Abstract
Wilhelm von Zehender and the court mechanic Heinrich Westien constructed the first binocular microscope in 1887, calling it a “corneal loupe” (von Zehender and Westien 1887). It was fitted with an objective and ocular providing tenfold magnification so that the anterior segments of the eye could be viewed stereoscopically. Dr. von Zehender also carried out surgery on the anterior eye using this instrument. Its height was adjustable, as was the patient’s chinrest, which stood separately. There was an “illumination lens” attached via ball joints so that light could be aimed onto the eye from different directions. This was the first binocular microscope to be used in ophthalmology (Schmidt 2001) (Fig. 6.1).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Literature
Abraham FA (1988) A device for easy slitlamp fundoscopy with a +90-diopter lens. Ophthalmologica 196:40–42
Affolter A (1917) Ophthalmoskopische Untersuchungen in rotfreiem Licht. Graefes Arch Ophthalmol 94:1–27
Allen L, Braley AE, Thorpe HE (1954) An improved gonioscopic contact prism. Arch Ophthalmol 51:451–455
Aubert H (1891) Demonstration eines binocularen Hornhautmikroskops. Tagung der Ophthalmologischen Gesellschaft Heidelberg, 21. Zusammenkunft. Klin Monatsbl Augenheilkd 29: 260–261
Axenfeld T (1900) Eine neue Westien’sche binoculare Handloupe (Brillenloupe) zum Präparieren und für klinische Zwecke, mit veränderlicher Pupillendistanz und verstellbarem Kopfhalter. Klin Monatsbl Augenheilkd 38:20–25
Barkan O (1952) Contact lenses for gonioscopy and ophthalmoscopy. Am J Ophthalmol 35:1821
Barker FM, Wing JT (1990) Ultra wide field fundus biomicroscopy with the Volk quadraspheric lens. J Am Optom Assoc 61:573–575
Berliner ML (1949) Biomicroscopy of the eye. Hoeber, New York
Birkhäuser R (1921) Eine neue Beleuchtungsvorrichtung mit Bogenlicht (Bogenlicht-Fokallampe) für die Untersuchung des vorderen Bulbusabschnittes sowie für die Ophthalmoskopie mit rotfreiem Licht. Klin Monatsbl Augenheilkd 66:240–248
Braley AE, Watzke RC, Allen L, Frazier O (1970) Stereoscopic atlas of slit-lamp biomicroscopy. The CV Mosby Company, Saint Louis
Castroviejo R (1835) Goniophotography. Photography of the angle of the anterior chamber in living animals and human subjects. Am J Ophthalmol 18:524–527
Coccius A (1853) Über die Anwendung des Augenspiegels nebst Angabe eines neuen Instrumentes. Müller, Leipzig
Comberg W (1933) Über eine neue Spaltlampe. Klin Monatsbl Augenheilkd 91:577–583
Czapski S (1899) Binoculares Cornealmikroskop. Graefes Arch Ophthalmol 48:229–235
Donaldson D (1950) A camera for stereoscopic photography of the anterior segment. Arch Ophthalmol 43:1083–1087
Doshi S, Harvey W (2005) Assessment and investigative techniques, Eye essentials. Elsevier/Butterworth Heinemann, Edinburgh
Draeger J (1973) Technischer Fortschritt bei der Kontaktglas-Untersuchung des Augenhintergrundes. Ber Dtsch Ophthalmol Ges 73:297–301. Bergmann, München
Duke-Elder S, David A (1970) System of ophthalmology, vol 5. Kimpton, London, pp 94–95
Eisner G (1973) Biomicroscopy of the peripheral fundus - An atlas and textbook. Springer, New York, Heidelberg, Berlin, pp 1–191
