Summary
The assessment of endothelium-mediated modulation of coronary vasomotor tone in the intact human circulation under physiologic conditions requires very precise determination of both epicardial artery diameters, reflecting effects within the conduit vessels, as well as coronary blood flow, reflecting effects within the resistance vasculature during cardiac catherization. In the present report, the accuracy and limitations of quantitative approaches to assess arterial dimensions from coronary angiograms are discussed. Using state-of-the-art image-processing techniques and x-ray imaging, epicardial artery diameter changes within the range of 8–10% can be reliably detected by quantitative coronary angiography. In addition, advances in interventional techniques do provide a means to selectively assess intracoronary blood-flow velocities using intracoronary Doppler catheters. Combining epicardial artery diameter measurements and intracoronary blood-flow velocity parameters allows for a reasonably accurate instantaneous estimate of coronary arterial blood flow. The advantages and limitations of the intracoronary Doppler technique compared to other techniques are discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bergman SR, Fox KAA, Geltman EM, Sobel BE (1985) Positron emission tomography of the heart. Progr Cardiovasc Dis 18:165
Drexler H, Zeiher AM, Wollschläger H, Meinertz T, Just H, Bonzel T (1989) Flow-dependent coronary artery dilation in humans. Circulation 80:466–474
Ganz W, Tamura K, Marcus HS, Donoso R, Yoshida S, Swan HJC (1971) Measurement of coronary sinus blood flow by continuous thermodilution in man. Circulation 44:181
Hess OM, Felder L, Gaglione A, Buechi M, Vassalli F, Jiang Z, Grimm J, Krayenbühl HP (1991) Coronary vasomotion and coronary flow reserve during exercise. Bas Res Cardiol 86 (Suppl 2):193–201
Klocke FJ (1976) Coronary blood flow in man. Progr Cardivasc Dis 19:117
Mancini GBJ, Higgins DB (1985) Digital subtraction anigiography: a review of cardiac applications. Progr Cardiovasc Dis 18:111
Pohl U, Holtz J, Busse R, Bassenge E (1986) Crucial role of endothelium in the vasodilator response to increase flow in vivo. Hypertension 8:37–44
Reiber JHC, Kooijman CJ, Slager CJ, Gerbrands JJ, Schuurbiers JCH, Boer A den, Wijns W, Serruys PW (1984) Computer assisted analysis of the severity of obstructions from coronary cineangiograms: a methodological review. Automedica 5:219
Reiber JHC, Serruys PW, Kooijman CJ, Wijns W, Slager CJ, Gerbrands JJ, Schuurbiers JCH, Boer A den, Hugenholtz PG (1985) Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms. Circulation 71:280
Rumberger JA, Feiring AJ, Higgins CR, Lipton MJ, Ell SR, Marcus ML (1987) Use of ultrafast CT to quantitate myocardial perfusion: a preliminary report. J Am Coll Cardiol 9:59
Wilson RF, Laughlin DE, Ackell PH, Chilian WM, Holida MD, Hartley CJ, Armstrong ML, Marcus ML, White CW (1985) Transluminal subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man. Circulation 72:82
Wilson RF, White CW (1985) Intracoronary papaverine: an ideal coronary vasodilator for studies of the coronary circulation in conscious humans. Circulation 73:444
Wollschläger H, Lee P, Zeiher AM, Solzbach U, Bonzel T, Just H (1986) Derivation of spatial information from biplane multidirectional coronary angiograms. Med Progr Technol 11:57
Wollschläger H, Lee P, Zeiher AM, Solzbach U, Bonzel T, Just H (1986) Improvement of quantitative angiography by exact calculation of radiological magnification factors. In: Computers in Cardiology 1985. IEEE Computer Society Press, Washington DC, pp 483–486
Zeiher AM, Drexler H, Wollschläger H, Saurbier B, Just H (1989) Coronary vasomotion in response to sympathetic stimulation in humans: importance of the functional integrity of the endothelium. J Am Coll Cardiol 14:1181–1190
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1991 Dr. Dietrich Steinkopff Verlag GmbH & Co. KG, Darmstadt
About this paper
Cite this paper
Wollschläger, H., Zeiher, A.M., Drexler, H., Just, H. (1991). Assessment of coronary vasomotor tone in humans. In: Drexler, H., Zeiher, A.M., Bassenge, E., Just, H. (eds) Endothelial Mechanisms of Vasomotor Control. Steinkopff. https://doi.org/10.1007/978-3-642-72461-9_18
Download citation
DOI: https://doi.org/10.1007/978-3-642-72461-9_18
Publisher Name: Steinkopff
Print ISBN: 978-3-642-72463-3
Online ISBN: 978-3-642-72461-9
eBook Packages: Springer Book Archive