Cataracts, which result from lens opacification, are the leading cause of blindness worldwide. Current methods for determining the severity of cataracts are based on manual assessments that may be weakened by subjectivity. In this work, we propose a system to automatically grade the severity of nuclear cataracts from slit-lamp images. We introduce a new feature for cataract grading together with a group sparsity-based constraint for linear regression, which performs feature selection, parameter selection and regression model training simultaneously. In experiments on a large database of 5378 images, our system outperforms the state-of-the-art by yielding with respect to clinical grading a mean absolute error (ε) of 0.336, a 69.0% exact integral agreement ratio (R 0), a 85.2% decimal grading error ≤ 0.5 (R e0.5), and a 98.9% decimal grading error ≤ 1.0 (R e1.0). Through a more objective grading of cataracts using our proposed system, there is potential for better clinical management of the disease.
Chapter PDF
Similar content being viewed by others
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
IAPB Report - State of the World Sight (2010), http://www.iapb.org/resource/iapb-report-state-world-sight-2010
Asbell, P.A., Dualan, I., Mindel, J., Brocks, D., Ahmad, M., Epstein, S.: Age-Related Cataract. The Lancet 365(9459), 599–609 (2005)
Chylack, L., Wolfe, J., Singer, D., Leske, M.C., Bullimore, M.A., Bailey, I.L., Friend, J., McCarthy, D., Wu, S.Y.: The Lens Opacities Classificatin System III. Arch Ophthalmology 111(6), 831–836 (1993)
Klein, B., Klein, R., Linton, K., Magli, Y., Neider, M.: Assessment of Cataracts from Photographs in the Beaver Dam Eye Study. Ophthalmology 97, 1428–1433 (1990)
Thylefors, B., Chylack Jr., L.T., Konyamia, K., Sasaki, K., Sperduto, R., Taylor, H.R., West, S.: A Simplied Cataract Grading System – The WHO Cataract Grading Group. Ophthalmic Epidemiology 9(2), 83–95 (2002)
Li, H., Lim, J.H., Liu, J., Mitchell, P., Tan, A., Wang, J., Wong, T.: A Computer-Aided Diagnosis System of Nuclear Cataract. IEEE Trans. on Biomed. Eng. 57, 1690–1698 (2010)
Foong, A., Saw, S., Loo, J., Shen, S., Loon, S., Rosman, M.: Rationale and Methodology for a Population-based Study of Eye Diseases in Malay People: The Singapore Malay Eye Study (SiMES). Ophthalmic Epidemiology 14, 25–35 (2007)
Tan, A.C.S., Wang, J.J., Lamoureux, E.L., Wong, W., Mitchell, P., Li, J., Tan, A.G., Wong, T.Y.: Cataract Prevalence Varies Substantially with Assessment Systems: Comparison of Clinical and Photographic Grading in a Population-Based Study. Ophthalmic Epidemiology 18(4), 164–170 (2011)
Fan, S., Dyer, C.R., Hubbard, L., Klein, B.: An Automatic System for Classification of Nuclear Sclerosis from Slit-lamp Photographs. In: Ellis, R.E., Peters, T.M. (eds.) MICCAI 2003. LNCS, vol. 2878, pp. 592–601. Springer, Heidelberg (2003)
Huang, W., Li, H., Chan, K.L., Lim, J.H., Liu, J., Wong, T.Y.: A Computer-Aided Diagnosis System of Nuclear Cataract via Ranking. In: Yang, G.-Z., Hawkes, D., Rueckert, D., Noble, A., Taylor, C. (eds.) MICCAI 2009, Part II. LNCS, vol. 5762, pp. 803–810. Springer, Heidelberg (2009)
Duncan, D.D., Shukla, O.B., West, S.K., Schein, O.D.: New Objective Classification System for Nuclear Opacification. Journal of Optical Society of America 14, 1197–1204 (1997)
Khu, P.M., Kashiwagi, T.: Quantitating Nuclear Opacification in Color Scheimpflug Photographs. Invest. Ophthalmol. Vis. Sci. 34, 130–136 (1993)
Fei-Fei, L., Perona, P.: A Bayesian Hierarchical Model for Learning Natural Scene Categories. In: CVPR, vol. 2, pp. 524–531 (2005)
Lowe, D.G.: Distinctive Image Features from Scale-invariant Keypoints. Int. J. Comput. Vision 60(2), 91–110 (2004)
Liu, J., Ji, S., Ye, J.: SLEP: Sparse Learning with Efficient Projections. Arizona State University (2009), http://www.public.asu.edu/~jye02/Software/SLEP
Chang, C., Lin, C.: LIBSVM: A Library for Support Vector Machines. ACM Trans. on Intel. Sys. and Tech. 2(3), 27:1–27:27 (2011)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Xu, Y. et al. (2013). Automatic Grading of Nuclear Cataracts from Slit-Lamp Lens Images Using Group Sparsity Regression. In: Mori, K., Sakuma, I., Sato, Y., Barillot, C., Navab, N. (eds) Medical Image Computing and Computer-Assisted Intervention – MICCAI 2013. MICCAI 2013. Lecture Notes in Computer Science, vol 8150. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-40763-5_58
Download citation
DOI: https://doi.org/10.1007/978-3-642-40763-5_58
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-40762-8
Online ISBN: 978-3-642-40763-5
eBook Packages: Computer ScienceComputer Science (R0)