El Bayadi G (1953) New method of slit-lamp microscopy. Br J Ophthalmol 37:625–628
El Bayadi G (1965) Textbook of ophthalmology. Hani Printing Office, Cairo
Erggelet H (1925) Das Spaltlampengerät. Die Gullstrand’sche Spaltlampe und die Beobachtungsmittel zur Untersuchung in fokaler Beleuchtung. In: Handbuch der gesamten Augenheilkunde (begr. Graefe A, Saemisch Th) Die Untersuchungsmethoden, 3. Band, S. Springer, Berlin, pp 119–183
Evans JN (1932) Reflecting prism-lens for slit-lamp microscopy of the retina. Arch Ophthalmol 8:274–277
Faschinger C, Hommer A (2012) Gonioscopy. Springer, New York, Heidelberg, Berlin, pp 1–84
Fick EA (1888) Eine Contactbrille. Arch Augenheilkd 18:279–289
Frisen L (1972) An adjustable biomicroscopy contact glass with erect imagery. Arch Ophthalmol 87:202–205
Funder W, Rotter H (1951) Ein neues Zusatzgerät zur Untersuchung im optischen Horizontalschnitt an der Spaltlampe von Haag-Streit. Graefes Arch Ophthalmol 151:765–771
Gellrich M-M (2011a) Spaltlampenvideografie ermög-licht umfassenden Ophthalmologie-Bildatlas (Slit lamp videography makes a comprehensive ophthalmological atlas possible). Z prakt Augenheilkd 32:567–573
Gellrich M-M (2011b) Centenary of the slit lamp (1911–2011) Video presented at the conference of DOG in Berlin and at the conference of cataract and refractive surgery in Moscow 2011
Gellrich M-M (2011c) Die Spaltlampe – Konstruktionsgeschichte, Untersuchungsmethoden, Videografie. Kaden, Heidelberg, pp 1–194
Goldmann H (1933) Eine neue Spaltlampe. Klin Monatsbl Augenheilkd 91:494–502
Goldmann H (1938) Zur Technik der Spaltlampenmikroskopie. Ophthalmologica 96:90–97
Goldmann H (1949) Einige Ergebnisse der Spaltlampenuntersuchungen des Kammerwinkels und des Augenhintergrunds. Ophthalmologica 117:253–258
Goldmann H (1970) Fokale Beleuchtung. In: Die ophthalmologischen Untersuchungsmethoden (Hrsg: Straub W). Enke, Stuttgart, pp 104–230
Gullstrand A (1907) Zur Maculafrage. Graefes Arch Ophthalmol 66:141–188
Gullstrand A (1911) Demonstration der Nernst-Spaltlampe. 37. Versammlung der Ophthalmologischen Gesellschaft Heidelberg. S. 374–376. Bergmann, Wiesbaden
Gullstrand A (1912) Die Nernstspaltlampe in der ophthalmologischen Praxis. IV. Jahresversammlung des schwedischen augenärztlichen Vereins, Stockholm 1911 (translated by Fritz Ask) Klin Monatsbl Augenheilkd 50:483–484
Gullstrand A (1918) Die Macula centralis im rotfreien Lichte. Klin Monatsbl Augenheilkd 60:289–324
Heinzen H, Würth A (1959) Die Photographie des Kammerwinkels. Ophthalmologica 138:214–220
Hembold R (1910) Die Verwendung von Spektrallicht zur Augenuntersuchung. Med Klin 6:1649–1650
Henker O (1916) Ein Träger für die Gullstrandsche Nernst-Spaltlampe. Z ophthalmol Opt 4:75–85
Henker O (1920) Das vereinfachte große Gullstrand’sche Ophthalmoskop. Z ophthalmol Opt 8:108–117
Heydenreich A (1959) Untersuchungsmethoden. In: Der Augenarzt, Band 2 (Hrsg: Velhagen K) S. Thieme, Stuttgart, pp 1–146
Holland G (2004) Von der seitlich fokalen Beleuchtung zur modernen Spaltlampe. Mitteilungen der Julius Hirschberg Gesellschaft zur Geschichte der Augenheilkunde 6:53–84
Hruby K (1941) Über eine wesentliche Vereinfachung der Untersuchungstechnik des hinteren Augenabschnittes im Lichtbüschel der Spaltlampe. Graefes Arch Ophthalmol 143:224–228
