Future Trends

  • K. Stangl
  • M. Laule

Abstract

The continuous detection of biosignals opens up new therapeutic and diagnostic possibilities for both fields of bradyarrhythmias and of tachyarrhythmias. However, the new technologies make high demands on the long-term stability of the sensors, the energy reserve of the system and — in particular — the “intelligence” of the pacemaker.

Keywords

Stroke Volume Sick Sinus Syndrome Pace Rate Data Drift Right Ventricular Pressure 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Alt E, Theres H, Heinz M et al. (1988) A new rate response pacemaker system optimized by combination of two sensors. PACE 11:1119PubMedGoogle Scholar
  2. 2.
    Alt E (1990) Implantable devices — pending issues and future trends. PACE 13:1079PubMedGoogle Scholar
  3. 3.
    Baig W, Boute W, Wilson J et al. (1988) Use of the paced evoked response in termination of pacing threshold. PACE 11 [Suppl]:822Google Scholar
  4. 4.
    Begeman MJS, Boute W (1988) Automatic refractory period. PACE 11 [Suppl]:820Google Scholar
  5. 5.
    Bennett T, Beck R, Erickson M (1987) Right ventricular dynamic pressure parameters for differentiation of supraventricular and ventricular rhythms. PACE 10:415Google Scholar
  6. 6.
    Boute W, Hamersma M, Vreuls P (1988) AV-delay hysteresis function in dual chamber pacemakers. PACE 11 [Suppl]:815Google Scholar
  7. 7.
    Chirife R (1988) The pre-ejection period:a physiologic signal for rate responsive pacing and tachycardia diagnosis in automatic pacemakers. PACE 11 [Suppl]:821Google Scholar
  8. 8.
    Cohen TJ, Veltri EP, Lattuca J et al. (1988) Hemodynamic responses to rapid pacing:a model for tachycardia differentiation. PACE 11 /1:1522PubMedGoogle Scholar
  9. 9.
    Eisinger GE, Winston SA, McGaughey (1988) Rate responsive AV-delay and its effect on upper rate limit performance in DDD pacemakers. PACE 11 [Suppl]:815Google Scholar
  10. 10.
    Garcia JR, Vela JCO (1988) Cardiac pacemakers assisted by computer aids. PACE 11 [Suppl]:793Google Scholar
  11. 11.
    Heinze R, Hoekstein KN, Liess HD et al. (1988) Automatische Anpassung frequenzgeregelter Herschrittmacher an die cardiale Leistungsfähigkeit von Patienten. Biomed Tech (Berlin) 39 [Suppl]:19Google Scholar
  12. 12.
    Heuer H, Koch T, Isbruch F et al. (1987) Pacemaker stimulation by a two sensor regulation. PACE 10 /11:688Google Scholar
  13. 13.
    Janosik D, Pearson A, Redd R et al. (1987) The importance of atrioventricular fallback in optimizing cardiac output during physiological pacing. PACE 10:410Google Scholar
  14. 14.
    Shapland JE, Bach S, Baumann L et al. (1988) New approaches for tachycardia discrimination. PACE 11 [Suppl]:821Google Scholar
  15. 15.
    Stangl K, Wirtzfeld A, Heinze R et al. (1985) Oxygen content and temperature of mixed venous blood as physiological parameters for regulating pacing rate. In:Gomez FP (ed) Cardiac pacing, electrophysiology. tachyarrhythmias. Grouz, Madrid, p 810Google Scholar
  16. 16.
    Stangl K, Wirtzfeld A, Heinze R et al. (1988) A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, and temperature, right atrial pressure, right ventricular pressure, and dP/dt. PACE 11:712PubMedGoogle Scholar
  17. 17.
    Stangl K (1990) Holter-Funktionen. In:Stangl K, Heuer H, Wirtzfeld A (eds) Frequenzadaptive Herzschrittmacher. Physiologie, Technologie, klinische Ergebnisse. Steinkopff, Darmstadt, p 291Google Scholar
  18. 18.
    Wirtzfeld A, Schmidt G, Himmler FC et al. (1987) Physiological pacing:present status and future developments. PACE 10:41PubMedGoogle Scholar

Copyright information

© Springer Verlag, Berlin Heidelberg 1993

Authors and Affiliations

  • K. Stangl
  • M. Laule
    • 1
  1. 1.First Medical Clinic, CharitéHumboldt UniversityBerlinGermany

Personalised recommendations