Abstract
When the nose and the upper airways are bypassed due to a tracheostomy or endotracheal tube, their normal function of heating and humidifying the inspired gases is altered. Therefore, in these situations artificial heating and humification of inspired gases is mandatory. The goal of any heating and humidification system is to provide inspired gases with a water content similar to that usually provided by the nose or the upper airways.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Shelly MP, Lloyd GM, Park GR (1988) A review of the mechanisms and methods of humidification of inspired gases. Intensive Care Med 14:1–9
Dery R, Pelletier J, Jacques A, Clovet M, Houde JJ (1967) Humidity in anesthesiology III: Heat and moisture patterns in the respiratory procedure during anesthesia with semiclosed system. Can Anaes Soc J 14:287–298
Dery R (1971) Humidity in anaesthesiology. Part IV: Determination of the alveolar humidity and temperature in the dog. Can Anaest Soc J 18:145–151
Primiano FP, Moranz ME, Montague FW, Miller RB, Sachs DPL (1984) Conditioning of inspired air by a hyroscopic condenser humidifier. Crit Care Med 8:675–678
Sessler DI, Moayeri A (1990) Skin surface warming: Heat flux and central temperature. Anesthesiology 73:218–224
Graff TD, Benson DW (1968) Systemic and pulmonary changes with inhaled humid atmospheres. Anesthesiology 30:199–207
Bissonnette B, Sessler DI, LaFlamme P (1989) Intraoperative temperature monitoring sites in infants and children and the effect of inspired gas warming on esophageal temperature. Anesth Analg 69:192–196
Stone DR, Downs JB, Paul WL, Perkins HM (1981) Adult body temperature and heated humidification of anesthetic gases during general anesthesia. Anesth Analg 60:736–741
Gentilello LM, Pierson DJ (2001) Trauma critical care. Am J Respir Crit Care 163:604–607
Marfatia S, Donahue PK, Hendren WH (1975) Effect of dry and humidified gases on the respiratory epithelium in rabbits. J Paediatr Surg 10:583–592
Fonkalsrud EW, Calmes S, Barciff LT, Borret CT (1980) Reduction of operative heat loss and pulmonary secretions in neonates by use of heated and humidified anesthetic gases. J Thorac Cardiovasc Surg 80:718–723
Kleeman PP (1994) Humidity of anaesthetic gases with respect to low flow anesthesia. Anaesth Intensive Care 22:396–408
Sleigh MA, Blake JR, Liron N (1988) State of the art: the propulsion of mucus by cilia. Am Rev Respir Dis 137:726–741
Gawley TH, Dundee W (1981) Attempts to reduce respiratory complications following upper abdominal operations. Br J Anaesth 53:1073–1077
Williams RB (1998) The effects of excessive humidity. Respir Care Clin North Am 2:215–228
Klein EF, Groves SA (1974) A hot pot tracheitis. Chest 65:225–226
Tsuda T, Noguchi H, Takumi Y, Aochi O (1977) Optimum humidification of air administered to a tracheostomy in dogs. Scanning electron microscopy and surfactant studies. Br J Anaesth 49:965–977
Chatburn RRT, Primiano FP (1987) A rational basis for humidity therapy. Respiratory Care 4:249–254
Johnson JW, Permutt S, Sipple JH, Salem ES (1963) Effect of intra-alveolar fluid on pulmonary surface tension properties. J Appl Physiol 19:769–785
American National Standards Institute (1979) Z79.9: Humidifiers and Nebulizers for Medical Use. ANSI, Washington
British Standards Institution (1970) BS 4494: Specifications for Humidifiers for Use with Breathing Machines. BSI, London
Kanute PR, Youtsey JW (1981) Respiratory Patient Care. Prentice Hall, Englewood Cliffs, pp 46–60
Martin C, Papazian L, Perrin G, Bantz P, Gouin F (1992) Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation >10 L/min. Chest 102:1347–1350
Unal N, Kanhai JKK, Buijk SLCE, et al (1988) A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings. Intensive Care Med 24:138–146
Stoutenbeek CH, Miranda D, Zandstra D (1982) A new hygroscopic condenser humidifier. Intensive Care Med 8:231–234
