Abstract
During inhalation anaesthesia the breathing system serves to control the composition of the alveolar gas mixture. As shown in Fig. 1, the breathing system has a crucially important place in a very complex system composed of many subsystems. The breathing system is the interface between the patient and the anaesthesia system, and therefore it should be properly designed and adequately monitored.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Cooper JB, Newbower RS, Long CD, McPeek B (1978) Preventable anesthesia mishaps — a human factors study. Anesthesiology 49: 399–406
Ernst EA, MacKrell TN, Pearson JD, Cutter G, Wagenknecht L (1987) Patient safety: a comparison of open and closed anesthesia circuits. Anesthesiology 67: A474
Hamilton WK (1964) Nomenclature of inhalation anesthetic systems. Anesthesiology 25: 3–5
Aldrete J A (1984) A practical perspective on low, minimal and closed-system anesthesia. Acta Anaesthesiol Belg 34: 251–256
Foldes FF, Ceravolo AJ, Carpenter SL (1952) The administration of nitrous-oxide anesthesia in closed system. Ann Surg 136: 978–981
Virtue RW (1974) Minimal-flow nitrous oxide anesthesia. Anesthesiology 40: 196–198
Leuenberger M, Feigenwinter P, Zbinden AM (1992) The gas leakage of seven anaesthesia circle systems. Eur J Anaesthesiol 9: 121–127
Morrison JL (1994) FDA Anesthesia apparatus checkout recommendations 1993. ASA Newslett 58: 25–26
Ghani AG (1984) Fresh gas flow affects minute volume during mechanical ventilation. Anesth Analg 63: 619–625
Aldrete JA, Adolph AJ, Hanna LM, Farag HA, Ghaemmaghami M (1989) Fresh gas flow rate and I:E ratio affect tidal volume in anaesthesia ventilators. In: van Ackern K, Frankenberger H, Konecky E, Steinbereithner (eds) Quantitative anaesthesia. Anesthesiology and intensive care medicine, vol 204. Springer, Berlin Heidelberg New York, pp 72–80
Eger EI, Ethans CT (1968) The effect of inflow, overflow and valve placement on economy of the circle system. Anesthesiology 29: 93–100
Zbinden AM, Feigenwinter P, Hutmacher M (1991) Fresh gas utilization of eight circle systems. Br J Anaesth 67: 492–499
Hayes JK, Westenskow DR, East TD, Jordan WS (1984) Computer-controlled anesthesia delivery system. Med Instrum 18: 224–231
Ritchie RG, Ernst EA, Pate BL, Pearson JP, Sheppard LC (1990) Automatic control of anesthetic delivery and ventilation during surgery. Med Prog Technol 16: 61–67
Westenskow DR, Wallroth CF (1990) Closed-loop control for anesthesia breathing systems. J Clin Monit 6: 249–256
Lin CT (1980) Assessment of vaporizer performance in low-flow and closed circuit anesthesia. Anesth Analg 59: 359–366
Zbinden AM, Frei F, Westenskow DR, Thomson DA (1986) Control of end-tidal halothane concentration. Part A. Anaesthesia breathing system and feedback control of gas delivery. Br J Anaesth 58: 555–562
Zbinden AM, Frei F, Westenskow DR, Thomson DA (1986) Control of end-tidal halothane concentration. Part B. Verification in dogs. Br J Anaesth 58: 563–571
Lerou JGC, Dirksen R, Beneken Kolmer HH, Booij LHDJ (1991) A system model for closed-circuit inhalation anesthesia: I. Computer study. Anesthesiology 75: 345–355
Lerou JGC, Dirksen R, Beneken Kolmer HH, Booij LHDJ Borm GF (1991) A system model for closed-circuit inhalation anesthesia. II. Clinical validation. Anesthesiology 75: 230–237
Lerou JGC, Vermeulen PM, Dirksen R, Booij LHDJ, Borm GF (1993) The predictive performance of a system model for enflurane closed-circuit inhalational anesthesia. Anesthesiology 79: 932–942
Westenskow DR, Jordan WS, Hayes JK (1983) Uptake of enflurane: a study of the variability between patients. Br J Anaesth 55: 595–601
Barton F, Nunn JF (1975) Totally closed circuit nitrous/oxide anaesthesia. Br J Anaesth 47: 350–357
Morita S, Latta W, Hambro K, Snider MT (1992) Accumulation of methane, acetone, and nitrogen in the inspired gas during closed circuit anesthesia. Anesth Analg 64:343– 347
Ernst EA (1982) Use of charcoal to rapidly reduce alveolar anesthetic concentration while maintaining a closed circuit. Anesthesiology 57: 343
Romano E, Pegoraro M, Vacri A, Pecchiari C, Auci E (1992) Low-flow anaesthesia systems, charcoal and isoflurane kinetics. Anaesthesia 47: 1098–1099
Kim BM, Sircar S (1977) Adsorption characteristics of volatile anesthetics on activated carbons and performance of carbon canisters. Anesthesiology 46: 159–165
Capon JH (1974) A method of regenerating activated charcoal anaesthetic absorbers by autoclaving. Anaesthesia 29: 611–614
Ernst EA, MacKrell TN, Pearson JD, Cutter G, Wagenknecht L (1987) Patient safety: a comparison of open and closed anesthesia circuits. Anesthesiology 67: A474
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1995 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Booij, L.H.D.J., Lerou, J.G.C. (1995). The Differences Between Closed-Circuit, Low-Flow, and High-Flow Breathing Systems: Controllability, Monitoring, and Engineering Aspects. In: Schwilden, H., Stoeckel, H. (eds) Control and Automation in Anaesthesia. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-79573-2_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-79573-2_6
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-79575-6
Online ISBN: 978-3-642-79573-2
eBook Packages: Springer Book Archive