Abstract
Two-phase mass flow rate measurement by Pitot tubes (fixed Pitot tubes or a traversable Pitot tube) in combination with density (void fraction) measurements by a five beam gamma densitometer or a traversable impedance probe are presented. The experiments were performed in steady-state, horizontal air-water and steam-water pipe flows. Three pipe diameters of 16, 20 and 50 mm were used. The test matrix covered both high mass fluxes (dispersed flow regime with fairly axisymmetric phase and velocity distributions) and lower mass fluxes (distributions dominated by stratification due to gravity). In both cases a high degree of accuracy is obtained. In the former case, the measurement technique can be simplified without a significant decrease in accuracy by using only one Pitot tube and a single density measurement. In the latter case, the gamma densitometer can be replaced by a simple traversing impedance probe.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Adorni, N., Casagrande, J., Cravarolo, L., Hassid A., and Silvestri, H., 1961, Experimental data on two-phase adiabatic flow liquid film thickness, phase and velocity distribution, pressure drops in vertical gas liquid flow. Cise R-35.
Anderson, G.H. and Mantzouranis, B.G., 1960, Two Phase Flow Phenomena II, Liquid Entrainment, Chemical Engineering Science, Vol. 12, 233–242.
Banerjee, S., Heidrick, T.R., and Rhodes, E., 1980, Development and calibration of instruments for measurements in transient two-phase flows. Transient Two-Phase Flow, Ed. M. Reocreux and G. Katz, Vol. 2, p. 745–772.
Barasch, M., and Lahey, R.T., 1981, The Measurement of Two-Dimensional Phase Separation Phenomena, NUREG/CR-1936
Bosio, H.A. and Malnes, D., 1968, Water velocity measurements in air-water mixture, Euromech. Colloquium Mo. 7, Grenoble.
Davis, M.R., 1979, Response of Small Pitot Tubes in Gas-Liquid Flows, J. Multiphase Flow, Vol. 6, 369–373
Fincke, J.R., 1978, Development of two-phase mass flow measurements at INEL, Review Group Meeting on Two-Phase Flow Instrumentation, Troy, New York, March 13–14.
Fincke, J.R. and Deason, V.A., 1979, Mass flow rate measurement in two-phase mixtures with stagnation probes, NRC Instrumentation Review Group Meeting, Silver Spring, Maryland, July 24–26.
Gill, L.F., Hewitt, G.F., Hitchon, J.W., and Lacey, P,M.C., 1963, Sampling Probe Studies of the Gas Core in Annular Two-Phase Flow, AERE-R-39.
Hau, K.-F., and Banerjee, S., 1981, Measurement of Mass Flux in Two-Phase Flow Using Combinations of Pitot Tubes and Gamma Densitometer, AIChE Journal Vol. 27, No. 2, 177–184.
Hewitt, G.F., 1978, Measurement of two-phase flow parameters, Academic Press, London
John, H. and Reimann, J., 1979, Gemeinsamer Versuchsstand zÿm Testen und Kalibrieren verschiedener Zweiphasen-Massenstrommeßverfahren, Anlagenbeschreibung, KfK 2731 B.
John, H., Reimann, J., Alsmeyer, H., and Megerle, A., 1979, Serielles 5-Strahl-y-Densitometer zur Dichtemessung einer Zweiphasenströmung, KfK 2783..
John, H., Müller, U., and Reimann, J., 1983, Test of Two-Phase Mass Flow Rate Instrumentation in Transient Steam-Water Flow, IUTAM Symposium, July 5–8, Nancy (France)
Kedziur, F., John, H., Loeffel, R., and Reimann, J., 1980, Experimental Investigation of a Two-Phase Nozzle Flow; KfK 2902.
Malnes, D., 1966, Slip ratios and friction factors in bubbly flow regimes in vertical tubes, KR-110, Kjeller, Norway.
Neal, L.G. and Bankoff, S.G., 1965, Local parameters in co-current mercury-nitrogen flow, Symp. on Two-Phase Flow, Exeter, Paper C6.
Reimann, J., John, H. and Müller, S., 1978, Impedance Probe for Detecting Flow Regime and Measuring the Phase Distribution in Horizontal Air-Water-and Steam-Water Flow; Two-Phase Flow Instrumentation Review Group Meeting, Troy, New York, March 13–14.
Reimann, J., John, H., Demski, A., Pawlak, L., and Seeger, W., and Weinbrecht, R, 1981a, Gemeinsamer Versuchsstand zum Testen und Kalibrieren verschiedener Zweiphasen-MassenstromMeßverfahren. Projekt Nukleare Sicherheit, Jahresbericht 1980, KfK 2950.
Reimann, J., John, H., and Seeger, W., 1981b, Transition from Slug to Annular Flow in Horizontal Air-Water and Steam-Water Flow; KfK 3189.
Reimann, J., 1983, Developments in Two-Phase Mass Flow Rate Instrumentation, Advances in Two-Phase Flow and Heat Transfer, Ed. by S. Kakac and M. Ishii, Martinus Nijhoff Publishers, Vol. 1, p. 338–402
Walmet, G.E. and Staub, F.W., 1969, Pressure temperature and void fraction measurement in nonequilibrium two-phase flow. Two-Phase Flow Instrumentation, Ed. by B. Le Tourneau and A. Bergles, ASME.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Springer-Verlag Berlin, Heidelberg
About this paper
Cite this paper
Reimann, J., Kusterer, H., John, H. (1984). Two-Phase Mass Flow Rate Measurements with Pitot Tubes and Density Measurements. In: Delhaye, J.M., Cognet, G. (eds) Measuring Techniques in Gas-Liquid Two-Phase Flows. International Union of Theoretical and Applied Mechanics. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-82112-7_30
Download citation
DOI: https://doi.org/10.1007/978-3-642-82112-7_30
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-82114-1
Online ISBN: 978-3-642-82112-7
eBook Packages: Springer Book Archive