Cohen IL, Weinberg PF, Fein A, Rowinski GS (1988) Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unit. Crit Care Med 3:277–279
Roustan JP, Kienlen J, Aubas P, Aubas S, Cailar J (1992) Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation. Intensive Care Med 18:97–100
Martin C, Thomachot L, Quinio B, Viviand X, Albanese J (1995) Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Chest 107:1411–1415
Jackson C, Webb AR (1992) An evaluation of the heat and moisture exchange performance of four ventilator circuit filters. Intensive Care Med 18:264–268
Pelosi P, Croci M, Solca M (1994) Use of heat and moisture exchangers in mechanically ventilated patients. In: Vincent JL (ed) Yearbook of Intensive Care and Emergency Medicine, Springer, Heidelberg, pp 545–553
Mebius C (1983) A comparative evaluation of disposable humidifiers. Acta Anesthesiol Scand 27:403–409
Chiaranda M, Verona L, Pinamonti O, Dominioni L, Minoja G, Conti G (1993) Use of heat and moisture (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance. Intensive Care Med 19:462–466
Le Bourdelles G, Mier L, Fiquet B, et al (1996) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest 110:1294–1298
Conti G, De Blasi A, Rocco M, et al (1990) Effect of heat-moisture exchangers on dynamic hyperinflation of mechanically ventilated COPD patients. Intensive Care Med 16:441–443
Tobin M (1994) Technical aspects of the patient ventilator interface. In: Tobin MJ (ed) Principles and Practice of Mechanical Ventilation. McGraw-Hill, New York, pp 1039–1065
Pelosi P, Solca M, Ravagnan I, Tubiolo D, Ferrario L, Gattinoni L (1996) Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure support ventilation in acute respiratory failure. Crit Care Med 24:1184–1188
Iotti GA, Olivei MC, Braschi A (1999) Mechanical effects of heat moisture exchangers in ventilated patients. Crit Care 3:R77–R82
Dreyfuss D, Djedaini K, Gros I, et al (1995) Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patients colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 151:986–992
Thomachot L, Vialter R, Arnaud S, Barberon B, Nguyen AM, Martin C (1999) Do the components of heat and moisture exchangers filters affect their humidifying efficacy and the incidence of nosocomial pneumonia. Crit Care Med 27:923–928
Boots RJ, Howe S, George N, Harris FM, Faoagali J (1997) Clinical utility of hygroscopic heat and moisture exchangers in intensive care patients. Crit Care Med 25:1707–1712
Markowics P, Ricard JD, Dreyfuss D, et al (2000) Safety, efficacy, and cost effectiveness of mechanical ventilation with humidifying filters changed every 48 hours: a prospective, randomized study. Crit Care Med 28:665–671
Djedaini, Billiard M, Mier L, et al (1995) Changing heat and moisture exchangers every 48 hours rather than 24 hours does not affect their efficacy and the incidence of nosocomial pneumonia. Am J Respir Crit Care Med 152:1562–1569
Ricard JD, Le Miere E, Markowics P, et al (2000) Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week. Am J Respir Crit Care Med 161:104–109
Poulton TJ, Downs JB (1981) Humidification of rapidly flowing gas. Crit Care Med 9:59–63
Miyao H, Hirokawa T, Miyasaka K, Kawazoe T (1992) Relative humidity, not absolute humidity, is of great importance when using a humidifier with a heating wire. Crit Care Med 20:674–679
Kapadio F, Shelly MP, Anthony JM, Park GR (1992) An active heat and moisture exchanger. B J Anaesth 69:640–642
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Chiumello, D., Pelosi, P., Gattinoni, L. (2002). Conditioning of Inspired Gases in Mechanically Ventilated Patients. In: Vincent, JL. (eds) Yearbook of Intensive Care and Emergency Medicine 2002. Yearbook of Intensive Care and Emergency Medicine 2002, vol 2002. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-56011-8_25
Download citation
DOI: https://doi.org/10.1007/978-3-642-56011-8_25
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-43149-7
Online ISBN: 978-3-642-56011-8
eBook Packages: Springer Book Archive