Skip to main content

Tracer Kinetic Modelling

  • Chapter
  • First Online:
Book cover PET and SPECT in Neurology
  • 2484 Accesses

Abstract

This chapter provides an overview of the basic principles of quantification of cerebral PET studies using compartmental modelling. Both single- and two-tissue compartment models are presented with emphasis on volume of distribution and non-displaceable binding potential as outcome measures. Next, both full and simplified reference tissue models are introduced, obviating the need for arterial cannulation. Finally, a brief overview is given of various parametric methods enabling calculations at a voxel level.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 229.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 299.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Blomqvist G (1984) On the construction of functional maps in positron emission tomography. J Cereb Blood Flow Metab 4:629–632

    Article  CAS  PubMed  Google Scholar 

  • Boellaard R, Van Lingen A, Van Balen SCM et al (2001) Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET. Eur J Nucl Med 28:81–89

    Article  CAS  PubMed  Google Scholar 

  • Buchert R, Thiele F (2008) The simplified reference tissue model for SPECT/PET brain receptor studies. Interpretation of its parameters. Nuklearmedizin 47:167–174

    CAS  PubMed  Google Scholar 

  • Crone C (1963) The permeability of capillaries in various organs as determined by use of the ‘indicator diffusion’ method. Acta Physiol Scand 58:292–305

    Article  CAS  PubMed  Google Scholar 

  • Cunningham VJ (1985) Non-linear regression techniques in data analysis. Med Inform 10:137–142

    Article  CAS  Google Scholar 

  • Farde L, Eriksson L, Blomquist G et al (1989) Kinetic analysis of central [11C]raclopride binding to D2-dopamine receptors studied by PET – A comparison to the equilibrium analysis. J Cereb Blood Flow Metab 9:696–708

    Article  CAS  PubMed  Google Scholar 

  • Frackowiak RSJ, Lenzi GL, Jones T et al (1980) Quantitative measurement of regional cerebral blood flow and oxygen metabolism in man, using 15O and positron emission tomography: theory, procedure, and normal values. J Comput Assist Tomogr 4:727–736

    Article  CAS  PubMed  Google Scholar 

  • Gunn RN, Lammertsma AA, Hume SP et al (1997) Parametric imaging of ligand-receptor binding in PET using a simplified reference region model. Neuroimage 6:279–287

    Article  CAS  PubMed  Google Scholar 

  • Gunn RN, Gunn SR, Cunningham VJ (2001) Positron emission tomography compartmental models. J Cereb Blood Flow Metab 21:635–652

    Article  CAS  PubMed  Google Scholar 

  • Herscovitch P, Raichle ME (1985) What is the correct value for the brain-blood partition coefficient for water? J Cereb Blood Flow Metab 5:65–69

    Article  CAS  PubMed  Google Scholar 

  • Huang SC, Phelps ME, Hoffman EJ et al (1980) Noninvasive determination of local cerebral metabolic rate of glucose in man. Am J Physiol 238:E69–E82

    CAS  PubMed  Google Scholar 

  • Ichise M, Toyama H, Innis RB et al (2002) Strategies to improve neuroreceptor parameter estimation by linear regression analysis. J Cereb Blood Flow Metab 22:1271–1281

    Article  PubMed  Google Scholar 

  • Ichise M, Liow JS, Lu JQ et al (2003) Linearized reference tissue parametric imaging methods: application to [11C]DASB positron emission tomography studies of the serotonin transporter in human brain. J Cereb Blood Flow Metab 23:1096–1112

    Article  PubMed  Google Scholar 

  • Innis RB, Cunningham VJ, Delforge J et al (2007) Consensus nomenclature for in vivo imaging of reversibly binding radioligands. J Cereb Blood Flow Metab 27:1533–1539

    Article  CAS  PubMed  Google Scholar 

  • Jones T (1996) The role of positron emission tomography within the spectrum of medical imaging. Eur J Nucl Med 23:207–211

    Article  CAS  PubMed  Google Scholar 

  • Koeppe RA, Holthoff VA, Frey KA et al (1991) Compartmental analysis of [11C] Flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography. J Cereb Blood Flow Metab 11:735–744

    Article  CAS  PubMed  Google Scholar 

  • Lammertsma AA, Hume SP (1996) Simplified reference tissue model for PET receptor studies. Neuroimage 4:153–158

    Article  CAS  PubMed  Google Scholar 

  • Lammertsma AA, Brooks DJ, Beaney RP et al (1984) In vivo measurement of regional cerebral haematocrit using positron emission tomography. J Cereb Blood Flow Metab 4:317–322

    Article  CAS  PubMed  Google Scholar 

  • Lammertsma AA, Frackowiak RSJ, Hoffman JM et al (1989) The C15O2 build-up technique to measure regional cerebral blood flow and volume of distribution of water. J Cereb Blood Flow Metab 9:461–4707

    Article  CAS  PubMed  Google Scholar 

  • Lammertsma AA, Martin AJ, Friston KJ et al (1992) In vivo measurement of the volume of distribution of water in cerebral grey matter: effects on the calculation of regional cerebral blood flow. J Cereb Blood Flow Metab 12:291–295

    Article  CAS  PubMed  Google Scholar 

  • Lammertsma AA, Bench CJ, Hume SP et al (1996) Comparison of methods for analysis of clinical [11C]raclopride studies. J Cereb Blood Flow Metab 16:42–52

    Article  CAS  PubMed  Google Scholar 

  • Logan J, Fowler JS, Volkow ND et al (1990) Graphical analysis of reversible radio-ligand binding from time-activity measurements applied to [N-11C-methyl]-(-)-cocaine PET studies in human subjects. J Cereb Blood Flow Metab 10:740–747

    Article  CAS  PubMed  Google Scholar 

  • Logan J, Fowler JS, Volkow ND et al (1996) Distribution volume ratios without blood sampling from graphical analysis of PET data. J Cereb Blood Flow Metab 16:834–840

    Article  CAS  PubMed  Google Scholar 

  • Mintun MA, Raichle ME, Kilbourn MR et al (1984) A quantitative model for the in vivo assessment of drug binding sites with positron emission tomography. Ann Neurol 15:217–227

    Article  CAS  PubMed  Google Scholar 

  • Patlak CS, Blasberg RG, Fenstermacher JD (1983) Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J Cereb Blood Flow Metab 3:1–7

    Article  CAS  PubMed  Google Scholar 

  • Phelps ML (2004) PET: molecular imaging and its biological applications. Springer, New York

    Book  Google Scholar 

  • Phelps ME, Huang SC, Hoffman EJ et al (1979a) Validation of tomographic measurement of cerebral blood volume with C-11 labeled carboxyhaemoglobin. J Nucl Med 20:328–334

    CAS  PubMed  Google Scholar 

  • Phelps ME, Huang SC, Hoffman EJ et al (1979b) Tomographic measurement of local cerebral glucose metabolic rate in humans with (F-18)2-fluoro-2-deoxy-D-glucose: validation of method. Ann Neurol 6:371–388

    Article  CAS  PubMed  Google Scholar 

  • Renkin EM (1959) Transport of potassium-42 from blood to tissue in isolated mammalian skeletal muscles. Am J Physiol 197:1205–1210

    CAS  PubMed  Google Scholar 

  • Wu Y, Carson RE (2002) Noise reduction in the simplified reference tissue model for neuroreceptor functional imaging. J Cereb Blood Flow Metab 22:1440–1452

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Adriaan A. Lammertsma .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Lammertsma, A.A. (2014). Tracer Kinetic Modelling. In: Dierckx, R., Otte, A., de Vries, E., van Waarde, A., Leenders, K. (eds) PET and SPECT in Neurology. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-54307-4_3

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-54307-4_3

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-54306-7

  • Online ISBN: 978-3-642-54307-4

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics