Abstract
Recent clinical reports on the possibility of continuous measurement of mixed venous oxygen saturation (Sv̄O2) have prompted a resurgence of interest in the value of this parameter as indicator of cardiorespiratory function [1–3].
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Beale PL, McMichan JC, Marsh MB, Sill JC, Sourther PY (1982) Continuous monitoring of mixed venous saturation in critically ill patients. Anesth Analg 61:513–517.
Fahey PJ, Harris K, Vanderwarf C (1984) Clinical experience with continuous monitoring of mixed venous oxygen saturation in respiratory failure. Chest 5:748–752.
Reinhart K, Moser N, Rudolph T, Gramm HJ, Goecke J (1987) Comparison of two mixed-venous saturation catheters in critically ill patients. Anesthesiology (Abst).
Shoemaker WC, Czer LSC (1979) Evaluation of the biologic importance of various hemodynamic and oxygen transport variables. Crit Care Med 7:237–245.
Fick A (1870) Über die Messung des Blutquantums in den Herzventrikeln. Sitzungsber. Phys Med Ges Würburg Bd II: XVI.
Bishop JM, Donald KW, Wade OL (1954) Minute to minute changes in cardiac output by the direct Fick method in normal subjects during exercise and recovery. J Physiol 123:12–56.
Bishop JM, Wade OL, Donald KW (1958) Changes in jugular and renal arterio-venous oxygen content difference during exercise in heart disease. Clin Sci 611-627.
Reinhart K (1988) Zum Monitoring des Sauerstofftransportsystems. Anaesthesist (in press).
Boyd AD, Tremblay RE, Spencer FC, Behnson HT (1959) Estimation of cardiac output soon after intracardiac surgery with cardiopulmonary bypass. Ann Surg 150:613–626.
Kasnitz P, Druger GL, Frederick Y, Simmons DH (1976) Mixed venous oxygen tension and hyperlactatemia: Survival in severe Cardiopulmonary disease. JAMA 236:570–577.
Kawakami Y, Kishi F, Yamamato H, Miyamoto K (1983) Relation of oxygen delivery mixed venous oxygenation and pulmonary hemodynamics to prognosis in chronic obstructive pulmonary disease. N Engl J Med 308:1045–1051.
Patt GVS, Blackstone EH, Kirklin JW (1974) Cardiac performance and mortality early after intracardiac surgery in infants and children. Circulation 51:867–873.
Schlichting R, Cowden VL, Chaitman BR (1986) Tolerance of unusually low mixed venous oxygen saturation adaptations in the chronic low cardiac output syndrome. Am J Med 80:813–818.
Jamieson WRE, Turnbull KW, Larrieu AJ, Dodds WA, Allison JC, Tyers GFO (1982) Continuous monitoring of mixed venous oxygen saturation in cardiac surgery. Canad Surg 25:538–543.
Muir AL, Kirby BJ, King AJ, Miller HC (1971) Mixed venous oxygen saturation in relation to cardiac output in myocardial infarction. Brit Med J 4:276–278.
Waller JL, Kaplan JA, Bauman DI, Craver JM (1982) Clinical evaluation of a new fiberoptic catheter oximetry during cardiac surgery. Anesth Analg 61:676–679.
Reinhart K, Gramm HJ, Specht M, Föhring U, Mayr O, Schäfer M, Dennhardt R (1986) Physiologische Grundlagen und klinische Erfahrungen mit der kontinuierlichen In vivo-Registrierung der gemischtvenösen Sauerstoffsättigung bei Risikopatienten. Intensivmed 23:346–352.
Forsyth RP, Hoffbrand BM, Melmon KL (1970) Redistribution of cardiac output during hemorrhage in the unanaesthetized monkey. Circ Res 27:311–320.
Aghdami A, Ellis R (1985) High oxygen saturation does not always indicate arterial placement of catheter during internal jugular venous cannulation. Anesthesiology 62:372–373.
Bihari D, Grimson A, Waterson M, Williams R (1984) Tissue hypoxia during fulminant hepatic failure. Crit Care Med 12:233–241.
Finley RJ, Duff JH, Holliday RL, Jones D, Marchuk JB (1975) Capillary muscle blood flow in human sepsis. Surgery 78:87–92.
McLean LD, Mulligan WG, McLean APH, Duff JH (1967) Patterns of septic shock in man. Ann Surg 166:543–562.
Conn JN, Buurk LP (1979) Nitroprusside. Ann Intern Med 91:752–765.
Moss GS, Erve PP, Schumer W (1969) Effect of endotoxin on mitochondrial respiration. Surg Forum 20:24–36.
Tinker JH, Michenfelder JD (1982) Cardiac cyanide toxicity induced by nitroprusside in the dog: potential for reversal. Anesthesiology 49:109–114.
Cole JS, Martin WE, Cheung PW, Johnson CC (1972) Clinical studies with a solid state fiberoptic oximeter. Am J Cardiol 29:383–388.
Gamble WJ, Hugenholtz PG, Monroe RG, Polanyi M (1965) The use of fiberoptics in clinical cardiac catheterization. Circulation 31:328–343.
Polanyi ML, Hehir RM (1962) In vivo oximeter with fast dynamic response. Rev Sc Instr 33:1050–1054.
Reinhrt K, Kersting K, Föhrung U, Schäfer M (1986) Can central-venous replace mixed-venous oxygen saturation measurements during anesthesia. In: Longmuir S (ed) Oxygen transport to tissue, vol 8. Plenum Press, New-York, pp 67–72.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1988 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Reinhart, K., Schäfer, M., Specht, M. (1988). Indications and Limitations of Sv̄O2 and ScvO2 Monitoring. In: Vincent, J.L. (eds) Update 1988. Update in Intensive Care and Emergency Medicine, vol 5. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-83392-2_54
Download citation
DOI: https://doi.org/10.1007/978-3-642-83392-2_54
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-18981-7
Online ISBN: 978-3-642-83392-2
eBook Packages: Springer Book Archive