Reliable Design and Operation of the ECC System for a Heavy Water Moderated Nuclear Research Reactor

  • Mirko G. Lalovic
  • Günter G. Weber
Conference paper

Abstract

Safety and reliability requirements of nuclear reactors are of considerable importance. In this paper, the reliable design and operation of the Emergency Core Cooling System (ECCS) for a heavy water cooled research reactor in the nuclear research center of Vinca (Yugoslavia) is discussed. An investigation was done for a loss of coolant accident (LOCA) with special reference to inlet and outlet pipes of the prime coolant loops.

Keywords

Novi 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. /1/.
    Lalovic, G.M., Fault Tree Constructions for ECCS of Research Reactor RA in Vinca, Proceedings of ETAN-Conference, Split 1984Google Scholar
  2. /2/.
    Birolini, A., Qualität und Zuverlässigkeit technischer Systeme, Theorie, Praxis, Management Springer Verlag, Berlin, 1985.Google Scholar
  3. /3/.
    Weber, G., Failure Dianosis and Fault Tree Analysis, KfK 3384, July 1982 Kernforschungszentrum KarlsruheGoogle Scholar
  4. /4/.
    Handbuch der Sicherheitstechnik I (Herausgeber Peters, O.H., Meyna, A.), Carl Hanser Verlag, München 1985, Kapitel 2.2. Analytische Verfahren (Boolesche Verfahren), Weber, G.Google Scholar