Hruby K (1942) Spaltlampenmikroskopie des hinteren Augenabschnittes ohne Kontaktglas. Klin Monatsbl Augenheilkd 108:195–200
Hruby K (1950) Spaltlampenmikroskopie des hinteren Augenabschnittes. Untersuchungstechnik, Ergebnisse und praktische Bedeutung. Urban & Schwarzenberg, Wien
Kapetansky FM (1988) A bubble-free goniolens. Ophthalmic Surg 19:414–416
Kleefeld G (1937) La photographie des opacités annulaires du vitré. Bull Soc Belge Ophtalmol 75:116–118
Koby FE (1930) Slit lamp microscopy of the living eye. Churchill, London
Koeppe L (1918) Die Mikroskopie des lebenden Augenhintergrundes mit starker Vergrößerung im fokalen Lichte der Gullstrand’schen Nernstspaltlampe. 1. Mitteilung Die Theorie, Apparatur und Anwendungstechnik der Spaltlampenuntersuchung des Augenhintergrundes im fokalen Licht. Graefes Arch Ophthalmol 95:282–306
Koeppe L (1920) Die Mikroskopie des lebenden Kammerwinkels im fokalen Lichte der Gullstrandschen Nernstlampe. Graefes Arch Ophthalmol 101:48–66
Koeppe L (1922) Die Mikroskopie des lebenden Auges. Springer, Berlin
Koppenhöfer E (2011) Von der seitlichen Beleuchtung zur Spaltlampe. Ein kurzer medizinhistorischer Abriss (From Lateral Illumination to Slit Lamp — A Brief Outline of Medical History). http://de.wikipedia.org/wiki/Spaltlampe
Kroll P, Küchle M, Küchle HJ (2008) Augenärztliche Untersuchungsmethoden. Thieme, Stuttgart
Kronfeld PC, McGarry HI, Smith HE (1942) Gonioscopic studies on the canal of Schlemm. Am J Ophthalmol 25:1163–1173
Laqueur L (1887) Über Beobachtungen mittelst der Zehender-Westien’schen binocularen Cornealloupe. Klin Monatsbl Augenheilkd 25:463–478
Ledford JK, Sanders V (2006) The slit lamp primer. SLACK Incorporated, Thorofare
Lee NB (1990) Biomicroscopic examination of the ocular fundus with a +150 dioptre lens. Br J Ophthalmol 74:294–296
Lemoine V (1923) Ophtalmoscopie microscopique du fond d’oeil vivant (sans verre de contact). Bull Mem Soc Fr Ophtalmol 36:366–373
Leydhecker W (1969) Zwei Instrumente zur Goniotomie und Angulozision. Klin Monatsbl Augenheilkd 154:111–112
Littmann H (1950a) Die Theorie der stereoskopischen Fundusmikroskopie mit dem Spaltlampengerät. Graefes Arch Ophthalmol 150:539–554
Littmann H (1950b) A new slit lamp apparatus. Am J Ophthalmol 33:1863–1870
Lopez Enriquez EM (1936) Weitere Neuerungen zur Untersuchung des Augenhintergrundes mittels Spaltlampe. Klin Monatsbl Augenheilkd 96:181–182
Lopez Enriquez M (1935) Neue Zusatzeinrichtung für die Mikroskopie des lebenden Auges. Klin Monatsbl Augenheilk 95:77–79
Lundberg C (1985) Biomicroscopic examination of the ocular fundus with a +60-Diopter lens. Am J Ophthalmol 99:490–491
Mártonyi CL, Bahn CF, Meyer RF (2007) Slit lamp: examination and photography. Revised and expanded third edition. Time One Ink, Sedona
Meesmann A (1927) Die Mikroskopie des lebenden Auges an der Gullstrandschen Spaltlampe mit Atlas typischer Befunde. Urban & Schwarzenberg, Berlin
Meyner E-M (1976) Atlas der Spaltlampenphotographie – a Atlas of slit lamp photography. Ferdinand Enke, Stuttgart, pp 1–142
Michel J (1890) Lehrbuch der Augenheilkunde. Bergmann, Wiesbaden
Mizuo (1914) Ein Verfahren zur Besichtigung der Kammerbucht. (Abstract) Japan. Augenärztetagung in Tokio (1913). “Nippon Gankakai Zashi”. Klin Monatsbl Augenheilkd 52:561
Niesel P (1966) Probleme der Spaltlampenphotographie der menschlichen Linse. Doc Ophthalmol 20:131–140
Richardson KT, Shaffer RN (1965) Infant ophthalmoscopy and gonioscopy without general anesthesia. Arch Ophthalmol 73:55–57
Rosenwasser G, Tiedeman JS (1986) A stable slit lamp mounting device for 90 D lens use in non-contact ophthalmoscopy. Ophthalmic Surg 17:525
Rotter H (1955) Zur Theorie der Spaltlampenmikroskopie des Augenhintergrundes. Über die Verwendung einer Sammellinse als Vorsatzglas. Graefes Arch Ophthalmol 156:503–518
Salzmann M (1914) Die Ophthalmoskopie der Kammerbucht. Z Augenheilkd 31:1–19
Salzmann M (1915) Die Ophthalmoskopie der Kammerbucht. Z Augenheilkd 34:26–69
Schanz F (1895) Ein Hornhautmikroskop und ein Netzhautfernrohr mit conaxialer Beleuchtung. Arch Augenheilkd 31:265–272
Schanz F (1898) Demonstration eines stereoskopischen Hornhaut-Mikroskops. Tagung der Ophthalmol Gesellsch Heidelberg 27:336–338. Bergmann, München
Schlegel HJ (1969) Eine einfache Weitwinkeloptik zur spaltlampenmikroskopischen Untersuchung des Augenhintergrundes (Panfunduskop). Doc Ophthalmol 26:300–308
Schmidt TAF (1975) On slit-lamp microscopy. Doc Ophthalmol 39:117–153
Schmidt D (2001) Carl Wilhelm von Zehender (1819–1916), “Vater der Mikrochirurgie”, erster Herausgeber der Klinischen Monatsblätter für Augenheilkunde und Mitbegründer der Ophthalmologischen Gesellschaft Heidelberg. In: Mitteilungen der Julius-Hirschberg-Gesellschaft zur Geschichte der Augenheilkunde (Hrsg: Krogmann F). Königshausen & Neumann, Würzburg, pp 79–166
Schnyder WF (1921) Eine einfache Bogenspaltlampe und theoretische Ausführungen über das neue Beleuchtungsprinzip der Spaltlampe und dessen Bedeutung. Z Augenheilkd 46:328–345
Shulpina NB (1966) Биомикроскопия глаза (Biomicroscopy of the eye). Medicina, Moscow
Sickenberger W (2011) Klassifikation von Spaltlampenbefunden, DOZ
Stähli J (1915) Die Azo-Projektionslampe (Halbwatt-Lampe) der deutschen Auergesellschaft, ein Ersatz für Nernstlicht. Klin Monatsbl Augenheilkd 54:685–688
Steinvorth E, Hötte E (1959) Kammerwinkelphotographie mit der Minox-Kamera. Klin Monatsbl Augenheilkd 135:112–113
Streuli H (1920) Beleuchtungstechnik der Spaltlampe. Klin Monatsbl Augenheilkd 65:769–782
Streuli H (1921) Beleuchtungstechnik der Spaltlampe. Mitteilung über ein einfaches und praktisches Modell einer Bogenspaltlampe nebst Vorrichtung zur Ophthalmoskopie im rotfreien Licht. Klin Monatsbl Augenheilkd 66:512–524
Thiel R (1930) Photographierte Spaltlampenbilder. Tagung der Dtsch Ophthalmol Ges 48:355–357. Bergmann, München
Trantas A (1900) Moyens d’explorer par l’ophtalmoskope – et par translucidité – la partie antérieure du fond oculaire, le cercle ciliaire y compris. (Abstract) Cbl prakt Augenheilkd 24:277–278
Trantas A (1907) Ophtalmoscopie de la région ciliaire et rétrociliaire. Arch Ophtalmol (Paris) 27:581–606
Trantas A (1928) Sur la gonioscopie (Ophtalmoscopie de l’angle irido-cornéen). Arch Ophtalmol (Paris) 45:617–635
Troncoso MU (1925) Gonioscopy and its clinical applications. Am J Ophthalmol 8:433–449
