Zusammenfassung
Die computergestützte Chirurgie ist am Ende der 80er-Jahre mit der stereotaktischen Neurochirurgie eingeführt worden [13]. Ziele dieser neuen Technik waren erhöhte Präzision, weniger Invasivität und verbesserte Rückverfolgbarkeit der Operation.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
Literatur
Aglietti P, Buzzi R (1988) Posteriorly stabilized total condylar knee replacement: three to eight years follow up of 85 knees. J Bone Joint Surg 70B: 211–216
Bargren JH, Blaha JD, Freeman MAR (1983) Alignment in total knee arthroplasty: Correlated biomechanical and clinical observations. Clin Orthop 173: 178–183
Boisrenoult P, Scemama P, Fallet L, Beaufils P et le groupe BIOMED (2001) La torsion epiphysaire distale du femur dans le genou arthrosique. Etude tomodensitometrique de 75 genoux avec arthrose mediale. Rev Chir Orthop 87: 469–476
Delp SL, Stulberg, SD, Davies B, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop 354: 49–57
Ecker ML, Lotke PA, Windor RE, Cello JP (1987) Long term results after total condylar knee arthroplasty. Clin Orthop 216: 151–158
Hood RW, Vanni M, Insall JN (1981) The correction of knee alignment in 225 consecutive total condylar knee replacements. Clin Orthop 160: 94–105
Hsu H, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment or tibialload distribution with clinical correlation. Clin Orthop 248: 135–144
Insall JN, Scott W, Ranawat CS (1979) The total condylar knee prosthesis. A report of two hundred and twenty cases. J Bone Joint Surg 61A: 173–180
Jeffrey RS, Morris RW, Benham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg 73B: 709–714
Jenny JY, Boeri C (2001) Implantation d’une prothese totale de genou assistee par ordinateur. Etude comparative cas-temoin avec une instrumentation traditionnelle. Rev Chir Orthop 87: 645–652
Julliard R, Lavallée S, Dessenne V (1998) Computer assisted reconstruction of the anterior cruciate ligament. Clin Orthop 354: 57–64
Laskin RS (1984) Alignment in total knee replacement. Orthopaedics 7: 62–72
Lavallée S (1989) Geste médico-chirurgicaux assistés par ordinateur: application à la neurochirurgie stéréotaxique. Thèse, génie biologique et médical, Grenoble
Leitner F, Picard F, Minfelde R, Schultz HJ, Cinquin P, Saragaglia D (1997) Computer-assisted knee surgical total replacement. In “lecture note in computer science”: CURMed-MRCAS’97. Springer, Berlin Heidelberg New York Tokyo, pp 629–638
Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg 59A: 77–79
Merloz Ph, Cinquin P (1994) Geste medico-chirurgical assiste par ordinateur: application a la visee automatisee du pedicule vertebral. Etude experimentale. Rev Chir Orthop 80 (Suppl I): 124–125
Peterson TC, Engh GA (1988) Radiographic assessment of knee alignment after total knee arthroplasty. J Arthroplasty 3: 67–72
Picard F, Leitner F, Saragaglia D, Cinquin P (1997) Mise en place d’une prothèse totale du genou assistée par ordinateur: A propos de 7 implantations sur cadavre. Rev Chir Orthop 83 (Suppl II): 31
Ranawat CS, Boachie-Adjei O (1988) Survivorship analysis and results of total condylar knee arthroplasty. Clin Orthop 226: 6–13
Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement: its effects on survival. Clin Orthop 299: 153–157
Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Mise en place des prothèses totale du genou assistée par ordinateur: comparaison avec la technique conventionnelle. Apropos d’une étude prospective randomisée de 50 cas. Rev Chir Orthop 87: 18–28
Tew M, Waugh W (1985) Tibial-femoral alignment and the results of knee replacement. Bone Joint Surg 67B: 551–556
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2003 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Saragaglia, D., Picard, F. (2003). Computergestützte Implantation von Knietotalendoprothesen ohne präoperative bildgebende Verfahren: Das kinematische Modell. In: Konermann, W., Haaker, R. (eds) Navigation und Robotic in der Gelenk- und Wirbelsäulenchirurgie. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-55784-2_24
Download citation
DOI: https://doi.org/10.1007/978-3-642-55784-2_24
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-62799-6
Online ISBN: 978-3-642-55784-2
eBook Packages: Springer Book Archive