This paper presents results of evaluation performed on the power conversion system (PCS) of the IEA/SSPS distributed collector system (DCS). The steam generator of the PCS is fed by thermal oil coming from the storage tank. The steam runs a turbine-generator system (Stal-Laval) with a nominal electric output of 577 kw.