Abstract
Both long examination times and long acquisition times have been considered significant disadvantages in the routine clinical application of MRI. Since 1985 several so-called fast-imaging pulse sequences have been developed. A number of these pulse sequences, like fast low-angle shot imaging (FLASH) and fast imaging with steady precession (FISP), are based on a steady state, using very short repetition times (TR), very short echo times (TE) produced by gradient echos, and variable flip angles (Oppelt et al. 1986; Weber et al. 1986; Frahm et al. 1986; Mills et al. 1987; Matthaei et al. 1986; Weber and Deimling 1987; Krestin et al. 1986).
This study was supported by the Deutsche Krebshilfe e.V.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Axel L, Reichek N, Schiebler M et al. (1986) Rapid small flip angle MRI: valvular insufficiency. Radiology 161 (P): 338
Buxton RB, Edelman RR, Rosen BR et al. (1987) Contrast in rapid MR imaging: Tl- and T2-weight-ed imaging. J Com. Assist Tomogr 11 (1): 7–15
Dixon WT (1984) Simple proton spectroscopic imaging. Radiology 153 (1): 189–194
Farrar TC, Becker EJ (1971) Pulse and Fourier transform NMR. Academic New York
Frahm J, Haase A, Matthaei D (1986) Rapid NMR imaging of dynamic processes using the FLASH technique. Magn Reson Med 3: 321–327
Frahm J, Merboldt KD, Hänicke W (1987) Neue Ergebnisse mit der FLASH-Tomographie. In: Lissner J, Doppman JL, Margulis AR (eds) MR’87. Schnetztor Verlag, Konstanz, 21–24
Friedmann G, Krestin G, Bunke J (1987) Kontraste an normalen und pathologischen Geweben - Gegenüberstellung Spinecho und FFE-Verfahren. In: Lissner J, Doppman JR, Margulis A (eds) MR’87. Schnetztor Verlag, Konstanz, 30–34
Harms, SE (1986) Fast imaging schemes and 3-dimensional image acquisitions. Radiology 161 (P): 77
Heywang SH, Köbrunner G, Wolf A et al. (1987) Klinische Anwendung von Fast Imaging-Techniken. In: Lissner J, Doppman JL, Margulis A (eds) MR 87 Referateband. Schnetztor, pp 35–38
Higgins CB (1987) EKG-gated cine MRI of the heart: anatomy and function. In: Lissner J, Doppman JL, Margulis A (1987) MR 87, Referateband. Schnetztor, (inpress)
Kaiser WA, Oppelt A (1987) KST der Mamma mit Schnellbildverfahren. In: Lissner J, Doppman JL, Margulis A (eds) MR 87, Referateband. Schnetztor, pp 303–310
Karis, JP, Fram EK, Johnson GA et al. (1986) Contrast-dependence in limited-angle MR imaging. Radiology 161 (P): 68
König H, Sauter R, Kueper K et al. (1986) MRI of articular cartilage disorders: specificity of fast imaging and CHESS. Radiology 161 (P): 312
Krestin GP,Friedmann G, Promper CH et al. (1986) Experimental MR studies with fast imaging sequences (FFE) at 1.5 T: signal contrast in normal and pathological tissues. Radiology 161 (P): 333
Laniado M, Kornmesser W, Deimling M, Felix R (1986) Dynamic MR imaging of renal tumors: fast imaging and Gd-DTPA. Radiology 161 (P): 119
Mansfield P, Morris PG (1982) NMR imaging in biomedicine, suppl 2. In: Waugh JS (ed.) Advances in magnetic resonance. Academic, New York, pp 75–77
Margosian P, Deimling M (1986) Clinical tests of chemical shift imaging using fast gradient echoes. Radiology 161 (P): 211
Matthaei D, Frahm J, Haase A et al. (1986) Möglichkeiten der schnellen Kernspintomographie mit dem FLASH-Verfahren. Zentralbl Radiologie 132 (5): 358
Mills TC, Ortendahl DA, Hylton NM et al. (1987) Partial flip angle MR imaging. Radiology 162: 531–539
Oppelt A, Gaumann R, Barfuß H et al. (1986) FISP: eine neue schnelle Pulssequenz für die Kern-spintomographie. Electromed (EnglEd) 54: 15–17
Rienmüller R, Brunnhölzl W, Gärtner CH et al (1987) MR bei transplantierten Herzen. In: Lissner J, Doppman JR, Margulis A (eds) MR’87. Schnetztor Verlag, Konstanz 69–77
Schultz E, Lutz NW (1986) Gewebeäquivalente MRI-Phantommaterialien - Eigenschaften und Anwendungsmöglichkeiten. Zentralbl Radiologie 132 (5): 376
Utz JA, Herfkens R, Glover GH (1986) Dynamic MRI of the heart. Radiology 161 (P): 185
Weber H, Deimling M (1987) Schnelle Bildgebung mit FISP und FLASH. Vergleich des Kontrastverhaltens und Anwendungsmöglichkeiten. In: Lissner J, Doppman JL, Margulis A (eds) MR’87, Referateband, Schnetztor (inpress)
Weber H, Purdy D, Deimling M, Oppelt A (1986a) Contrast behaviour of FLASH and FISP: results from synthetic images. Radiology 161 (P): 67
Weber H, Purdy D, Deimling M, Oppelt A (1986b) Contrast behaviour of the fast imaging sequences FLASH and FISP: results from synthetic images. Book of abstracts vol 3. Society of Magnetic Resonance in Medicine Berkeley, CA 94704, USA 957
Weiss T, Mitsch E, Laniado M et al. (1987) Schnelle Kernspintomographie. RD 1 FO 146 (2): 214–222
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1989 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Heywang, S.H., Koebrunner, G., Bauer, M.W. (1989). Analysis of the Signal Intensity of FLASH and FISP Fast-Imaging Pulse Sequences. In: Baert, A.L., Boijsen, E., Fuchs, W.A., Heuck, F.H.W. (eds) Frontiers in European Radiology. Frontiers in European Radiology, vol 6. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-74233-0_2
Download citation
DOI: https://doi.org/10.1007/978-3-642-74233-0_2
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-74235-4
Online ISBN: 978-3-642-74233-0
eBook Packages: Springer Book Archive