Skip to main content

Rheologische Wirksamkeit von Venoruton® bei Ex-vivo-Gabe zu pathologisch veränderten Bluten

Rheological Effect of Venoruton® on Pathologically Altered Blood After Ex Vivo Treatment

  • Conference paper
O-(β-Hydroxyethyl)-rutoside

Summary

Recently one recognized that blood flow strongly depends on the viscosity of blood when the vasomotoric reserve is exhausted. So an increased viscosity of the blood can lead to a stasis of blood in the microcirculation. Finally stain will cause necrosis of the tissue. There are numerous therapeutical possibilities today to influence the fluidity of blood. Therefore the rheological efficiency of Venoruton® was studied. For this purpose blood of healthy volunteers was treated with 5 mmol/1 calcium (Ca2+). When 1 µmol/1 Venoruton® were added a significant improvement of the fluidity of blood could be demonstrated. In some cases the blood of patients with reduced blood circulation showed an improved fluidity after adding in vitro the same concentration of Venoruton®.

Zusammenfassung

In zunehmendem Maße gewinnt die Erkenntnis an Bedeutung, daß der Blutfluß bei Erschöpfung der vasomotorischen Reserve von der Zähigkeit des Blutes selbst abhängt. Eine Zunahme der Zähigkeit kann somit leicht eine Stase des Blutes im Bereich der Endstrombahn verursachen. Dies führt letztlich zu Parenchymuntergängen. Es gibt heute zahlreiche Möglichkeiten, die Fließfähigkeit des Blutes therapeutisch zu beeinflussen. Deshalb wurde die rheologische Wirksamkeit von Venoruton® untersucht. Hierzu wurden Blute gesunder Spender mit 5 mmol/l Kalzium gestreßt. Bei vorheriger Zugabe von 1 µmol/1 Venoruton® konnte eine signifikante Verbesserung der Fließfähigkeit nachgewiesen werden. Gleichfalls konnte nach Zugabe der gleichen Konzentration zu entnommenem Blut vom Patienten mit Durchblutungseinschränkungen in einigen Fällen eine verbesserte Fließfähigkeit beobachtet werden.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 54.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 69.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Literatur

  1. Chien S (1972) The present state of blood rheology. In: Messmer K, Schmid-Schönbein H (eds) Hemodilution. Theoretical Basis and Clinical Application. Karger, Basel New York, pp 1–40

    Google Scholar 

  2. Dintenfass L (1971) Blood microrheology: Viscosity factors in blood flow, ischaemia and thrombosis. Butterworth, London

    Google Scholar 

  3. Harkness J (1963) A new instrument for the measurement of plasmaviscosity. Lancet 2: 280

    Article  PubMed  CAS  Google Scholar 

  4. Kiesewetter H, Dauer U, Gesch M, Seiffge D, Angelkort B, Schmid-Schönbein H (1981) A method for the measurement of the red blood cell deformability. Scand J Clin Lab Invest 41 Suppl 156: 229–233

    Article  Google Scholar 

  5. Kiesewetter H, Jung F, Lazar H, Schmid-Schönbein H (to be published) HEAM (Hematocrit Erythrocyte Aggrego-Meter) A new apparatus to measure hematocrit and extent of erythrocyte aggregation simultaneously. Microcirculation: clinical and experimental

    Google Scholar 

  6. Kiesewetter H, Radtke H, Schmid-Schönbein H (1981) The yield stress of blood in branched models of the microcirculation. Effect of hematocrit and plasma macromolecules. In: Schmid- Schönbein H, Messmer K, Rieger S (eds) Hemodilution and flow improvement. Karger, Basel, New York (Bibl Haematologica No. 47, pp 14–21

    Google Scholar 

  7. Kiesewetter H (1982) Neue rheologische Techniken und ihre Anwendung in Modellversuchen zur Simulation von Hypoperfusionszuständen bei pathologisch veränderten Bluten. Habilitationsschrift, RWTH Aachen

    Google Scholar 

  8. Kiesewetter H, Radtke H, Jung F, Schmid-Schönbein H (1982) Determination of yield point: Methods and Review. Biorheology 19: 363–374

    PubMed  CAS  Google Scholar 

  9. Krogh A (1922) The anatomy and physiology of capillaries. Yale University Press, Newhaven

    Google Scholar 

  10. Landis EM (1934) Capillary pressure and capillary permeability. Physiol Rev 14: 404

    Google Scholar 

  11. Radtke H (1982) Bestimmung der Fließschubspannung an Vollblut und Erythrozytensuspensionen in einem neuartigen Kapillarviskosimeter mit y-förmiger Verzweigung. Dissertation, RWTH Aachen

    Google Scholar 

  12. Schmid-Schönbein H (1976) Microrheology of erythrocytes, blood viscosity, and the distribution of blood flow in the microcirculation. Int Rev Physiol II (9): 1–62

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1983 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Kiesewetter, H., Radtke, H., Jung, F., Schneider, R. (1983). Rheologische Wirksamkeit von Venoruton® bei Ex-vivo-Gabe zu pathologisch veränderten Bluten. In: Voelter, W., Jung, G. (eds) O-(β-Hydroxyethyl)-rutoside. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-68969-7_4

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-68969-7_4

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-12196-1

  • Online ISBN: 978-3-642-68969-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics