Skip to main content

Die Messung des fetalen Gefäßwiderstandes mit dem Duplexscanner — ein neuer fetaler Streßtest

  • Conference paper
Gynäkologie und Geburtshilfe 1988
  • 7 Accesses

Summary

In 77 women (Ø 41 week, lt;7 days before delivery) we compared the resistance index (RI) in the umbilical artery (UA), descending aorta (DA) and intracranial artery (ICA) with an oxytocin challenge test (OCT) and a non stress test (NST). Proof criterias were asphyxia resulting in operative deliveries and metabolic acidosis. The sensitivity in predicting metabolic acidosis was low in all tests, but a high and comparable specificity could be achieved in both the RI and OCT. In predicting fetal asphyxia the RI in the ICA had a high sensitivity, the RI in the UA and DA had the highest specificity of all tests. Centralisation and increased brain perfusion seem to detect fetal asphyxia as a result of placental insufficiency.

Zusammenfassung

Bei 77 Frauen (Ø 41 SSW, lt;7 Tage vor Geburt), wurde das Meßergebnis des Resistance Index (RI) in der Umbilikalart. (UA), desz. Aorta (DA), und einem intracran. Gefäß (ICA) mit dem Oxytozinbelastungstest (OBT) und Non-Streß-Test (NST) verglichen. Prüfkriterien waren operative Entbindung aus Asphyxiegründen bzw. met. Azidose. Die Sensitivität in der Erkennung der met. Azidose war in allen Testen niedrig, dagegen erzielten sowohl normale RI-Werte als auch ein unauffälliger OBT eine hohe Spezifität, Bei der Vorhersage der fetalen Asphyxie hatte der RI in der ICA eine hohe Sensitivität, in der UA and DA die höchste Spezifität aller Teste. Ein brain sparing Effekt scheint ein frühes Zeichen der Plazentarinsuffizienz zu sein.

Measurement of Fetal Vascular Resistance Using a Duplex Scanner - A New Fatal Stress Test

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 44.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 59.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. Farmakides G, Schulman H, Winter D, Ducey J, Guzman E, Penny B (1988) Prenatal Surveillance using nonstress testing and Doppler velocimetry. Obstet Gynecol 71: 184–186

    PubMed  CAS  Google Scholar 

  2. Trudinger BJ, Cook CM, Jones L, Giles WB (1986) A comparison of fetal heart rate moni- toring and umbilical artery waveforms in the recognition of fetal compromise. Br J Obstet Gynaecol 93: 171–175

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1989 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Schneider, K.T.M., Loos, W., Hassler, A., Graeff, H. (1989). Die Messung des fetalen Gefäßwiderstandes mit dem Duplexscanner — ein neuer fetaler Streßtest. In: Ludwig, H., Krebs, D. (eds) Gynäkologie und Geburtshilfe 1988. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-74784-7_36

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-74784-7_36

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-74785-4

  • Online ISBN: 978-3-642-74784-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics