Large-volume Counterpulsation

  • Chapter
Assisted Circulation 4

Abstract

The intriguing principle of “counterpulsation” [1] introduced the possibility of affecting the circulation by separately interfering with the two cardiac cycles, systolic and diastolic. It derived from the observation that myocardial oxygen consumption depends on the myocardial time-tension index [2]. If, therefore, pressure during ventricular ejection could be reduced, oxygen consumption could also be reduced, provided mean arterial perfusion pressure was maintained at the same level. This principle has been used in the only method of assistance to gain acceptance as a standard clinical therapy, intra-aortic balloon pumping [3].

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Clauss R, Birtwell C, Albertal G, Lunzer S, Taylor W, Fosberg A, Harken D (1961) Assisted circulation. I. The arterial counterpulsator. J Thorac Cardiovasc Surg 41:447

    PubMed  CAS  Google Scholar 

  2. Welch G, Sarnoff S, Braunwald E, Stainsby W, Case R, Macruz R (1958) The influence of cardiac output, aortic pressure and heart rate on myocardial oxygen utilization. Surg Forum 8:294

    Google Scholar 

  3. Moulopoulos S, Topaz S, Kolff W (1962) Diastolic balloon pumping (with carbon dioxide) in the aorta: a mechanical assistance to the failing circulation. Am Heart J 62:669

    Article  Google Scholar 

  4. Moulopoulos S (1983) Mechanical cardiac assistance. In: Hurst A (ed) Clinical assays on the heart. McGraw-Hill, New York, p 233

    Google Scholar 

  5. Nanas J, Poyadjis A, Charitos C, Nanas S, Kontoyannis D, Anastasiou M, Alevizakos N, Voudris V, Moulopoulos S (1990) Additional salutary hemodynamic effects of the combined use of the paraaortic counterpulsation device and intraaortic balloon pump versus a paraaortic counterpulsation device alone. ASAIO Trans 36:505

    Google Scholar 

  6. Wiggers C (1939) Physiology in health and disease. Lea and Febiger, Philadelphia

    Google Scholar 

  7. Moulopoulos S, Stamatelopoulos S, Plassaras G, Sideris D, Hassapoyannis C (1976) A nomogram for optimal assistance by intraaortic balloon pumping. Abstracts of the 7th European Congress on Cardiology, Amsterdam, vol 1, p 708

    Google Scholar 

  8. Moulopoulos S, Anthopoulos L, Stamatelopoulos S, Boufas D (1973) Optimal changes in stroke work during left ventricular bypass. J Appl Physiol 24:12

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Moulopoulos, S.D. (1995). Large-volume Counterpulsation. In: Unger, F. (eds) Assisted Circulation 4. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-79340-0_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-79340-0_4

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-79342-4

  • Online ISBN: 978-3-642-79340-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics