Abstract
In order to gain a better understanding of many diseases, such as coronary artery disease, a clinician must be able to evaluate not only coronary anatomy and ventricular functions, but also coronary blood flow. With our new digital subtraction angiography (DSA) system, PICKER/ADAC DAS 211, we have performed studies in cooperation with our department of cardiology at the Katharinenhospital in Stuttgart.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Anschutz F, Heuck F (1959) Kreislaufuntersuchungen am Menschen mit der Serienangiographie. ROFO 91: 512
Bartl R (1970) Rontgenkinematographie der Nierenarterien; Stromungsgeschwindigkeiten — Pulsationen. Dissertation, University of Munich
Boijsen E, Dahn I, Hallbrook R (1971) Hemodynamic effects of contrast medium in arteriography of legs. Acta Radiol Diagn 11: 295
Breitling G, Hiness R (1973) Probleme der Dicken- messung. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart
Brennecke R, Brown TK, Biirsch J, Heintzen PH (1977) Computerized video-image preprocessing with applications to cardioangiographic roentgen-image series. In: Nagel H-H (ed) Digitale Bildverarbeitung, Informatik Fachberichte, vol. 8. Springer, Berlin Heidelberg New York, pp 244–262
Buck J, Guhl L, Decker D, Reiser U (1983) Angio-Cine-Densitometry of renal blood circulation by ECG controlled injection. KongreBband der Arbeitstagung fur Rontgen-Kontrastmittel in der Funktionsdiagnostik. Springer, Berlin Heidelberg New York Tokyo
Buck J (1984) Angio-Cine-Densitometrie der Niere mit herzphasengesteuerter Injektion und Auswertung durch eine elektronische Datenverarbeitungsanlage. Habilitationsschrift, University of Tubingen
Buck J (1986) Angio-Cine-Densitometrie der Niere mit herzphasengesteuerter Injektion und Auswertung durch eine elektronische Datenverarbeitungsanlage. Copythek, Thieme, Stuttgart
Decker D, Roth F-J, Epple E, Allenberg J-P (1973) MeBabweichungen der Rontgen-Cine-Densitometrie, überpruft an Modellkreislaufen. Biomed Techn (Berlin) 18: 133–138
Decker D, Epple E, Polony G (1973) GefaBdensitometrie mit der Datenverarbeitungsanlage. DIR: 159
Decker D, Epple E, Becker J, Weller R (1976) MeBverfahren fur die Rontgen-Cine-Densitometrie bewegter GefaBe. Biomed Techn (Berlin) 21: 179–185
Decker D, Faust U, Heuck F (1980) Hydraulischer Hochdruckinjektor mit digitalem Hochdruckpro- zessor. Biomed Techn (Berlin) 25: 58–62
Deininger HK (1973) MeBergebnisse an der arteriellen Nierenstrombahn. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart, pp 196–205
Deininger HK, Heuck F (1969) Der EinfluB von aberrierenden GefaBen auf das Isotopennephrogramm. ROFO 111: 397
Deininger HK (1976) Angiographisch-densitometrische Moglichkeiten zur Bestimmung der renalen Hamodynamik. Med Welt 27, 38: 1764–1770
Deininger HK, Heuck F, Vanselow K (1971) Ergebnisse der Kinedensitometrie der Nierendurchblutung. Rontgenblatter 24: 361–365
Foerster J, Link DP, Lantz BMT, Lee G, Holcroft JW, Mason DT (1981) Measurement of coronary reactive hyperemia during clinical angiography by video dilution technique. Acta Radiol 22: 209
Gould KL, Lipscomb K, Hamilton GW (1974) Physiologic basis for assessing critical coronary stenosis: instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 33: 87
Harrison DG, White CW, Hiratzka LF, Doty DB, Barnes DH, Eastham CL, Marcus ML (1984) The value of lesion cross-sectional are determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending arterial stenoses. Circulation 69: 1111
Heintzen P, Malercyk V, Pilarcyk J (1971) Neue Verfahren zur Videodensitometrie und Videometrie. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart
Heuck F, Anschutz F (1962) Wert der Serienangiographie bei Minderdurchblutung der unteren Extremitaten. Radiol Diagn (Berl) 3: 111–117
Heuck F, Vanselow K (1971) Die radiologisch- densitometrische Analyse der Blutstromung und Ge- websdurchblutung. Biomed Techn (Berlin) 16: 51–58
Heuck F, Deininger KH, Vanselow K (1970) Ergebnisse der Rontgenkinedensitometrie der Organdurchblutung. Rontgenblatter 23: 593–598
Heuck F (1973) Densitometrie in der Radiologic. Thieme, Stuttgart
Hodgson JM, Mancini GBJ, LeGrand V, Vogel RA Characterization of changes in coronary blood flow during the first six seconds after intracoronary contrast injection. Invest Radiol (in press)
Hodgson JM, LeGrand V, Bates ER, Mancini GBJ, Aueron FM, O’Neill WW, Simon SB, Beauman GJ, LeFree MT, Vogel RA (1985) Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization. Am J Cardiol 55: 188
Hoffmann JIE (1984) Maximal coronary flow and the concept of vascular reserve. Circulation 70: 153
Hohne KH, Nicolae G, Pfeiffer G, Dix WR, Ebenritter W, Novak D, Bohm M, Sonne B, Biicheler E (1977) A computerized system for angiodensitometry. X IV International Congress of Radiology, Rio de Janeiro
Klocke FJ (1983) Measurements of coronary blood flow and degree of stenosis: current clinical implications and continuing uncertainties. J Am Coll Cardiol 1: 31
Anschutz F, Heuck F (1959) Kreislaufuntersuchungen am Menschen mit der Serienangiographie. ROFO 91: 512
Bartl R (1970) Rontgenkinematographie der Nierenarterien; Stromungsgeschwindigkeiten — Pulsationen. Dissertation, University of Munich
Boijsen E, Dahn I, Hallbrook R (1971) Hemodynamic effects of contrast medium in arteriography of legs. Acta Radiol Diagn 11: 295
Breitling G, Hiness R (1973) Probleme der Dicken- messung. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart
Brennecke R, Brown TK, Biirsch J, Heintzen PH (1977) Computerized video-image preprocessing with applications to cardioangiographic roentgen- image series. In: Nagel H-H (ed) Digitale Bildverar- beitung, Informatik Fachberichte, vol. 8. Springer, Berlin Heidelberg New York, pp 244–262
Buck J, Guhl L, Decker D, Reiser U (1983) Angio-Cine-Densitometry of renal blood circulation by ECG controlled injection. KongreBband der Arbeitstagung fur Rontgen-Kontrastmittel in der Funktionsdiagnostik. Springer, Berlin Heidelberg New York Tokyo
Buck J (1984) Angio-Cine-Densitometrie der Niere mit herzphasengesteuerter Injektion und Auswertung durch eine elektronische Datenverarbeitungsanlage. Habilitationsschrift, University of Tubingen
37.Buck J (1986) Angio-Cine-Densitometrie der Niere mit herzphasengesteuerter Injektion und Auswertung durch eine elektronische Datenverarbeitungs-anlage. Copythek, Thieme, Stuttgart
Decker D, Roth F-J, Epple E, Allenberg J-P (1973) MeBabweichungen der Rontgen-Cine-Densitometrie, überpruft an Modellkreislaufen. Biomed Techn (Berlin) 18: 133–138
Decker D, Epple E, Polony G (1973) GefaBdensitometrie mit der Datenverarbeitungsanlage. DIR: 159
Decker D, Epple E, Becker J, Weller R (1976) MeBverfahren fur die Rontgen-Cine-Densitometrie bewegter GefaBe. Biomed Techn (Berlin) 21: 179–185
Decker D, Faust U, Heuck F (1980) Hydraulischer Hochdruckinjektor mit digitalem Hochdruckprozessor. Biomed Techn (Berlin) 25: 58–62
Deininger HK (1973) MeBergebnisse an der arteriellen Nierenstrombahn. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart, pp 196–205
Deininger HK, Heuck F (1969) Der EinfluB von aberrierenden GefaBen auf das Isotopennephrogramm. ROFO 111: 397
Deininger HK (1976) Angiographisch-densitometrische Moglichkeiten zur Bestimmung der renalen Hamodynamik. Med Welt 27, 38: 1764–1770
Deininger HK, Heuck F, Vanselow K (1971) Ergebnisse der Kinedensitometrie der Nierendurchblutung. Rontgenblatter 24: 361–365
Foerster J, Link DP, Lantz BMT, Lee G, Holcroft JW, Mason DT (1981) Measurement of coronary reactive hyperemia during clinical angiography by video dilution technique. Acta Radiol 22: 209
Gould KL, Lipscomb K, Hamilton GW (1974) Physiologic basis for assessing critical coronary stenosis: instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol 33: 87
Harrison DG, White CW, Hiratzka LF, Doty DB, Barnes DH, Eastham CL, Marcus ML (1984) The value of lesion cross-sectional are determined by quantitative coronary angiography in assessing the physiologic significance of proximal left anterior descending arterial stenoses. Circulation 69: 1111
Heintzen P, Malercyk V, Pilarcyk J (1971) Neue Verfahren zur Videodensitometrie und Videometrie. In: Heuck F (ed) Densitometrie in der Radiologic. Thieme, Stuttgart
Heuck F, Anschutz F (1962) Wert der Serienangiographie bei Minderdurchblutung der unteren Extremitaten. Radiol Diagn (Berl) 3: 111–117
Heuck F, Vanselow K (1971) Die radiologischdensitometrische Analyse der Blutstromung und Gewebsdurchblutung. Biomed Techn (Berlin) 16: 51–58
Heuck F, Deininger KH, Vanselow K (1970) Ergebnisse der Rontgenkinedensitometrie der Organdurchblutung. Rontgenblatter 23: 593–598
Heuck F (1973) Densitometrie in der Radiologic. Thieme, Stuttgart
Hodgson JM, Mancini GBJ, LeGrand V, Vogel RA Characterization of changes in coronary blood flow during the first six seconds after intracoronary contrast injection. Invest Radiol (in press)
Hodgson JM, LeGrand V, Bates ER, Mancini GBJ, Aueron FM, O’Neill WW, Simon SB, Beauman GJ, LeFree MT, Vogel RA (1985) Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization. Am J Cardiol 55: 188
Hoffmann JIE (1984) Maximal coronary flow and the concept of vascular reserve. Circulation 70: 153
Hohne KH, Nicolae G, Pfeiffer G, Dix WR, Ebenritter W, Novak D, Bohm M, Sonne B, Biicheler E (1977) A computerized system for angiodensitometry. X IV International Congress of Radiology, Rio de Janeiro
Klocke FJ (1983) Measurements of coronary blood flow and degree of stenosis: current clinical implications and continuing uncertainties. J Am Coll Cardiol 1: 31
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1987 Springer-Verlag Berlin, Heidelberg
About this paper
Cite this paper
Buck, J. (1987). Blood Flow Measurements with Digital Arteriography. In: Heuck, F.H.W., Donner, M.W. (eds) Radiology Today. Radiology Today, vol 4. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-71285-2_8
Download citation
DOI: https://doi.org/10.1007/978-3-642-71285-2_8
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-71287-6
Online ISBN: 978-3-642-71285-2
eBook Packages: Springer Book Archive