Abstract
Recently, THIC system has been paid more attention to and successfully commercialized. Based on the idea of THIC for air-conditioning system, there are various schemes and devices for constructing a THIC system. Application cases with various types of high-temperature cooling sources, outdoor air handling units, and indoor terminals have been discussed in literatures. This chapter focuses on some typical examples of THIC air-conditioning systems applied in commercial buildings with different functions (such as office building, hospital building, large space building, and industrial factory) that are located in different regions and corresponding to different outdoor climates.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Chen P, Liu SQ (2009) Temperature and humidity independent control air-conditioning system design for inpatient building of central hospital of Sanmenxia. Refrig Air Cond 9:66–71 (in Chinese)
Fan YY, Lv SY, Li X (2011) Temperature and humidity independent control system design of an art exhibition center. Chin HV&AC 41:39–43 (in Chinese)
Fang Y (2010) Design of temperature and humidity independent control air-conditioning system in the culture relic storeroom. In: Chinese annual HVAC symposium (in Chinese)
Hu JL (2010) Application of temperature and humidity independent control technology to the HVAC design of Expo 2010 Swedish pavilion. Chin HV&AC 40(8):96–98 (in Chinese)
Jiang Y, Zhou M, Zhang Y, Liu Y, Yan D, Gao ZH, Zhang XL (2010) A terminal used for displacement ventilation combined with radiant floor cooling system. CN201020180016.2 (Chinese Patent)
Jin Y (2007) Design for the Sino-Italian ecological and energy efficient building of Tsinghua University. Chinese HV&AC 37:73–75 (in Chinese)
Li Y, Hu R, Feng TT (2011) Application of temperature and humidity independent control air conditioning system to the second phase of Qingdao Xiangxi Villa. Chin HV&AC 41(1):42–47 (in Chinese)
Lin KP, Xu HQ, Zhou XR (2009) Design of air conditioning system for major venues of the 7th China flower exposition. Chin HV&AC 39(5):2–6 (in Chinese)
Liu XH, Li Z, Jiang Y, Lin BR (2006) Annual performance of liquid desiccant based independent humidity control HVAC system. Appl Therm Eng 26:1198–1207
Lu B, Chen M, Zhang YN (2011) Energy-saving design for air-conditioning system in ECO building. Refrig Air-Cond 11(1):77–81 (in Chinese)
Xie XY (2009) Research on indirect evaporative cooling air conditioning system. Doctoral dissertation, Tsinghua University, Beijing (in Chinese)
Xie XY, Jiang Y, Liu SQ, Qu KY, Yu XY (2007) Design and development of an indirect evaporative water chiller. Chin HV&AC 37(7):66–71 (in Chinese)
Zhang T, Liu XH, Zhang L, Jiang JJ, Zhou M, Jiang Y (2013) Performance analysis of the air-conditioning system in Xi’an Xianyang International Airport. Energy Build 59:11–20
Zhao K, Liu XH, Zhang T, Jiang Y (2011) Performance of temperature and humidity independent control air-conditioning system applied in an office building. Energy Build 43:1895–1903
Zhou M (2011) Application of independent temperature and humidity control of terminal T3A to Xi’an Xianyang International Airport. Chin HV&AC 41(11):27–30 (in Chinese)
Zhu WF, Li ZJ, Liu S, Liu SQ, Jiang Y (2010) In situ performance of independent humidity control air-conditioning system driven by heat pumps. Energy Build 42:1747–1752
Zi XQ (2007) Diagnosis of energy efficiency and study on solutions for the air conditioning of the high-rise comprehensive office building in Shenzhen. Master thesis, Chongqing University, Chongqing (in Chinese)
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Liu, X., Jiang, Y., Zhang, T. (2013). Application Cases of THIC Systems. In: Temperature and Humidity Independent Control (THIC) of Air-conditioning System. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-42222-5_8
Download citation
DOI: https://doi.org/10.1007/978-3-642-42222-5_8
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-42221-8
Online ISBN: 978-3-642-42222-5
eBook Packages: EnergyEnergy (R0)