van Beuningen EGA, Fischer FW (1957) Über eine Methode zur Photographie farbiger, stereoskopischer Kammerwinkelbilder. Ber Dtsch Ophthalmol Gesellsch 60. Zusammenkunft S. 291–296. Bergmann, München
Vogt A (1913a) Herstellung eines gelbblauen Lichtfiltrates, in welchem die Macula in vivo in gelber Färbung erscheint, die Nervenfasern der Netzhaut und andere feine Einzelheiten derselben sichtbar werden, und der Grad der Gelbfärbung der Linse ophthalmoskopisch nachweisbar ist. Graefes Arch Ophthalmol 84:293–311
Vogt A (1913b) Demonstration eines von Rot befreiten Ophthalmoskopierlichtes. Tagung der Ophthalmologischen Gesellschaft Heidelberg 39:416–417. Ritter, Wiesbaden
Vogt A (1920) Die Tiefenlokalisation in der Spaltlampenmikroskopie. Z Augenheilkd 43:393–402
Vogt A (1921a) Vergleichende Messungen der spezifischen Helligkeit von Nernst-Nitra- und Bogenspaltlampe bei alter und neuer Abbildungsweise. Z Augenheilkd 46:1–7
Vogt A (1921b) Atlas der Spaltlampenmikroskopie. Springer, Berlin
Vogt A (1921c) Die Reflexion der Netzhautvorderfläche im rotfreien Licht. Präretinale (superfizielle retinale) Fältchenbildung. Klin Monatsbl Augenheilkd 66:838–859
Vogt A (1925) Die Ophthalmoskopie im rotfreien Licht. In: Handbuch der gesamten Augenheilkunde (begr. Graefe A, Saemisch Th). Die Untersuchungsmethoden 3. Band. Springer, Berlin, pp 1–118
Vogt A (1930) Lehrbuch und Atlas der Spaltlampenmikroskopie des lebenden Auges mit Anleitung zur Technik und Methodik der Untersuchung. Zugleich zweite Auflage des “Atlas der Spaltlampenmikroskopie”. Erster Teil: Technik und Methodik, Hornhaut und Vorderkammer. Springer, Berlin
Vogt A (1931) Lehrbuch und Atlas der Spaltlampenmikroskopie des lebenden Auges mit Anleitung zur Technik und Methodik der Untersuchung. Zugleich zweite Auflage des “Atlas der Spaltlampenmikroskopie”. Zweiter Teil: Linse und Zonula. Springer, Berlin
Vogt A (1942) Lehrbuch und Atlas der Spaltlampenmikroskopie des lebenden Auges mit Anleitung zur Technik und Methodik der Untersuchung. Zugleich zweite, stark erweiterte Auflage des “Atlas der Spaltlampenmikroskopie”. Dritter Teil: Iris, Glaskörper, Bindehaut. Schweizer Druck- und Verlagsanstalt, Zürich
Volk D United States patent No. 4,721,378, 26 Jan 1988 (zit bei Snead et al. 1992)
von Zehender CW, Westien H (1887) Beschreibung der binocularen Cornealoupe. Klin Monatsbl Augenheilkd 25:496–499
Wegner W (1929) Demonstrationspolyophthalmoskop. Klin Monatsbl Augenheilkd 83:544–548
Wolff H (1908) Zur Photographie des menschlichen Augenhintergrunds. Arch Augenheilkd 59:115–142
Zamenhof A (1930) Ein neuer Weg zur Untersuchung des Augenhintergrundes im fokalen Licht. Graefes Arch Ophthalmol 124:87–102
Zamenhof A (1933) Die Ophthalmoskopie im fokalen und indirekten Licht. Graefes Arch Ophthalmol 129:149–190
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Gellrich, MM. (2014). History of the Slit Lamp. In: The Slit Lamp. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-39793-6_6
Download citation
DOI: https://doi.org/10.1007/978-3-642-39793-6_6
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-39792-9
Online ISBN: 978-3-642-39793-6
eBook Packages: MedicineMedicine (R0)