The use of foreign bodies to support vital functions (such as intravenous devices) or to replace defective joint functions (such as hip prosthesis) carries a considerable risk of colonization and subsequent infection of the implant, a serious and potentially life-threatening adverse side effect.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Vaudaux P, Suzuki R, Waldvogel FA, Morgenthaler JJ, Nydegger UE (1984) Foreign body infection: role of fibronectin as a ligand for the adherence of Staphylococcus aureus. J Infect Dis 149:546–554

    Article  Google Scholar 

  2. Vaudaux P, Pittet D, Haeberli A, et al (1989) Host factors selectively increase staphylococcal adherence on inserted catheters: a role for fibronectin and fibrinogen/fibrin. J Infect Dis 160:865–875

    Article  PubMed  CAS  Google Scholar 

  3. Herrmann M, Vaudaux PE, Pittet D, et al (1988) Fibronectin, fibrinogen, and laminin act as mediators of adherence of clinical staphylococcal isolates to foreign material. J Infect Dis 158:693–701

    Article  PubMed  CAS  Google Scholar 

  4. Christensen GD, Simpson WA, Bisno AL, Beachey EH (1982) Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces. Infect Immun 37:318–326

    PubMed  CAS  Google Scholar 

  5. Peters G, Locci R, Pulverer G (1982) Microbial colonization of prosthetic devices. II. Scanning electron microscopy of naturally infected catheters. Zentralbl Bakteriol Parasitenkd Hyg Abt I Orig Reihe B 173:293–299

    Google Scholar 

  6. Falcieri E, Vaudaux P, Huggler E, Lew PD, Waldvogel FA (1987) Role of bacterial exopolymers and host factors on adherence and phagocytosis of Staphylococcus aureus in foreign body infection. J Infect Dis 155:524–531

    Article  PubMed  CAS  Google Scholar 

  7. Evans RC, Holmes CJ (1987) Effect of vancomycin hydrochloride on Staphylococcus epidermidis biofilm associated with silicone elastomer. Antimicrob Agents Chemother 31:889–894

    PubMed  CAS  Google Scholar 

  8. Gristina AG, Jennings RA, Naylor PT, Myrvik QN, Webb LX (1989) Comparative in vitro antibiotic resistance of surface-colonizing coagulase-negative staphylococci. Antimicrob Agents Chemother 33:813–816

    PubMed  CAS  Google Scholar 

  9. Zimmerli W, Lew DP, Waldvogel FA (1984) Pathogenesis of foreign body infection: Evidence of a local granulocyte defect. J Clin Invest 73:1191–1200

    Article  PubMed  CAS  Google Scholar 

  10. Douard MC, Arlet G, Leverger G, et al (1989) Quantitative blood cultures for diagnosis and management of catheter-related sepsis in leukemic children. 29th Interscience Conference on Antimicrobial Agents and Chemotherapy. Abstract no. 622

    Google Scholar 

  11. Maki DG, Weise CE, Sarafin HW (1977) A semiquantitative culture method for identifying intravenous catheter-related infection. N Engl J Med 296:1305–1309

    Article  PubMed  CAS  Google Scholar 

  12. Press OW, Ramsey PG, Larson EB, Fefer A, Hickman RO (1984) Hickman catheter infections in patients with malignancies. Medicine 63:189–200

    Article  PubMed  CAS  Google Scholar 

  13. Bint AJ, Finch RG, Gokal R, Goldsmith HJ, Juno B, Oliver D (1987) Diagnosis and management of peritonitis in continuous ambulatory peritoneal dialysis. Lancet 1:845–848

    Google Scholar 

  14. Bisno AL, Dismukes WE, Durack DT, et al (1982) Antimicrobial treatment of infective endocarditis due to viridans streptococci, enterococci, and staphylococci. JAMA 261:1471–1477

    Article  Google Scholar 

  15. Bisno AL (1989) Infections of central nervous system shunts. In: Bisno AL, Waldvogel FA (eds) Infections associated with indwelling medical devices. American Society for Microbiology, Washington, DC, pp 93–110

    Google Scholar 

  16. Gnann JW, Cobbs CG (1985) Infections of prosthetic valves and intravascular devices. In: Mandell GL, Douglas RG, Bennet JE (eds) Principles and practice of infectious diseases, 2nd edn. Wiley, New York, pp 530–539

    Google Scholar 

  17. Maki DG (1989) Risk factors for nosocomial infection in intensive care. ‘Devices vs. nature’ and goals for the future. Arch Intern Med 149:30–35

    Article  PubMed  CAS  Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1990 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Herrmann, M., Lew, D.P. (1990). Foreign Body Infections: From Intravenous Catheters to Hip Prosthesis. In: Vincent, J.L. (eds) Update 1990. Update in Intensive Care and Emergency Medicine, vol 10. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-84125-5_5

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-84125-5_5

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-52269-0

  • Online ISBN: 978-3-642-84125-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics