Clinical Complications Due to Pacemaker System Failures and their Management

  • Chapter
Engineering in Medicine

Abstract

Patients with bradyarrhythmias have had a much improved prognosis since the introduction of electrical stimulation of the heart. However, because many problems occur related to the use of pacemaker therapy, the results of pacing depend heavily on the general condition of the patient, his cardiac status, and the quality of follow-up. Early diagnosis and treatment of complications and pacing failures by consistent and thorough follow-up are among the main factors for successful, long-term results(11,13).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. H.J. Bisping, W. Irnich, J. Meyer and S. Effert, “Störbeeinflussung implantierter Schrittmacher im Alltag”, Dtsch. med. Wschr. 97, 1773 (1972)

    Google Scholar 

  2. R. Blaser, H. Dittrich, U. Kirsch und M. Schaldach, “Elektromagnetische Felder als Gefahrenquelle für Schrittmacherpatienten”, Dtsch. med. Wschr. 97, 559 (1972)

    Article  Google Scholar 

  3. R. Blaser, H. Dittrich, U. Kirsch und M. Schaldach, “Störempfindlichkeit implantierter Herzschrittmacher”, Biomed. Technik 17, 109 (1972)

    Article  Google Scholar 

  4. N. Bleese, P. Kalmar, H. Harms, G. Rodewald und K.W. Westermann, “Implanted cardiac pacemakers; clinical experience and evaluation”, Med. Progr. Technol. 1, 69 (1972)

    Google Scholar 

  5. E. Carlens, L. Johansson, I. Karlöf, and H. Lagergren, “New method for atrial-triggered pacemaker treatment without thoracotomy”, J. thorac. cardiovasc. Surg. 50, 229 (1965)

    Google Scholar 

  6. H. Dittrich, “Die Beeinflussung synchronisierter Schrittmacher durch elektrische und impulsförmige hohe Magnetfelder”, Thoraxchirurgie 17, 547 (1969)

    Google Scholar 

  7. S. Furman and J.B. Schwedel, “An intracardiac pacemaker for Stokes-Adams seizures”, N. Engl. J. Med. 261, 943 (1959)

    Article  Google Scholar 

  8. N. Heinz, “Untersuchungen der refraktären, supernormalen und vulnerablen Phase des Herzens an Patienten mit bradykarden Rhythmusstörungen”, Arch. Kreislaufforschg. 67, 201 (1972)

    Article  Google Scholar 

  9. P. Kalmar, “Permanente synchronisierte Elektrostimulation des Herzens bei bradykarden Störungen”, Habil.-Schrift Hamburg 1969

    Google Scholar 

  10. P. Kalmar, “Fremdkörperinfektionen in der Herz-und Gefäßchirurgie”, Med. Mittlg. (Melsungen) 47, 325 (1973)

    Google Scholar 

  11. P. Kalmar, O. Giebel, G. Lotzin, K.D. Scheppokat und K.W. Westermann, “Technische und biologische Störungen bei Dauerbehandlung mit künstlichen Herzschrittmachern”, Verhdlg. Dtsch. Ges. Kreislaufforschg. 33. Tg. 165 (1967)

    Google Scholar 

  12. U. Kirsch, P. Kalmar und G. Lutz, “Über ein implantierbares Verbindungsstück für Schrittmacherkabel”, Thoraxchirurgie 18, 152 (1970)

    Google Scholar 

  13. U. Kirsch, P. Kalmar, G. Rodewald und K.W. Westermann, “Spätkomplikationen der Herzschrittmachertherapie und ihre Behandlung”, Langenbecks Arch. Chir. 329, 595 (1971)

    Article  Google Scholar 

  14. H. Lagergren and L. Johansson, “Intracardiac stimulation for complete heartblock”, Acta chir. scand. 125, 562 (1963)

    Google Scholar 

  15. D. Mymin, T.E. Cuddy, S.N. Sinha, and D.A. Winter, “Inhibition of demand pacemakers by skeletal muscle potentials”, J. Amer. Med. Ass. 223, 527 (1973)

    Article  Google Scholar 

  16. R.S. Ormond, M. Rubenfire, and D.T. Anbe, “Radiographic demonstration of myocardid penetration of permanent endocardial pacemakers”, Radiology 98, 35 (1971)

    Article  Google Scholar 

  17. T.E. Palmer, A.J. Finestone, and J. Leary, “Pacemaker induced diaphragmatic contractions”, J. Amer. Med. Ass. 200, 1179 (1967)

    Article  Google Scholar 

  18. V. Parsonnet, I.R. Zucker, L. Gilbert, and G.H. Myers, “Clinical use of an implantable standby pacemaker”, J. Amer. Med. Ass. 196, 784 (1966)

    Article  Google Scholar 

  19. H.P. Richter v. Arnauld und K.W. Westermann, “Paroxysmale ventrikuläre Tachykardien und asystolische Adams-Stokes-Anfälle durch Bruch einer Schrittmacherelektrode”, Zschr. Kardiol. 63, 390 (1974)

    Google Scholar 

  20. H.P. Richter v.Arnauld, E. Thiem und K.W. Westermann. Westermann, “Interferenzprobleme bei der Schrittmacherbehandlung”, Med. Klin. 69, 1500 (1974)

    Google Scholar 

  21. G. Rodewald, O. Giebel, H. Harms und K.D. Scheppokat, “Vorteile und Probleme der Anwendung vorhofgesteuerter Schrittmacher”, Langenbecks Arch. klin. Chir. 313, 600 (1965)

    Article  Google Scholar 

  22. G. Rodewald, O. Giebel, H. Harms, P. Kalmar und K.-D. Scheppokat, “Elektrostimulation des Herzens bei Bedarf”, Langenbecks Arch. kiln. Chir. 316, 882 (1966)

    Article  Google Scholar 

  23. H.J. Wanjura, “Möglichkeit zur Überwachung implantierter Schrittmacher”, diagnostik 2, 455 (1969)

    Google Scholar 

  24. K.W. Westermann, O. Giebel, P. Kalmar und F. Saborowski, “Funktionsstörungen und ihre Erkennung bei implantierten Schrittmachern”, 69. Tg. Nordwestdtsch. Ges. Innere Medizin 1967

    Google Scholar 

  25. K.W. Westermann, O. Giebel, P. Kalmar, G. Priester und K.D. Scheppokat, “Das Verhalten der elektrischen Reizschwelle bei Stimulation mit endokardialen Elektroden”, Verhdlg. Dtsch. Ges. Kreislaufforschg. 35, 259 (1969)

    Google Scholar 

  26. C.J. Wiggers, “The mechanism and nature of ventricular fibrillation”, Amer. Heart J. 20, 399 (1940)

    Article  Google Scholar 

  27. A. Wirtzfeld, M. Lampadius und E.O. Ruprecht, “Unterdrückung von Demand- Schrittmachern durch Muskelpotentiale”, Dtsch. med. Wschr. 97, 61 (1972)

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1975 Springer-Verlag Berlin-Heidelberg

About this chapter

Cite this chapter

Kalmar, P. et al. (1975). Clinical Complications Due to Pacemaker System Failures and their Management. In: Schaldach, M., Furman, S. (eds) Engineering in Medicine. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-66187-7_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-66187-7_11

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-66189-1

  • Online ISBN: 978-3-642-66187-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics