Summary
Butyl-cyanoacrylate can be used as adhesive for experimental corneal wounds. If the adaptation is optimal, good results can be obtained. This optimal adaptation will in most cases be obtained only by additional sutures. By these the interval between the solution of the adhesive-membrane andformation of solid scars could be covered. Theoretically therefore a long acting adhesive would be of interest. This would probably cause more pronounced tissue reactions. If the adhesive penetrates into the tissue histotoxical reactions are seen biomicroscopical and histological.
Probably in future with plain corneal perforations, corneal incisions and in combination with a reduced number of sutures with corneal cataract incisions and keratoplasies the adhesive could be employed.
Résumé
Le collage de la cornée par le butyl-cyanoacrylate peut donner de très bons résultats dans le domaine expérimental, une parfaite coaptation des lèvres de la plaie étant cependant présumée. Une coaptation optimale ne peut vraisemblablement être obtenue que par des points de suture surajoutés, ce qui permettrait de pallier une certaine discordance entre le moment de l’expulsion de la membrane de collage et le stade de la cicatrisation ferme de la plaie. Théoriquement il serait intéressant de connâitre un produit adhésif à durée prolongée, qui pourrait cependant provoquer une réaction mésenchymale plus ou moins forte. En effet, si le produit adhésif pénètre dans les tissus, il laisse une réaction histotoxique tant au point de vue biomicroscopique qu’au opint de vue histologique.
Dans le domaine des applications pratiques on pourrait utiliser cette méthode dans les cas de perforation cornéenne, d’incision à la pique, d’incisions de cataracte et le kératoplastie (dans ces deux derniers cas en combinaisons avec un nombre réduit de sutures).
Zusammenfassung
Die Butylcyanoacrylatklebung an der Cornea — eine optimale Adaptation vorausgesetzt — kann experimentell sehr gute Resultate liefern. Optimale Adaptation kann wahrscheinlich in vielen Fällen nur durch zusätzliche Nähte erreicht werden, womit gleichzeitig eine gewisse zeitliche Diskrepanz zwischen Klebstoffmembranablösung und beginnender fester Vernarbung überbrückt werden könnte. Theoretisch wäre daher ein länger haftender Klebstoff von Interesse, der möglicherweise jedoch eine stärkere mesenchymale Reaktion hervorrufen könnte. Dringt der Klebstoff in das Gewebe ein, so läßt sich biomikroskopisch und histologisch eine nicht unerhebliche Histotoxicität nachweisen.
Als voraussichtliche Anwendungsgebiete könnten glatte Hornhautperforationen, Lanzenschnitte und in Verbindung mit einer reduzierten Zahl von Nähten corneale Starschnitte und Keratoplastiken bezeichnet werden.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Literatur
Bloomfield, S., Barnet, A. H., Kanter, Ph.: The use of Eastman 910 in ocular surgery. Amer. J. Ophthal. 55, 742–748, 946–953 (1963).
Ellis, R. A., Levine, A. M.: Experimental sutureless ocular surgery. Amer. J. Ophthal. 55, 743–741 (1963).
Haberlein, C.: Welche geschnittene oder gehauene Wunden sollen durch die Vereinigung, und welche sollen durch die Eiterung geheilt werden. Wien: Rudolph Graeffer 1787.
Heiss, W.: Gewebeklebstoffe, Applikation, Eigenschaften und Anwendungsmöglichkeiten. Melsunger med. Mitt. 42, 11–28 (1968).
Komi, T.: Verwendung einer neuen Klebepaste „Aron Alpha“in der Kataraktchirurgie. Jap. J. clin. Ophthal. 20, 171–176 (1966).
Lieb, W., Müller-Planitz, E.: Eastman 910 Monomer als Ersatz augenchirurgischen Nahtmaterials. Arch. port. Oftal. 19, 15–34 (1967).
Zehetbauer, G., Blümel, G.: Vergleichende experimentelle Untersuchungen über Schädigung der Cornea durch Cyano-Acrylatkleber. Ber. Internat. Symposion Klebstoffe in der Chirurgie 1967, S. 297–299. Wien: Wiener Med. Akademie 1968.
Dohlman, C. H., Payrau, P., Pouliquen, Y.: L’Application des lentilles de contact à l’aide de substances adhésives. Arch. Ophtal. (Paris) 28, 533–536 (1968).
Ellis, R. A.: Further studies using plastic adhesives (methyl-2-cyanoacrylate monomer) in ocular surgery. Klebestoffe in der Chirurgie. Ber. Int. Symposion, Wien 1967, S. 293–295. Gottlob, R., Hrsg. Wien: Verl. Wien. Med. Akad. 1968.
Häring, R., Mechsner, K., Vaubel, E.: Die Verklebung von Hautwunden nach Verletzungen. Med. Klin. 64, 1240–1244 (1969).
Kaufman, H. E., Gasset, A. R.: Clinical experience with the Epikeratoprothesis. Amer. J. Ophthal. 67, 38–45 (1969).
Lehmann, A. W., Hayes, G. J., Leonard, F.: Toxicity of alkyl-2-cyano-acrylates. Arch. Surg. 93, 441–446 (1966).
Lick, R. F., Brückner, W., Dietrich, K. F.: Zum nahtlosen Wundverschluß durch Kleben. Med. Klin. 62, 321–324 (1967).
Majima, A., Mizuno, K.: Use of aron alpha A in ophthalmic surgery. Jap. J. clin. Ophthal. 20, 759–769 (1966).
Refojo, M. F., Dohlman, C. H., Ahmad, B., Carrol, J. M., Allen, J. C.: Evaluation of adhesives for corneal surgery. Arch. Ophthal. 80, 645–656 (1968).
Reim, M.: Behandlung von Hornhautperforationen mit Gewebekleber. Klin. Mbl. Augenheilk. 156, 562 (1970).
Reim, M., Vogt, M.: Das Kleben von Hornhautwunden im Kaninchenversuch. Albrecht v. Graefes Arch. klin. exp. Ophthal. 179, 53 (1969).
Webster, R. G., Slansky, H. H., Refojo, M. F., Boruchoff, S. A., Dohlman, C. H.: The use of adhesive for the closure of corneal perforations. Report of two cases. Arch. Ophthal. 80, 705–709 (1968).
Zehetbauer, G., Blümel, G.: Vergleichende experimentelle Untersuchungen über die Schädigung der Cornea durch Cyanoacrylatkleber. In: Klebestoffe in der Chirurgie. Ber. Int. Symposion Wien, 1967, S. 297–299. Gottlob, R., Hrsg. Wien: Verl. Wien. Med. Akad. 1968.
Harms, H., Mackensen, G.: Augenoperationen unter dem Mikroskop, S. 40. Stuttgart: Thieme 1966.
Honegger, H.: Pers. Mitteilung.
Straub, W.: Klin. Mbl. Augenheilk. 181, 680 (1957).
Thiel, R.: Klin. Mbl. Augenheilk. 109, 89 (1943).
Harms, H., Mackensen, G.: Augenoperationen unter dem Mikroskop. Stuttgart: Thieme 1966.
Hudemann, H.: Chirurgisches Nahtmaterial, Eigenschaften, Sterilität und deren Prüfung. Jena: G. Fischer 1959.
Konzen, H., Straumann, F., Paschke, E.: Grundlagen der Alloplastik mit Metallen und Kunststoffen. Stuttgart: Thieme 1967.
Nockemann, P. F.: Die chirurgische Naht. Stuttgart: Thieme 1968.
Esslen, E., Papst, W.: Die Bedeutung der Elektromyographie für die Analyse von Motilitätsstörungen der Augen. Acta Ophthal. Suppl. 57. Basel: Karger 1961.
Huber, A.: In: Hamburger, F. A., Hollwich, F., Augenmuskellähmungen. Bücherei des Augenarztes 46, S. 75–116. Stuttgart: Enke 1966.
Papst, W.: Paralytischer Strabismus infolge paradoxer Innervation. Ber. dtsch. ophthal. Ges. 67, 84–101 (1965).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1970 J. F. Bergmann-Verlag, München
About this paper
Cite this paper
Velissaropoulos (1970). Achte wissenschaftliche Sitzung. In: Jaeger, W. (eds) Auge und Immunologie. Deutsche Ophthalmologische Gesellschaft, vol 70. J.F. Bergmann-Verlag. https://doi.org/10.1007/978-3-642-47086-8_9
Download citation
DOI: https://doi.org/10.1007/978-3-642-47086-8_9
Publisher Name: J.F. Bergmann-Verlag
Print ISBN: 978-3-8070-0278-1
Online ISBN: 978-3-642-47086-8
eBook Packages: Springer Book Archive