Diaphragmatic Myopotential Inhibition in Multiprogrammable Unipolar and Bipolar Pulse Generators

  • Conference paper
Cardiac Pacing

Summary

Diaphragmatic myopotential inhibition in multiprogrammable pacemakers was tested in 119 patients with implanted devices from six different manufacturers. There were 105 VVI pulse generators (46 bipolar and 59 unipolar) and 14 unipolar DVI pulse generators. Diaphragmatic myopotential inhibition was tested by observing the effect of a maximal deep inspiration in the supine position with the pulse generator programmed at various sensitivities. Inhibition was demonstrated in four of 46 bipolar VVI units (8.7%) and twelve of 59 unipolar VVI units (20.3%). Inhibition was also demonstrated in four of 14 unipolar DVI systems from the one manufacturer (28.6%). This form of interference appears to be a benign clinical problem and rarely if ever leads to prolonged asystole. It should be considered in the differential diagnosis of pacemaker pauses, particularly in patients with multi programmable pulse generators programmed at higher sensitivities.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Similar content being viewed by others

References

  1. Peter R, Harper R, Sloman G: Inhibition of demand pacemakers caused by potentials associated with inspiration. Brit Heart J 1976: 38,211.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  2. Barold SS, Ong LS, Falkotf MD, Heinle RA: Inhibition of bipolar demand pacemaker by diaphragmatic myopotentials. Circulation 1977: 56,679.

    Article  CAS  PubMed  Google Scholar 

  3. Baggioni, GF, Antonoli GE: Cause apparentemente insolite diinibizione dei pacemakers unipolari a domanda. G Ital Cardiol 1978: 8,61.

    CAS  PubMed  Google Scholar 

  4. El Gamal M, VanGelder B: Suppression of an extenal demand pacemaker by diaphragmatic myopotentials: a sign of electrode perforation? Pace 1979: 2, 191.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

K. Steinbach

Rights and permissions

Reprints and permissions

Copyright information

© 1983 Dr. Dietrich Steinkopff Verlag, GmbH & Co. KG, Darmstadt

About this paper

Cite this paper

Barold, S.S., Falkoff, M.D., Ong, L.S., Heinle, R.A. (1983). Diaphragmatic Myopotential Inhibition in Multiprogrammable Unipolar and Bipolar Pulse Generators. In: Steinbach, K. (eds) Cardiac Pacing. Steinkopff, Heidelberg. https://doi.org/10.1007/978-3-642-72367-4_79

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-72367-4_79

  • Publisher Name: Steinkopff, Heidelberg

  • Print ISBN: 978-3-642-72369-8

  • Online ISBN: 978-3-642-72367-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics