckhardt, eds.), pp. 125–138, Basel, Karger: 1987

    Google Scholar 

  • Fraas, B.A. and McShan, D.L.: 3-D Treatment Planning: Overview of a clinical planning system. In: The use of computers in radiation therapy (Bruinvis, I.A.D., ed.) pp. 273–276, Amsterdam: North Holland 1987

    Google Scholar 

  • Goitein, M., Abrams, M., Multi Dimensional Treatment Planning : I. Delineation of Anatomy. International J. of Radiat. Oncol. Biol. Phys. 9, 777–787, (1983)

    Article  Google Scholar 

  • Reinstein, L.E. and Meek, A.G.: workshop on Geometric Accuracy an Reproducibility in Radiation Therapy. Int. J. Radiation Oncol. Biol. Phys. 13, 809–810, (1987).

    Article  Google Scholar 

  • Schad, L., Boesecke, R., Schlegel, W., Hartmann, G., Sturm, V., Strauß, L. and Lorenz, W.: Three dimensional image correlation of CT-, MR- and PET studies in radiotherapy treatment planning of brain tumours.J of Comp. Ass. Tomography 11, 948–954, (1987a)

    Article  Google Scholar 

  • Schad, L., Lott, S., Schmitt, F., m Sturm, V. and Lorenz, W.J.: Correction of spatial distortion in MR imaging: A prerequisite for accurate stereotaxy. J of Comp. Ass. Tomography 11, 499–505, (1987b).

    Article  Google Scholar 

  • Schad, L., Brix, G., Zuna, I., Härle, W., Lorenz, W.J. and Semmler, W.: Multiexponential proton spin-spin relaxation in MR imaging of human brain tumours. J of Comp. Ass. Tomography 13, 577–587, (1989)

    Article  Google Scholar 

  • Schlegel, W., Sturm, V.: Computer assisted Radiotherapy, Computer Assisted Stereotaxy. In: Tutorial Notes of CAR’89 (H.U.Lemke, ed.), pp. 99–110, Berlin: AMK 1989

    Google Scholar 

  • Schlegel, W.: The Use of Computers in Radiotherapy Treatment Planning. In: Tutorial Notes of CAR 85. (H.U.Lemke, ed.), pp. 47–68, Berlin: AMK 1985.

    Google Scholar 

  • Sherouse, G.W., Mosher, C.E.: User interface issues in radiotherapy CAD software. In: The use of computers in radiation therapy (Bruinvis, I.A.D., ed.), pp. 429–436, Amsterdam: North Holland 1987

    Google Scholar 

  • Suit, HD, Becht, J, Leong, J, Stracher, M, Wood, W, Verhey, L, and Goitein, M: Potential for improvement in radiation therapy. Int. J. Radiation Oncol. Biol. Phys. 14 777–785, (1988)

    Article  Google Scholar 

  • Werner, T., Herrmann, G., Schlegel, W., Lorenz, W.J.: Parallel processing in radiotherapy treatment planning. In: The use of computers in radiation therapy (Bruinvis, I.A.D., ed.), pp. 21–24, Amsterdam: North Holland 1987

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1990 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Schlegel, W. (1990). Computer Assisted Radiation Therapy Planning. In: Höhne, K.H., Fuchs, H., Pizer, S.M. (eds) 3D Imaging in Medicine. NATO ASI Series, vol 60. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-84211-5_25

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-84211-5_25

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-84213-9

  • Online ISBN: 978-3-642-84211-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics